Compensators
-
Product
Online Dissolved Oxygen Controller
LD-LODC-A10
-
Online Dissolved Oxygen ControllerLD-LODC-A10features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
MAX Waterproof pH/ORP/Temp Logging Portable Meter
MW106
-
The Milwaukee MW106 MAX Waterproof 3-in-1 pH/OPR/Temp. Logging Portable Meter has won fans around the world with its reliable, fast and simple operation as well as its toughness and IP67 Waterproof rating. Accurate to ± 0.002 pH with automatic or manual temperature compensation, and built in GLP key. Ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
-
Product
Fiber Optic Measurement Systems & Sensors
-
MTI Instruments offers large measurement range and standoff distance fiber-optic measurement sensors and probes that provide ultra sensitive linear output response. Our modular (interchangeable) non-contact fiber optic sensors systems have dual channel that enables the user to make simultaneous measurements. Our fiber optic probes are designed to automatically compensate large changes in reflectivity making it possible to monitor dynamic reflectance of up to 100:1 making it ideal for measuring vibration of ultrasonic horns, modal analysis of disk drive suspension, displacement and timing of fuel injectors and lateral motion measurements.
-
Product
pH 5+ Handheld pH Meters
-
These meters are perfect for fast, accurate results. Automatic temperature compensation (ATC) ensures accuracy from 0 to 80°C. Meters include a protective rubber boot that also acts as a meter stand.
-
Product
K-Band Silicon SATCOM Rx Quad Core IC
AWS-0102
-
The AWS-0102 is a highly integrated silicon quad core IC intended for satellite communications applications. The device supports four dual polarization radiating elements with full programmable polarization flexibility. The device provides 22 dB of gain with a noise figure of 3.4 dB. Additional features include gain compensation over temperature and temperature reporting. The chip features ESD protection on all pins, operates from a +1.8 V supply, and is packaged in a 56 lead 7x7 mm QFN for easy installation in planar phased array antennas.
-
Product
Handheld Water Quality Meters
LAQUA PC220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Tactical Grade Inertial Measurement Unit (IMU)
ADIS16490 iSensor
-
The ADIS16490 iSensor® device is a complete inertial system that includes a triaxial gyroscope and a triaxial accelerometer. Each inertial sensor in the ADIS16490 combines industry-leading iMEMS® technology with signal conditioning that optimizes dynamic performance. The factory calibration characterizes each sensor for sensitivity, bias, alignment, and linear acceleration (gyroscope bias). As a result, each sensor has its own dynamic compensation formulas that provide accurate sensor measurements. The ADIS16490 provides a simple, cost-effective method for integrating accurate, multiaxis inertial sensing into industrial systems, especially when compared with the complexity and investment associated with discrete designs. All necessary motion testing and calibration are part of the production process at the factory, greatly reducing system integration time. Tight orthogonal alignment simplifies inertial frame alignment in navigation systems. The SPI and register structure provide a simple interface for data collection and configuration control.
-
Product
Temperature Data Acquisition
THERMES-USB
-
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
Product
Temperature compensated crystal oscillator
TCXO
-
A TCXO (Temperature compensated crystal oscillator) is a crystal oscillator with a temperature-sensitive reactance circuit in its oscillation loop to compensate the frequency-temperature characteristics inherent to the crystal unit. Epson's are classified into two types. One is a Direct-Type TCXOwith a temperature compensation circuit built into the oscillation loop. The other is an Indirect-Type TCXO with a temperature compensation circuit outside the oscillation loop, in which the oscillation frequency is therefore indirectly controlled.
-
Product
Ballast Water Monitoring Systems
-
Ballast water is essential for safe and efficient shipping operations and stabilizing steel-hulled vessels at sea. It provides a variety of critical functions, such as maintaining balance, stability, and structural integrity on non-cargo voyages or when cargo is unloaded. Ballast water is also used to compensate for fuel and water consumption during at-sea operations.
-
Product
sbRIO-9211, Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
780877-01
-
Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
Inclinometer
-
INELTA Sensorsysteme GmbH & Co. KG
*Full 0 .. 360° range*Operating temperature range -40 .. +80°C*Temperature compensated*High accuracy
-
Product
Junction Boxes
-
Junction boxes are used for complex power and signal distribution. The junction boxes have redundant mechanical barriers. The mechanical integrity of the junction box is verified during helium leak testing and hydrostatic testing of the jumper assembly. Thermal and pressure compensation is provided by the radially compliant hose or by purpose built bladder compensators, hose lengths must be sized according to the junction box internal dead volume.
