Modbus
communications protocol for sharing data between controllers.
See Also: Communication Protocol, Near Field Communications, Data Communications, Modbus RTU
-
Product
M-2000 Modbus RTU Remote Data Acquisition Modules
-
M-2000 data acquisition remote I/O modules are similar to our I-2000 modules and support both Modbus RTU and DCON protocols. They come in a wide variety of analog and digital configurations. The analog and digital I/O types they support include: current, voltage, thermistor, thermocouple, frequency, relay, strain gauge, etc.
-
Product
Multi-Function Power Transducer
TD2418B
-
The TD2418B is a micro-process based transducer with a 16 bits CPU (Center process unit) and equipped with full-digitized measuring, calibrating and output functions.TD2418B not only can take the place of several static con-verters and measuring instruments (V, A, W, PF, VAR, WH, VARH, Hz) by single unit, but also have some special function such as Maximum measuring, Minimum measuring and comparator output. In communication, we use the most convenient and the easiest RS232 or RS485 as our standard output port, besides, we adopt Modbus Protocol, one of the most popular protocol in the world, as our standard protocol.
-
Product
Modbus Digital Input Output Modules
DAT3100 Series
-
The Datexel DAT3100 series is a range of Modbus digital input output modules. These cards or modules have the ability to accept digital voltage inputs and provide an output by the way of relays, NPN or PNP transistors. The DAT3100 devices can communicate with RS485 or RS232 on a Modbus or ASCII protocol making the DAT3100 series a very economical solution to large and small scale Data Acquisition. Combining these digital input output devices with the DAT9000 controllers and the DAT3000 analog input output modules make Datexel the smart choice where Data Acquisition is needed.
-
Product
Thermocouple Temperature Indicator
CM2-TC
-
CM2-TC Thermocouple Temperature Indicator has been designed in simple operation and 4 digital 20mm LED display with economic cost.They are can be programmed by buttons that are hidden in front panel.They are also available to option relay output and an analog output or RS485(Modbus RTU Mode) communication.
-
Product
8DI/8DO (Source Type) IoT Modbus/SNMP/MQTT Ethernet Remote I/O
ADAM-6052
-
8ch digital input(counter)/8ch source type digital output(pulse output)Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful API,ASCIIGCL to perform basic logic control rulesPeer-to-Peer function to map I/O statusCloud access: Data update to AzureBuilt-in web serverWatchdog timer to recover the system
-
Product
5 Digit Tacho/Linear Speed Meter (1/32 DIN)
CS3-RL
-
CS3-RL indicator was designed with high accuracy measurement of pulse and frequency.The innovation feature is input from 0.01Hz~100KHz the display resolution will auto-range according input frequency to shift decimal point.A compact body design for small equipment, laboratory instrument, and others.Also are available option relay output, analog output, RS485 Modbus RTU communication for most popular applications.
-
Product
10 Digit Rate/Batch Counter (Analogue)
CS2-TM-Analogue
-
The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.
-
Product
16FE+2G Combo Managed Ethernet Switch Support Modbus/TCP, -40~75℃
EKI-5626CI-MB
-
16 Fast Ethernet ports + 2 Gigabit Copper/SFP combo ports (EKI-5626C/CI-MB)Entry-Level Managed SwitchIXM function enables fast deploymentManagement: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB
-
Product
4 2/3 Digital Potentiometer Meter
CS2-PM
-
CS2-PM Potentiometer Indicator has been designed with high accuracy measurement, display and communication of Ohm (3 wire) as like as Positioner.The meter supports Field Calibration function. It can be calibrated with sensor (Potentiometer) to meet machinery structure.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
Product
12DI/6DO IoT Modbus/SNMP/MQTT Ethernet Remote I/O
ADAM-6050
-
12ch digital input(counter)/6ch digital output(pulse output)Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful API,ASCIIGCL to perform basic logic control rulesPeer-to-Peer function to map I/O statusCloud access: Data update to AzureBuilt-in web serverWatchdog timer to recover the system
-
Product
Total Tank Level System
-
The Total Tank Level System is an intrinsically safe and explosion proof level sensor with several communication options. Outputs include Modbus RTU digital, dual 4-20mA and HART. The Modbus version is offered in a single housing and the 4-20mA and HART output product features a dual compartment housing and display.
