Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
Optical Path Converter
LS512A/LS512B
-
There are many LED manufactories using two integrating spheres and one spectrophotometer to do test. The previous testing way is: when you use big sphere to test, the customer need to connect the detector cable and optical fiber from the Spectrophotometer to the big sphere, after the calibrating and then you can do the test. When you use the small sphere, you need to take away the detector cable and optical fiber from the big sphere to the small sphere, then need to calibrate again. It is too troublesome to take out the detector cable and optical fiber between the big sphere and small sphere, and you need to calibrate again for every change. The frequent change will also shorten the life of the detector cable and optical fiber.
-
Product
Absorbing Clamp
AB-CLP
-
• EMI Receiver equipped with absorbing clamp can indirectly test radiated interference power of household electrical appliance, power tool and similar electrical appliance with frequency from 30~300MHz.
-
Product
Pulse Start Generator for High Pressure Sodium Lamp
LPSG60662
-
The start-up test of the special lights pulse start generator is for lighting class industry such as high pressure sodium, it is according to IEC60662: 2011 and GB/T13259-2005 standard requirements.
-
Product
DC Power Source for Standard Lamp
DC502
-
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
Product
Reflection/Transmission Test Chamber
CHTR-100
-
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.
-
Product
HVR-LS Horizontal Vertical Flame Tester
HVR-LS/HVR-LSS
-
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC695-2-2 and GB Standard. It is used to test the appliances and plastic materials parts of electrical equipment for the horizontal, vertical flammability test. The product tank shell is irony spray, and configured a transparent viewing window, the digital meter shows the burning time, afterflame time, afterglow time, this device has beautiful appearance, is easy to use and has reliable performance.
-
Product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
-
Cabinet Shell 2mm galvanized cold-rolled steel sheetCabinet Door 0.9*1.7m(L*W) 0.6*0.6mCabinet Window 0.3*0.3*0.025m(L*W*T) with 4mm hole N/APower Supply Filter 30A/220V 30A/220VInternet Line Filter RJ-45 N/ACabinet Inside Decoration PVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size 2*1.2*1.8m 0.8*0.8*0.8mAfter Packing Size 2.2*2.3*2.3m 1*1.1*1.2mAfter Packing Weight 800kg 200kgWorking With EMI-9KA/EMI-9KB EMI-9KA/EMI-9KB, PC, Testing load, and operator inside Testing load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
Product
Pocket Chroma Meter
CHROMA-2
-
CHROMA-2 Pocket Chroma Meter is developed based on TOSHIBA TCD1304DG linear array CCD detector. It makes traditional laboratory instrument available for the production on-line quality acceptance, thus greatly improved the efficiency of fluorescent lamp, CFL, LED.
-
Product
2D Video Luminance Meter
LS-ELF
-
LS-ELF can record 15 frame’s 2D luminance data per second. Also LS-ELF can record the image while driving 60-80km/h speed. It can be used in many fields as Display, Light pollution, Lighting, Lab, etc.
-
Product
Digital Power Meter (AC & DC Model)
LS2012
-
• Measure Vrms, lrms, W, PF/Hz; • Measure AC, DC, AC+DC; • Automatic selecting, out of limit alarming, advance the work efficiency; • Voltage range: AC: 5-600V, DC: 1-600V. Current range: AC&DC: 0.005-20A with high measure accuracy. Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit).
-
Product
Integrated Function Tester for Inductance Ballast
UI2001B
-
• Measure input parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components. V range: 10.0~300.0V, A range: 0.010~2.000A, F range: 45~65Hz • Measure output parameters: Vrms, lrms, W, PF, Hz, current crest factor, total harmonic and 0~50th harmonic components Lamp voltage range: 10.0~450.0V, Lamp current range: 0.010~2.000A • Accuracy: ± (0.4% reading+0.1% range+1 digit) • Can test every kind of curve, print both data & curve • Communication interface available for PC, running under Windows98/2000/XP/Vista
-
Product
Constant Temperature Integrating Sphere
IS-*MT
-
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
Product
Fast Photo-Electric Tester
LS616S
-
The machine is made up of three main parts: measuring circuit of electric parameter, measuring circuit of photometric parameter and circuit of CPU system. Voltage and current signals are amplify and sent to high speed A/D transform, and the transform digital signals are sent to microprocessor, the input current signals of brightness detector are sent to A/D transform via I/V convert, and the transform digital signals are sent to microprocessor. Microprocessor processing the input photometric and electric data, it automatic switch between different range and calculate and display the data in the mean time.
-
Product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
-
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Digital Power Meter (Harmonic Analyzer Model)
LS2010
-
• Measure Vrms, lrms, W, PF, Hz; • Harmonic distortion analysis for voltage & current, display total harmonic and 0-50 times; • Component harmonic, selectable for absolutely or relatively harmonic display; • Voltage range: 10.0-600.0V, Current range: 0.010-20.00A, Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit); • Simultaneously display Vrms, lrms, W, PF value on 4 windows, suitable for production line; • Can test every kinds of curve; Print both data & curve; • Communication port for PC, run under WinXP or Win7.