Loop Indicators
See Also: Indicators, Angle Position Indicators, Fault Indicators, Voltage Indicators
-
Product
Digital Weighing Indicator | Process Meter | Panel Meter
-
Mantracourt’s digital weighing indicator and panel meter modules are compatible with a wide range of sensors and transducers, including volts, amps, temperature, frequency, speed, load, force, pressure, torque, LVDT, RVDT and many more. The digital architecture offers simple one-pass calibration and fast setup.
-
Product
Loop Powered Trip Amplifier With Dual Relay Output
SEM1636
-
The SEM1636 monitors a (4 to 20) mA loop and provides two independent change over trip contacts set to trip at any point within the (4 to 20) mA range.
-
Product
Phase Sequence Indicators (Contact Type)
865 PR
-
Standard Electric Works Co., Ltd
● The 865 PR is a detector with LEDs to show the de- tection better visible than neon. ● Three functions in one unit, including open phase, phase sequence and 3 phase motor rotation.● Designed for checking a wider range of 3 phase power source from 100V to 600V.● Indicates R.S.T LEDs which frequency range from 40Hz to 400Hz.● Wide range detection of motor frequency range from 2Hz to 400Hz.● Fixed magnets for convenient measurement.
-
Product
Remote Indicators
-
ABB field indicators provide a convenient way to access the field instruments data when they are located in remote or difficult to access areas. Powered directly from the 4-20 mA current loop, they require minimal effort to setup.
-
Product
Gross Alignment Funnel / Enhanced Latch Indicator (GAF/ELI)
-
A wet-mate connector system designed to optimize ROV mating efficiency, the Gross Alignment Funnel (GAF) can be used in conjunction with the Enhanced Latching Indicator (ELI) to overcome severe approach angles of ROV connectors during mating. In conditions with low visibility and heavy current, the system aids in aligning the mating halves and providing a clear visual indicator when a successful mate occurs. Easily installed on an existing Nautilus or Rolling Seal bulkhead mounted connector, the system reduces ROV operator variability, resulting in faster mating and demating operations.
-
Product
Digital Indicator for Strain Gauge Sensors
AD-4530
-
Low cost digital indicator for various applications. Suitable for measurement of load, pressure, torque, tension and more at an affordable price.Digital Zero (DZ) stores zero data at any measurement point. This function can also be used to tare weight. Measurement can simply be restarted when it was interrupted by a loss of power.Power on zero function adjusts to zero when the power is turned on.Digital filter provides stable measurement results.Digital span calibration. Easy calibration just by inputting the rated output of a sensor. No need to use a mass.
-
Product
Sound Level Indicators
-
A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.
-
Product
Loop Tack Tester
-
Loop Tack Tester is applicable to measure the tack property of adhesive tapes, pressure-sensitive adhesives (PSA), and adhesive materials according to ASTM D6195.
-
Product
Current Loop Supply Isolating Transmitter
Model TWS / TWS 2
-
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
Product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
-
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
Product
Portable Hand Held Load Cell Indicator
MODEL SSI
-
The SSI is a Plug & Play Smart TEDS IEEE 1451.4 compliant portable handheld Load Cell Indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SSI can be set up by simple front panel push buttons. The SSI can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a Units key for automatic conversion of readings for load, torque and pressure. The SSI has an ultra-fast signal-sampling rate of 15,360 samples/second for true peak and/or valley testing capability. Auto-tare allows the meter to be set to zero for any input signal level. The SSI also features a USB port for data logging to a PC. You can also log data to the SSI’s internal memory storing up to 16,000 time and date stamped readings. The SSI also features 2 built-in solid-state alarm relays with LED and audible indicators. The SSI will operate up to 65 hours on a single charge or use the included battery charger for applications where the SSI is mounted permanently.
-
Product
Saicheng Adhesive Loop Tack Tester
-
VOC-01 Loop Tack Tester is applicable to measure the tack property of adhesive tapes, pressure-sensitive adhesives (PSA), and adhesive materials according to ASTM D6195.
-
Product
Lipo Battery Power Level Tester & Alarm to Indicate Low Power
#52023
-
Can be used for 7.4V (2S pack)and 11.1V (3S pack).Red LED will flash when cell is below 3.3V and an Alarm will sound when cell is below 3.0V indicating the Lipo Battery pack should be recharged.
-
Product
Load Cell Indicators
-
Procter & Chester Measurements Ltd
The instrumentation will power the load cell. The mV/V signal coming back from the load cell is converted by the indicator and displays the force in a unit (e.g.: Kg, kN, lb – customers choice). The indicator will need to be mounted in to a case or control rack for safe use.
-
Product
Intelligent Transmitter with Digital Indication
LEO 3
-
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions:
-
Product
Loop Antennas
-
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
Product
Equipment Condition Indication
MetalSCAN
-
Condition indication in real-time, so you can schedule maintenance at the right time.MetalSCAN is the leading real-time, on-line condition indication technology designed to alert equipment operators to bearing and gear damage, long before equipment failure. Nothing else comes close. Its advanced capabilities deliver knowledge that transforms equipment failure to predictable and avoidable high cost events. Use MetalSCAN to optimize maintenance schedules, reduce repair costs, increase reliability and improve safety.
-
Product
Line Mounted Fault Indicator
LineTroll 110Eμ
-
Linetroll 110E contains magnetic and electric field sensors surveying line current and line voltage. The magnetic sensor automatically adapts to line current, detecting preset current increases. The electric field sensor is monitoring the presence of line voltage. The sensor signals are processed and compared with user set alarm criterias.
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
Pitot Static Indicator
ADSE 740
-
The ADSE 740 is a complete high performance dual pressure Ps and Pt standalone test bench specially designed to be used in the workshop or in the laboratory to test and calibrate all air data equipment such as altimeters, vertical speed indicators, air speed indicators, MACH-meter, air data computers ...) and sensors.
-
Product
Active Loop Antennas / Magnetic Field Probes
-
Is an active, shielded handheld loop antenna with nearly con- stant antenna factor over the entire frequency range. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Phase Sequence Indicators (Contact Type)
855 PRA
-
Standard Electric Works Co., Ltd
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
-
Product
Digital Temperature Indicators
-
Premier's Temperature Indicators are commonly used for applications like monitoring of melting furnaces, determining completion of chemical analysis, monitoring of conveyors, checking completion of heating cycle, monitoring of moulds and dies, preheating temperature confirmation, determining temperature rise, preforming heat treatment, checking temperature in manufacturing process, transporting chemicals, laying pipelines with wall and sub sea temperature measurements.
-
Product
One Core Loop Tester
-
DAMUL is an innovative and portable optical power checker accompanying 1-core loop back function. DAMUL can check SFP TX and RX power level by simply inserting SFP into it. If you use UPM (Universal SFP-typed Power checker Module) optionally provided, DAMUL can measure optical power. Also, when using SPM (SFP-typed Power checker Module) optionally provided, DAMUL can identify 18 CWDM wavelengths as well as its power automatically. DAMUL provide users high productivity for optical power checking work on fiber optic systems such as WDM-PON.
-
Product
Voltage/Current Indicator
CS3S-VA
-
● Measuring: DCA, DVC, ACA, ACV● Accuracy: ±0.1%(DB), ±0.2%(AC)● Display range: -1999~9999● Dimension: 1/32 DIN (48x24mm)● High Stability and reliability
-
Product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
Analog Output Module
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
RS485 Remote Display Indicator
CS1-8
-
CS1-8 has been designed for remote display by RS485 (Modbus RTU Mode) interface.
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.





























