Compensators
-
Product
Saybolt Color Analyzer
-
optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.
-
Product
Dual Temperature
-
The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters.
-
Product
PRO High Range Conductivity Meter
MW302
-
MW302 is a Portable Conductivity High Range (EC) Meter with Automatic Temperature Compensation. This instrument has been designed to meet the Grower's need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. It is also a great meter for food, labs, and water treatment applications.
-
Product
Thermocouple Bench Selector Switches 6 or 12 Way IEC, ANSI
-
A 6 or 12 way selector in a moulded housing with aluminium front and rear panels. The rear inputs are switched via a front mounted rotary selector switch to the single output socket. Internally wired with thermocouple compensating cable and available with IEC or ANSI thermocouple types K, J, T, N & R/S.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF800
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations
-
Product
RH Temp External Probe
-
An external Relative Humidity and Temperature Probe for tight or remote locations. Every RH reading is temperature compensated for accurate readings. For environmental susceptibility, see Data Logger specification. Maximum extension is 30m (100').
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
2-MGEM Optical Anisotropy Factor Measurement System
-
The 2-MGEM Optical Anisotropy Factor Measurement System is a normal-incidence polarization reflection microscope designed to measure the sample Mueller matrix and is a 2008 R&D 100 Award Winner. This system is designed specifically to evaluate the Optical Anisotropy Factor (OPTAF) of cross sections of TRISO nuclear fuel pyrocarbon layers. Other possible material characterizations include measuring Mueller matrix elements of other crystals, carbon compounds, and thin film coatings (e.g. surfacedeposition films) at normal incidence. The 2-MGEM can also measure retardation (d), circular diattenuation (CD) and the polarization factor (ß). These parameters are not measurable using older techniques, since those techniques do not incorporate a compensating optical element.
-
Product
Flue Gas Analyzer (Instrument Only)
C160
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C160 Residential Combustion Analyzer is instrument only, easy to use with a rugged design, multiple sensor protections and altitude compensation. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Stand-Alone Doppler Current Sensor
DCPS
-
The Doppler Current Profiler Sensor (DCPS) is a medium-range, 600kHz current profiler smart sensor. It offers high-quality ocean current measurements and is ideally suited for cabling directly to various systems or dataloggers via serial or AiCap bus. With its integrated compensation for tilting and movement, the sensor is commonly used to measure current from buoys and other moving platforms.The 5400/5400R version of the current sensor is 300m depth rated, the 5402/5402R version is 4500m depth rated, and the 5403/5403R version is 6000m depth rated and intended for commercial as well as research use. It comes with an integrated temperature sensor that can be calibrated on request.As an extension to the DCPS, we now offer the current profiler with an integrated pressure unit called the 5400P. This version enables acoustic wave measurements in addition to profiling currents. Ideal for small observatories, the DCPS sensor is the market's lowest-cost current and wave sensor.
-
Product
C Series Temperature Input Module
Module
The C Series Temperature Input Module features up to 16 channels of temperature input from either thermocouples or RTDS. This module can include anti-aliasing filters, open-thermocouple detection, and cold-junction compensation. Additionally, the module also feature isolation for safety, noise immunity, and high common-mode voltage range.The C Series Temperature Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
Gain Shape Linearizer Amplifiers
-
Gain Shape amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run or perhaps changing the input gain response to a MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
Beer Refractometer
PA202X-799-803
-
Dual scale Digital Beer Refractometer for measuring Brix or Specific Gravity (D 60/60) of wort. These beer scales are temperature compensated specifically for wort.
-
Product
True RMS RF Millivoltmeter
3440A
-
The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.
-
Product
VOA DWDM with EDFA With VOA, EDFA Dense Wavelength Division Multiplexer
DWDA-1000 (100GHz)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai DWDA-1000 series is integrated by DWDM, VOA and EDFA module in a 1RU or 3D rack. Each channel of DWDM with a high-resolution factor electronic control adjustable optical attenuator will adjust and equilibrium the power. The insertion loss, power loss because of the channel equilibrium of DWDM will be amplified and compensation by the build-in gain flatness EDFA. Compact and simple device structure, thereby reducing the connections between devices to improve the index and reliability of the system. Can be used in DWDM system power equilibrium, optical add and drop multiplexed (OADW) flexible and expediently.