Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
Electronic Ballast Production Line Tester
UI2000-OK
-
• Eight windows for displaying input characteristics, output characteristics, convenient for comparison and analysis. • Frequency response for testing input current up to 1 MHz, suitable for precise testing of various kind of electronic ballast. • High speed testing, finish testing input and output characteristics within 1 minute. • Portable with built-in chip micro-processor, particular suitable for development and spot production. • Parameters, waves and curves of input, output and startup can be printed. • Communicating with PC, special software provided and both Chinese version and English version available. Run in WINDOWS3.2, WINDOW95 or WINDOWS98, nice interface between people and computer, easy to operate.
-
Product
Wire Damaged Tester
WDT-1
-
This equipment is designed and manufactured according to corresponding regulation in standard IEC884-1, GB299.1-96, GB16915.1-97 and other electronic accessories relevant standard. Mainly used to test damage degree of fixed connection components lead wire of with thread clamping type and no screw terminals, so as to inspect whether it can withstand mechanical stress during normal use.Specification: • Power supply: AC220V 50Hz • Test rate: 10±2r/min (GB16915.1-97: 12 ±1r/min) • Rotating radius: 100mm • Test distance: 250~500mm adjustable • Test numbers (Number of rotating): 0~999999 any set • Mass: 0.3KG, 0.4KG, 0.7KG, 0.9KG, 1.4KG, and 2.0KG (GB16915.1-97: 30N, 40N, 50N, 60N each of 2 pcs) • Stations: 2 • Dimension: 1200×1400×400 (mm) • Remarks: The mass and rotating radius can be optional as per customer requirements.
-
Product
Digital Colorimeter & Illuminance Meter
CHC-I
-
This Digital Color Meter & Illuminance Meter is based on all digital integral photometric and colorimetric measurement technology. It has no analogue unit, thus it is very simple to overcome the zero drift which is impossible to be avoided in current colorimeter. The digital X (λ), Y (λ), Z (λ) sensor has large dynamic range so that there is no range-changing error in it; moreover, it possesses strong anti-interference ability and high accuracy. The CHC-I contains internal RS232 computer interface, the calibration is done by software. It is suitable for monitoring and remote applications. The CHC-I software can calibrate the instrumentation, sample the data through RS232 interface and print out the results. It can also be calibrated by other standard light sources to obtain very high measuring accuracy of x, y color coordinate and color temperature. It is a real-time measuring system and run under Windows System. 128*64 lattice LCD display, RS232 computer interface and software, Data hold function.
-
Product
EMI Test System
EMI-9KA
-
EMI-9KA is an automatic EMI receiver. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KA is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KA fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
-
Product
Composite Salt Spray Test Chamber
YWX/Q-010X
-
Composite Salt Spray Test Chamber stimulate the actual natural conditions to do accelerated corrosion test, all the testing are based on common states on the natural environmental: such as combine with salt spray, hot air drying, humidity, low temperature and so on. The test samples are widely used on the intense changes in the environment, like automobile parts, aviation equipment, building materials, coating, electric and electrical machinery so on. YWX/Q-150X series is full compliance with ASTM D4728I, EC 60068-2-1, IEC 60068-2-14 and EIA/JEDEC JESD22-110-B standard requirements etc.
-
Product
Three Loop Antenna
VVLA-30M
-
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
Product
Auxiliary Lamp
RLS-50W
-
Due to the luminaries self-absorption, the auxiliary lamp is used to correct the flux test value. Work with the follow instruments as a System
-
Product
Electronic Components Test
-
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, m, magnetic core loss, B-H curve, U curve and I curve Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz Accuracy: 2% With 12-bit high-speed A/D, sampling rate up to 40MHz, ensuring data precise and stable test result Supermaximal database, suitable for almost all kinds of magnetic material in market, such as: circle, E ,U , ETD-EER, JAR, RM , EP , PM , EL , ER, PQ, EFD, plane E, etc Perfect software interface enables observation of curve in detail Meet international test requirements for magnetic particle ASTM E1444, ASTM E709-08.
-
Product
Thermally Protected Ballast Heating Test Chamber
TPB-UL935
-
Working room dimension: 610×610×610mm• Temperature range: RT+10℃~+100℃• Materials of inner and outside chamber: Senior stainless steel• Insulation Material: Ultra-fine glass wool insulation material• Heater: Dedicated strip heater (heating surface area of 300 × 40 mm), each group three hundred watts, a total of four groups, with the power supply in parallel.• Special wooden test sample holder• Third gear temperature measurement points (at any time monitoring and conversion)
-
Product
AC Power Source
LSP-500VAR
-
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
Product
Electrical Safety Tester
-
Basic testing methods of Glow wire device> and UL 746A, IEC829, DIN695, VDE0471, the Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. Adopting high-temperature coating spraying on steel structure and imported instrument display, with easy operation, stable performance the equipment is applicable to flame resistance tests of all levels of QC departments and corresponding enterprises.
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
Insulation Resistance Tester
WB2681A
-
• Insulation test voltages: DC250V、DC500V、DC1000V • Range of open-circuit voltage: ±10% rated voltage • Testing time: 3~99 seconds or controlled manually
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
Impulse Test Generator
SUG-CCITT-A
-
Impulse Test Generator SUG-CCITT-A (1a. 10/700us, 6KV, figure is according to N.1 in IEC60950-1:2005 Annex N). N.1 ITU-T impulse test generators.















