Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
EFT Immunity Measurement
EFT61000-4
-
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance, such as high stability, high reliability, easy to use etc. It meets the standard requirements of IEC 61000-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in both English and Chinese.
-
Product
Programmable Withstanding Voltage & Insulation Test
LS9923
-
LS9923 programmable withstanding voltage & insulation test system is high-performance testing device special for AC&DC Withstanding Voltage and Insulation Resistance Test, It allows setting the output voltage. The warning value,testing time and some other parameters can be set in the screen.It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the develop research.
-
Product
Car Accessories Material Burning Tester
ZRS-4H
-
• Test Gas Source: Gas or Liquefied Petroleum Gas (Suggestion: Use good quality gas if possible) • Burner inner diameter: ¢9.5±0.5mm, about 100mm long with air adjusting hole • Height of flame: Can be adjusted from 20 mm to 100 mm according to the standard requirement • Applying time of flame: Burning time can be adjusted from 0 to 99 minutes 99 seconds • Test process: Automatic control • Inner volume: 0.05m³ • Material: Stainless steel or iron plate spray • Power: AC 220V; 50Hz/5A
-
Product
Integrating Sphere With Holder Base
IS-*MA
-
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
Product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
-
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
Product
Voltage Probe
VOL-PBE
-
• EMI Receiver equipped with voltage probe can test disturbance voltage from load terminals or control terminals
-
Product
RoHS Testing Equipment (EDXRF)
EDX-2
-
Rapid development of global economy brings serious environmental issues, which is becoming the focus of all around the world. The RoHS directive EU announced on Feb 13th of 2003 became effective on Jul 1st of 2007 for the purchase of restricting the pollution caused by the dispose of electronic and electrical products. Facing this environmental protection requirement, after years of hard work on R&D, Lisun has successfully developed EDX serious EDXRF spectrometer. EDXRF can detect and measure the hazardous substances restricted in RoHS directive quickly, precisely and nondestructively.
-
Product
Magnetic Material Analyzer
UI9730
-
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, μm, magnetic core loss, B-H curve, U curve and I curve• Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz
-
Product
Fluorescent Lamp Asymmetric Pulse Tester
UI2002C
-
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
Product
High and Low Temperature Thermal Shock Chamber
HLST-500D
-
The specimen is placed in test chamber specimen which cannot be placed in high temperature chamber or low temperature chamber. High temperature chamber pre-heats the air and low temperature air chamber pre-cools the air. When doing the test of temperature changing from high to low, the low temperature chamber will blow the pre-cooled air to the test chamber. Then, the air in test chamber will reach your target temperature in several minutes (“recover time”). When doing the test of temperature changing from low to high, the high temperature chamber will blow the pre-heated air to the test chamber. Then the air in test chamber will reach your target temperature within the recover time.
-
Product
Electronic Ballast Analyzer
WT3000
-
• It has 8 windows to display each parameter of input and output characteristics • Frequency response for testing input current up to 1MHz, suitable for precise testing of various kind of electronic ballast • WT3000 has expanding analysis for envelope wave. • Symmetry analysis for envelope wave’s crest factor of lamp current • Sampling at ultra-high speed, dynamic analysis single frequency curve, highest sampling frequency is up to 10MHz • Portable with built-in chip micro-processor, particular suitable for development and spot production • RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7
-
Product
High and Low Temperature & Low Pressure Chamber
LAP-100
-
It is according to GB10590 / GB15091 low temperature / low pressure test chamber requirements; GB11159 low pressure test chamber requirements; GB / T2423. 25-1992 low temperature / low pressure integrated chamber requirement; GB / T2423. 26-1992 High temperature / low pressure integrated chamber requirement; GJB150. 2-86 low temperature / low pressure test etc standards. It’s used to test the In aviation, aerospace, information, electronics and other fields, to determine the instrumentation, Electrical products, materials, components, equipment etc.
-
Product
GNG-* “Go” and “Not go”gauge
GNG-*
-
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
Product
Surge Generator
SG61000-5
-
Automatic lightning surge generator (or Lightning surge immunity) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
-
Product
EMI and EMC Test System
-
EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem.