Standard Transformers
-
Product
Current Transformers
-
Ultra-precise electrical metrology devices designed to measure high AC and DC currents with exceptional accuracy in the parts-per-million (ppm) range.
-
Product
Control Transformers
-
Osborne’s Control Transformers are commonly used to step down primary circuit voltages to lower voltages to be used for control circuit applications. These units set the standard for premium, high performance, hand crafted control transformers. Your customers will appreciate your decision to work with the quality and reliability of Osborne Transformer’s control transformers.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1R1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard