Loop Indicators
See Also: Indicators, Angle Position Indicators, Fault Indicators, Voltage Indicators
-
Product
Loop Powered Indicators
-
DEVAR loop powered indicators are designed to easily convert any standard 4 to 20mA loop signal to readout directly in engineering units. Optional back-lit display available.
-
Product
Angle Position Indicators
Angle Position Indicator
NAI offers a wide variety of Angle Position Indicators (APIs) that perform high quality analog-to-digital conversions of Synchro or Resolver data. These measurement instruments deliver industry-leading performance in a variety of accuracy and resolution grades, with various packaging options available. Multiple communication control interfaces include:*Touch screen*Front panel*Optical mouse*IEEE-488*Ethernet*USB
-
Product
Angle Position Indicator, High Accuracy
8810A
Angle Position Indicator
NAI's 8810A Angle Position Indicator (API) is a rack-mount or bench-top measurement instrument featuring front panel controls and input terminals. The use of an intelligent DSP design eliminates push buttons and allows all programming to be done either via an integrated touch-screen, front panel USB optical mouse interface, or with the multipurpose increment/setup knob. Improved flexibility is provided by two fully independent inputs that can be used to read two separate input signals simultaneously, or can be combined to measure multi-speed Synchros or Resolvers.Read more: http://www.naii.com/Angle-Position-Indicator-High-Accuracy/P196#ixzz3ztgONPA5
-
Product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
-
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
Product
Voltage Indicators
-
*Measures voltage from 100V to 138kV line‑to‑line.*Can be used individually as voltage indicators or together for phasing operations up to 100 ft (30 m) apart.*Two LED displays are automatically synchronized during phasing operations.*Clear in-phase and out-of-phase indication.*Versatile for overhead and underground applications.*Capacitive Test Point and Peak Hold modes
-
Product
Voltage/Current Indicator
CS3-VA
-
CS3-VA Voltage/Current Indicator has been designed in miniature size(24 x 48mm), and provide high accuracy measurement, display and communication of 0~300V or 0~20mA for DC/AC(average).They are also to build 2 Relay outputs, 1 External Control Input, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication.
-
Product
Single Loop Controller
1462
-
The N4400 is a sophisticated, single loop controller which provides extensive profiling programming options for complex processes. The controller can create a profile with up to 121 segments, store up to 8 programs and configure and store extra programs on a PC.
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
Digital Indicators
-
The precise measuring of dimensions is important for so many enterprises: engineering, surveying, construction, machine tooling and auto manufacturing, just to name a few. And electronic digital indicators provide people in these fields with the means to accurately measure the dimensions of objects both very small and very large by translating small linear distances into rotational movement. Precision measuring tools like electronic digital indicators can also be used to measure distance and range. If your job requires mechanical testing or machining, you may want to shop our selection of dial indicators.
-
Product
Monitoring Loops
-
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
Product
Phase Sequence Indicator
8PK-ST850
-
Two functions in one unit incluidng open phase and phase sequence. Large size alligator clips : able to clip on switch-board terminals easily. Identify 3 phase sequence and open phase check Ideal for installing conveyor lines, pump systems and interconnected drivers. No exposed metal parts. Safety features are incorporated throughout, including the pushbutton switch designed to minimize damage due to negligence. Safety approval: CE marks, IEN 1010 CAT. II.
-
Product
Line Indicators
LineTroll
-
Fault Passage Indicators to locate short circuit and earth faults.
-
Product
Indicators - Electronic
-
An electronic device used to read an input value from a measuring device and show a displayed value.
-
Product
Single Loop Controller
3200
-
The instrument has the largest red or green digital display in a 1/32 DIN package. In addition to the red or green display the 3200 benefits from three additional multi-colour LEDs to indicate process, alarm and configuration statuses.
-
Product
Voltage Indicators
-
Available with a digital readout or a simplified LED display Seaward's specialist range of voltage testers have the versatility and durability to cope with all types of user demands.
-
Product
MULTI-STANDARD LOCAL LOOP SIMULATOR
458-LM-A8-30
-
Accurately simulates attenuation and impedanceFull bidirectional operation at all specified frequencies26 AWG PIC as specified in ANSI T1.417
-
Product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
-
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
Product
Indicators - Test
-
Measures the deflection of the arm, the probe does not retract but swings in an arc around its hinge point.
-
Product
Single Loop Controller
1800+
-
The 1800+ controller is an evolved product from the West N8100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
Product
Indicating Instruments
-
In continuous level measurement, the filling height in a vessel is repeatedly detected. The measured value is further processed, e.g. as a 4 … 20 mA signal in a PLC or process control system. Indication of the measured value directly on site is also frequently requested.
-
Product
Loop Testing
-
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
Product
Indicators & Displays
-
30,000 displayed divisionsOIML R76 ApprovedStainless steel IP65 housingMains powered with 12V DC option25mm wide angle LCD display with back light2 programmable function keys and navigation keys provide easy operationLinearity correctionGravity AdjustmentLi-Ion long life rechargeable batteryAuto Power offPanel mount, desk stand, pole/wall bracket mounting includedRS-232C data port standard, 2nd RS-232C port optionTicket printing with Date, Time, Ticket no, Gross, Tare & Net Weight100 product memories for check weighing and countingSmart dynamic weighing algorithm for animal weighingCE approved
-
Product
Process Indicator
CS2-PR
-
CS2-PR Process Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~10V and 4(0) ~20mA with square root function.They are also build in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.
-
Product
Indicators
-
Watlow Electric Manufacturing Company
Watlow''s temperature and process indicators are ideal for displaying measurements of temperature and other process variables; such as flow, pressure and relative humidity. They are moisture resistant and include bright, four-character LED displays, user-selectable temperature units, sensor break protection, agency approvals including UL®, CE, RoHS compliance and multiple mounting options such as DIN-rail or panel mount configurations.
-
Product
Flow Indicator
Qualitrol 092
-
Designed to indicate “pump on” and “pump off” conditions within a forced cooling system. Select models also indicate flow direction. Up to two SPST or SPDT switches are available for control and/or alarm functions. Large dial face provides easy viewing and is magnetically coupled to the flange assembly allowing leak free replacement if damaged.
-
Product
Micro-Ohmmeter and Loop Resistance Tester
LRT 6000
-
LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.
-
Product
Opto-Isolated Current Loop Signal
4029
-
SPECTEC Innovative Sensor Solutions
SPECTEC's Model 4029 digital opto-isolated current loop signal conditioner prevents ground loops and interrupts any galvanic signals riding on magnetic speed sensor's output signal.. This signal conditioner converts magnetic, variable reluctance and inductive sensors' sinusoidal signals into a 4-20 mA output suitable for interfacing with process control units, dataloggers, flow controllers, and computers.
-
Product
Single Loop Controller
1460
-
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load