-
Product
16DI IoT Modbus/SNMP/MQTT 2-Ports Ethernet Remote I/O
ADAM-6251
-
16ch digital input(counter)Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCIIGCL to perform basic logic control rulesCloud access: Data update to AzureAuto-bypass function to ensure daisy-chain data transmissionPeer-to-Peer function to map I/O statusBuilt-in web serverWatchdog timer to recover the system
-
Product
ANSI X3.28 to Modbus RTU Converter
Model 2399
-
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
Product
8FE Managed Ethernet Switch Support Modbus/TCP,-40~75℃
EKI-5528I-MB
-
8 ports Fast Ethernet RJ-45 (EKI-5528/I-MB)Entry-Level Managed SwitchIXM function enables fast deploymentManagement: SNMP v1/v2c/v3, WEB, Standard MIB, Private MIB
-
Product
Free Serial Port Tools
-
*The clever terminal program for serial port and field-bus communication.*Build your own sending dialogs and create customized user interfaces *Simulate field-bus telegrams *Play Modbus ASCII/RTU master with predefined Modbus function dialogs
-
Product
4DI/4 Relay Output Modbus RTU Remote I/O
ND-6160
-
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
Product
ANSI X3.28 To Modbus RTU - Serial To Modbus RTU Converter
-
Designed for legacy systems where there is a need to replace older X3.28 protocol Controllers and with new Modbus RTU Controllers. The Model 2399 provides ANSI X3.28 to Modbus RTU Conversion without changing the existing system software. The 2399 also provides serial control of Modbus RTU devices for new applications that want the ease of using simple ASCII commands when controlling Modbus RTU devices.
-
Product
4 Digit Temperature Meter (5 Channels)
CM1-TX5
-
RS-485 Modbus RTU protocol (with communication LED indicator)RS-485 address 1~255Communication Baudrate 9600, 19200, 38400, 57600, 115.2KParity check N81, N82, E81, O81Input 5 channels of signal selectable:thermocouple/PT100.5 channels of input can be set to play 1~10 seconds loop display.1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself.5 channels of input signals with LED unit cycle display.Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system.Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoringCan be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel
-
Product
4AO/4DI IoT Modbus/SNMP/MQTT 2-Ports Ethernet Remote I/O
ADAM-6224
-
4ch analog output/4ch digital inputProtocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCIIGCL to perform basic logic control rulesCloud access: Data update to AzureAuto-bypass function to ensure daisy-chain data transmissionPeer-to-Peer function to map I/O statusBuilt-in web serverWatchdog timer to recover the system
-
Product
8DI/7DO IoT Modbus/SNMP/MQTT 2-Ports Ethernet Remote I/O
ADAM-6250
-
8ch digital input(counter)/7ch digital output(pulse output)Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCIIGCL to perform basic logic control rulesCloud access: Data update to AzureAuto-bypass function to ensure daisy-chain data transmissionPeer-to-Peer function to map I/O statusBuilt-in web serverWatchdog timer to recover the system
-
Product
Industrial Gas Detectors
-
Seitron designs and manufactures detectors for methane, LPG, gasoline vapours and carbon monoxide (CO) for commercial and process industry use. Our detectors provide three communication protocols 4..20mA, Modbus and S-Bus (a proprietary protocol derived from Modbus). You can also choose between two types of housings: polycarbonate for industrial use or ATEX-certified for the installation of detectors in ATEX-classified areas.
