Standards
A controlled reference or acknowledged technical criterion.
See Also: IEC, IEEE, Mil, Interoperability Test, Compliance
-
Product
Nanoscale Microscopy Standards
-
The nanoscale AFM-CD standard (CD, critical dimension) contains structures to calibrate line widths and periods of AFM (atomic force microscopy) devices.
-
Product
Open Network Standards
ControlNet
-
ControlNet is one of three open network standards (DeviceNet, ControlNet and EtherNet/IP), all of which use a common application layer, the "Common Industrial Protocol" (CIP). The Family of CIP Networks is specified and published by ODVA (Open DeviceNet Vendor Association - http://www.odva.org) and CI (ControlNet International - http://www.controlnet.org).
-
Product
Helmholtz Coils (Field Standards)
-
Lake Shore offers four Helmholtz coils for field standards: 2.5 in, 6 in, and 12 in diameter single axis, and the MX-2X-10 double axis coil. Standard field coil (field generation). Field strengths from ˜12 G to ˜30 G. Field accuracy of 0.5%. Field uniformity of 0.5%*. Single axis configuration with 2.5 in, 6 in, and 12 in diameter coils.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Light Sources & Calibration Standards
-
Photometric Solutions International Pty Ltd
We offer a range of specialised and customised light sources for various applications.The spectral range goes from 200 nm to 40 µm.
-
Product
Custom Optical Components and Standards
-
With the amount of applications that optical components have, no one could hope to have the perfect component for every possible scenario. For this reason, APPLIED IMAGE makes easy the process of designing, building, and delivering custom components to our customers. Our engineering process is designed to produce the best parts in the industry and more importantly, the best component for your specific needs. The APPLIED IMAGE experience will cover the project with expert engineers from start to finish. Use the form below to start the conversation for checkerboard and dot arrays, stage and image analysis micrometers, reticles and machine vision components.
-
Product
Individual UPC Bar Code Standards
-
The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)
-
Product
Standards
7X
-
WENS series Frequency / Voltage / Wave / Carrier Standards is an ideal and smart solution for distributing signals from Quartz or GPS receivers. Designed to multiple output for multiple applications.
-
Product
ITO Sheet Resistance Standards (ITOSRS)
-
Indium Tin Oxide Sheet Resistance Standards (ITOSRS) from VLSI Standards are NIST-traceable products, intended for calibration of both contact and non-contact sheet resistance measurement tools used in the LCD, flat panel and touch-screen markets.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
UL Standards Testing and Certification
-
If you are selling your product in the United States, your product must comply with the applicable nationally accepted UL standards. F2 Labs can evaluate and test your product, help you through the UL certification process and enable you to certify your product to the UL requirements through a Nationally Recognized Test Lab (NRTL).
-
Product
Temperature Stabilized Resistance Standards
-
Measurements International Ltd.
The temperature stabilized resistance standards offer customers the very best in accuracy, and stability. With 3 different models to choose from, covering the full range of resistance values.
-
Product
Calibrated Diffuse Reflectance Standards
-
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
Product
FlexVNX+ 8-Slot Test And Development Platform Aligned To SOSA And VITA 90 Standards
39S08VPXZZY2VAND
-
Elma’s all-new FlexVNX+ Test and Development chassis is the next generation portable test platform designed to accelerate development and test of VNX+ plug-in cards (PICs) aligned to The Open Group® SOSA™ Technical Standard and VITA 90.
-
Product
2210A & 2211A Quartz Frequency Standards
-
Precise Time and Frequency, Inc.
The ptf 2210A Quartz Frequency Standard has been designed to provide a highly stable and spectrally pure frequency reference for applications requiring the ultimate in short term frequency performance.The instrument contains a double oven controlled stress compensated (SC cut) quartz crystal oscillator (OCXO) to give the ultimate in performance.Ideal for laboratory or system use, the unit provides good stability performance at lower cost and with improved phase noise.
-
Product
Frequency Standards
-
Precision Test manufacturers a complete range of frequency standards. This includes rubidium and OXCO models either free running or controlled by an external reference (GPS, GLONASS, Galileo, 1pps, 5 MHz, 10 MHz, IRIG-B etc). Output frequencies typically 1 MHz, 5 MHz, 10 MHz, 10.23 MHz, 13 MHz, 100 MHz or bespoke frequency.
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HC-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard Connectors
-
C.C.P. Contact Probes Co., LTD.
The Standard Connector Series aims to offer a comprehensive selection of internationallycompatible connectors. Its smart design and simple structure makes it very cost effectiveeven at small volumes.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard 1.63 (46.00) - 4.50 (128.00) Battery Probe
CP-059-19
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
Product
Standard 0.81 (23.00) - 4.50 (128.00) Battery Probe
CP-059-026
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.00Mechanical Life (no of cyles): 100,000Overall Length (mil): 221Overall Length (mm): 5.61
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Connector
-
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Analytical Reference Materials & Standards
-
Agilent, now with former Ultra Scientific, offers a comprehensive portfolio of analytical standards, reference materials and certified reference materials for environmental, food safety, elemental analysis, instrument calibration, tuning mixes, and more.Reference materials and certified reference materials are substances that are tested to be homogenous and have fixed values of its concentrations. These standards are a critical component of your application workflow - from sample prep, instruments, columns, supplies, and services. The success of your analysis depends upon the quality of your reference material. All Agilent standard reference materials have been manufactured to the highest quality in an ISO 9001, ISO 17025 and 17034 accredited facilities to ensure the accuracy of your analyses.If you need a custom reference material, partner with us to design and develop a custom standard to your specifications.
-
Product
PCMCIA Card
DAS-429PCMCIA/RT10
-
Both cards contain 68 Kbytes of true dual-port RAM, for data blocks, control registers and Look-up table, mapped within the Common Memory space. The card also contains a FLASH-based Card Information Structure (CIS) within the Attribute Memory space.The cards comply with the Personal Computer Memory Card International Association (PCMCIA Release 2.1) standard, including Plug and Play. The card's small size and suitability for PCMCIA compatible notebook computers with Type II and Type III slots make it a complete solution for developing and testing ARINC-429 interfaces and for performing system simulation of the ARINC-429 bus, both in the lab and in the field.The cards are supplied with C drivers, including source code, Mystic Windows software and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application.
-
Product
Interrogation Monitors
-
Ibsen Photonics’ I-MON Interrogation Monitors set new standards for fast, real-time spectrum monitoring of FBG sensor systems.
-
Product
Directional Source
BAS003
-
The BAS003 Source is designed to generate homogeneous sound fields using random noise in compliance with the following standards: Building acoustics (insertion loss, acoustic absorption area, etc: ISO 140-3, ASTM E90, ISO 140-5, ASTM E966). The BAS003 is typically used to generate a noise in a free-field for the evaluation of the transmission loss index of a façade. The available high-efficiency power amplifier, BAS002, is light and can be remotely controlled for easy use in the field.