-
Product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
-
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
Product
Lithography System
JetStep X500
-
The JetStep X500 panel lithography system is optimized for volume manufacturing of high-end AICS and advanced packaging panels. The system incorporates a large field exposure system with advanced features to meet the challenging requirements encountered in production of AICS or panel level packaging, such as; fine resolution to 3µm with large depth of focus (DOF), high overlay accuracy of ±1µm, automatic magnification compensation with independent x and y magnification adjustment of ±100 ppm, and automatic handling of panel substrates of various dimensions, thicknesses, and levels of warp.
-
Product
Panel-mount Type Resistivity Meter (Four-Wire Transmission)
HE-480R
-
HE-480R connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.The feature is the high-precision temperature compensation function.Its high-performance temperature compensation makes it ideal for sequential monitoring of ultra-pure water used in manufacturing processes in the semiconductor field, and many other fields, including the areas of electrical goods, foods and medicines.
-
Product
Strain Sensors
-
Columbia Research Laboratories
Columbia's foil strain sensors monitor the fatigue loading experienced by tactical aircraft under various conditions of speed, weight and missions configuration. Critical undercarriage structures and control surfaces may be monitored for fatigue damage induced by high-G maneuvers and high stress landings. These sensors are self-temperatures compensating, environmental resistant, have a high output, two active arms and are easily installed.
-
Product
Single Channel Detectors
-
Infrared detectors for gas analysis, flame detection and radiometry in TO18 or TO39 packages.Housing types TO18 and TO39Voltage or current modeSignal processing with JFET or operational amplifierThermally compensated (optional)With special chip holder for reducing the microphonic sensitivity (optional)
-
Product
BNC-2120, 68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777960-01
-
68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.
-
Product
16-Channel VME Analog/Thermocouple Input Module
V450
-
The V450 is a 16-channel 24-bit VME isolated analog-to-digital converter module which can acquire a wide range of DC voltages, including thermocouple readings with automatic cold junction compensation. Each channel is independently isolated with it's own A/D converter, signal conditioning, input protection circuits, and test relay.
-
Product
Cable Length Meter
CLM100
-
UEi Test & Measurement Instruments
The CLM100 Digital Cable Length Meter is an excellent tool to measure spooled cable/ wire. This best seller is built solid and supplied with a ruggedized boot for reliable field performance. Currently being utilized by major utility companies, electrical contractors, wholesalers, and installers where quick and accurate inventory management or measurements are needed for job accountability. Simply attach the Kelvin Clips to both ends of the cable and adjust the indicator to the size wire being measured. A temperature compensation circuit ensures accuracy by compensating for the temperature of the wire.
-
Product
PXI Temperature Input Module
-
PXI Temperature Input Modules offer up to 32 channels of analog temperature measurements. Some models include autozero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples, while others support 2-, 3-, or 4-wire resistance temperature detector (RTD) measurements. PXI Temperature Input Modules support both high-speed and high-resolution modes. You can program channel configurations and scale measured data into engineering units.
-
Product
Linearizers
-
Gain Shape Linearizer Amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run, or perhaps changing the input gain response to a MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
Product
sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
781210-01
-
Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
DIN-Rail Wiring Terminal Board With CJC Circuit
PCLD-8710
-
Low-cost screw-terminal with 68-pin SCSI-II connectorOnboard CJC (Cold Junction Compensation) circuits for direct thermocouple measurementReserved space for signal-conditioning circuits such as low-pass filter, voltage attenuator and current shuntIndustrial-grade screw-clamp terminal blocks for heavy-duty and reliable connectionsDIN-rail mounting case for easy mountingSupports PCI-1710U/UL, PCI-1710HGU, PCI-1711U/UL, PCI-1716/L
-
Product
GNSS Smart Antenna
iCON gps 70 series
-
For construction professionals, Leica Geosystems introduces the most efficient GNSS rovers, the Leica iCON gps 70 Series. With the iCON gps 70 T you can measure and stakeout points quicker than ever before without the need to keep the pole vertical and level the bubble. The combination of the latest GNSS technology and inertial measurement unit (IMU) equips the iCON gps 70 T with permanent tilt compensation and makes it resistant to any magnetic interference. Being fully calibration-free, the iCON gps 70 T is ready when you are – anytime, anywhere.
-
Product
8 Channels, RTD Measurement
RT1
-
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
Product
True RMS RF Millivoltmeter
3440A
-
The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.
-
Product
Uniload Voltage Transformer Test Set
2J6
-
The Type 2J6 Knopp Uniload Voltage Transformer Test Set consists of three major parts: When the Knopp Precision Transformer in the 2J6 set is compensated for, and used with, a secondary burden of 15 volt-amperes, for example, the ratio of this precision transformer is well within 0.02% and the phase angle is well within 2 minutes. The transformer, in common with other Knopp Precision Multirange Transformers, is wound so that it has practically the same ratio and phase angle accuracy on all ranges.





























