Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
Pull Out Device
BCL-1
-
This Pull out device BCL-1 is designed and manufactured according to relevant standard requirements of IEC884-1/ GB2099.1-2008 and other electrical accessories standards, Mainly used to test the needed maximum force when the plug pull out from socket and the minimum force when single stage plug pull out from socket, and to inspect whether the socket can withstand the lateral stress imposed by electric plug into the socket. This device is applied to plugs and sockets which rated voltage no more than 250V and rated current no more than 16A.Specifications: • Weights: 36N*1, 5.4N*1, 5N*2, 4N*1, 2.6N*1; • Standard testing plug: each one for Dipolar 10A, tripolar 10A and 16A • Standard test bolt: Each one for 1.5N and 2N • 1 set of clamping device • 1 set of Weights tray • Lateral stress weights 5N*1 • 1 set of lateral stress bar
-
Product
Luminance Colorimeter
XYL-VI
-
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.
-
Product
LED Driver Online Tester
LEDLS-60/LEDLS-12
-
• The tester includes A Group Measuring Module and B Group Measuring Module. The A Group measuring module can test 6pcs LED Driver AC Parameters. The B Group measuring module can test 6pcs LED Driver AC, DC and AC/DC Parameters. • There are 12 windows to display the input and output parameters, it is good for comparing and analyses. • Quick test for all of the parameters in 0.1 seconds. • It can set up the testing parameters PASS/FAIL range, it will have Noise/Light warning if it is Fail. We also supply handle port (Extra cost) • Software communicate with PC (Extra cost)
-
Product
Magnetic Material Analyzer
UI9730
-
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, μm, magnetic core loss, B-H curve, U curve and I curve• Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz
-
Product
Mask Bacterial Filtration Efficiency (BFE) Tester
WKS-1010
-
WKS-1010 Mask Bacterial Filtration Efficiency (BFE) Tester is used to test the percentage of the mask material to filter out the suspended particles containing bacteria under the specified flow rate. It is suitable for the performance test of the bacterial filtration efficiency of medical surgical masks by metrological inspection departments, scientific research institutes, medical mask manufacturers and other related departments.
-
Product
GNG-* “Go” and “Not go”gauge
GNG-*
-
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
Product
Automatic Double Drop Test Machine
DT-JT
-
The machine wills automatic stop positioning after sample reach up to the sated height position. According to the different size to choice the test distance between tests arms, electric pulse width. The release mechanism of machine are flexible and reliable, to ensure the sample without any external influence during the release of instant and free fall way, and make sure it meet sample’s dropping requirements. It is according to GB4757.5-84), GB/T4857.5-92, GB/T2423.5, IEC68-2-27, JISZ0202-87, ISO2248-19, ISO2248-1985(E, ASTMD5276-1998 and ISTA3A. This series drop test bench for measuring the main simulation packages in the transportation, loading and unloading process under drop impact influence, identification package impact strength and packaging design.
-
Product
Auxiliary Lamp
RLS-50W
-
Due to the luminaries self-absorption, the auxiliary lamp is used to correct the flux test value. Work with the follow instruments as a System
-
Product
Optical Radiation Safety Test
EN62471-C
-
IEC62471-2006(CIE S009) Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
Product
Wire Damaged Tester
WDT-1
-
This equipment is designed and manufactured according to corresponding regulation in standard IEC884-1, GB299.1-96, GB16915.1-97 and other electronic accessories relevant standard. Mainly used to test damage degree of fixed connection components lead wire of with thread clamping type and no screw terminals, so as to inspect whether it can withstand mechanical stress during normal use.Specification: • Power supply: AC220V 50Hz • Test rate: 10±2r/min (GB16915.1-97: 12 ±1r/min) • Rotating radius: 100mm • Test distance: 250~500mm adjustable • Test numbers (Number of rotating): 0~999999 any set • Mass: 0.3KG, 0.4KG, 0.7KG, 0.9KG, 1.4KG, and 2.0KG (GB16915.1-97: 30N, 40N, 50N, 60N each of 2 pcs) • Stations: 2 • Dimension: 1200×1400×400 (mm) • Remarks: The mass and rotating radius can be optional as per customer requirements.
-
Product
Digital Power Meter (High Accuracy Model)
LS2050
-
LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.
-
Product
PWM Type AC Power Supply
LSP-5KVA
-
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Product
CCFL Ballast Tester
WT2000A-CCFL
-
This tester is specially designed for analyzing the electrical characteristics of CCFL Electronic Ballast, meets the test requirements in international standard• Input characteristics analysis: measure Vrms, Irms, W, PF, Hz, phase angle Measure THD, 0 to 39th harmonic components, Accuracy: ±(0.4% reading+0.1% range+1 digit)• Output characteristics analysis: measure lamp voltage, lamp current, lamp power, oscillatory frequency, crest factor of lamp current, Accuracy: Class 2• Interface RS-232C provided for easier communication with PC for printing test report
-
Product
Pocket Brightness Meter
PHOTO-100L
-
• Measuring range: 20cd/m2~2000kcd/m2; • Testing accuracy: Class 1; • Display refresh rate: 1times/sec; • Power source: 9V battery; • Power consumption: less than 20mW; • Normal technical specifications: 1) Temperature: 0~40℃, 2) relative humidity: less than 90%
-
Product
LED Optical Aging Test Instrument
LEDLM-80PL
-
LEDLM-80PL LED Lumen Maintenance and Aging Life Test System is designed according to standards of IES-LM-80, IES-LM-82, TM-21 and GB2312-80, and the software is developed base on Arrhenius model. LED has the features of long life, but with the different working condition and drive current, its life will be different, but generally the life will be around 50K hours. Differ from the traditional lightsource, LED light will decay gradually rather than extinguish instantly, so in the standard of LM-80, it introduces L70, L50 and etc.