-
Product
Temperature & Humidity Transmitter
HTO
-
- CO2 measuring element: NDIR Sensor 2- CO measuring element: Electrochemical sensor- Temperature/Humidity sensing element : CMOS sensor- Analog output option:4~20mA or 0~10V- Communication output option:RS485 Modbus RTU- Configured by PC with free software via USB cable (option)- Present value offset adjustable- Inside buttons for adjust output parameters- LCD backlight color to Indicated CO/CO concentration 2- Temperature measuring range can be -50~100℃ via USB console port to setting
-
Product
8 RTD/6DI/8DO IoT Modbus/OPC UA Ethernet Remote I/O
ADAM-6315
-
OPC UA empowers Modbus I/O users to access the industrial IoT world.OPC UA I/O links SCADA and the cloud without the need for gateways, accelerating OT and IT convergence.Hardware and software double security levels to prevent being hacked.Cost-effective: high I/O density and daisy-chaining solution saves cost.
-
Product
8Thermocouple Modbus RS-485 Remote I/O
ADAM-4018+
-
8ch thermocouple(can be set to current)Protocols:Modbus RTU,ASCIIWatchdog timer to recover the system3000VDC isolation protectionWiring burned-out detection function
-
Product
Modbus or Laurel ASCII ProtocolSerial Output DIN Rail Transmitters
-
Laureate TM Series serial output transmitters can be jumpered for two signal levels: RS232 or RS485. Two serial protocols are selectable in software: Modbus or Laurel's Custom ASCII.Modbus protocol operation is fully compliant with the Modbus Over Serial Line Specification V1.0 (2002) for 2-wire, half-duplex connection.
-
Product
Residual Current Protection
-
Solutions to ensure the safety of people and installations against any ground currents. Available with ultra-immunized system as an essential solution to avoid financial losses due to outages caused by inadvertent trips. Specially designed to protect industrial installations in AC networks (type A), installations with both AC and DC components and DC-only installations (type B). Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
Product
High-power DC Electronic Load (6kW~60kW)
FT68200A/AL/E Series
-
Shenzhen FaithTech Technology Co., Ltd.
FT68200 series high performance high-power DC electronic load provides three voltage ranges 150 V/600 V/1200 V, maximum current 2400 A per single unit, stand-alone power from 4 kW to 60 kW, expandable up to 600 kW, 10000A by master-slave paralleling. Ultra-high power density, 6kW is with only 4U height. Wider operating region, faster dynamic frequency, as well as transient mode, OCP/OPP test, sequence test, automatic test and battery discharge test functions greatly enhances its test strength and expands application coverage. Furthermore, two times instantaneous overpower loading capability can effectively reduces user’s test cost. Built-in standard RS232, RS485, LAN, USB (serial), optional GPIB and CAN interface, supports SCPI, ModBus RTU and CANopen protocol, which facilitates system integrators. FT68200 series has full protection functions, which can be applied to power battery discharge, DC charging station, charging piles, charging pile modules, vehicle On Board chargers (OBC), high-power switching power supplies, power electronics and other power electronics products.
-
Product
OPC Server
-
An OPC sever (OLE for Process Control) provides IO and more devices to communicate with a wide range of HMI/SCADA software packages residing on a host. Advantech''s OPC server for ADAM and modbus devices features OPC DA (data access) and AE(alarm and events) client for the rapid testing.
-
Product
8AI Robust Modbus RS-485 Remote I/O
ADAM-4117
-
8ch analog input(voltage or current)Operation temperature:-40~85°C,Power input:10VDC~48VDCNoise protection: 4kV surge(power),4kV EFT,8 kV ESD protectionInterface: RS-485/USB3000VDC isolation protectionLED indicator to monitor I/O status
-
Product
8AI IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O
ADAM-6217
-
8ch analog input(voltage or current)Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCIIGCL to perform basic logic control rulesCloud access: Data update to AzureAuto-bypass function to ensure daisy-chain data transmissionPeer-to-Peer function to map I/O statusBuilt-in web serverWatchdog timer to recover the system





























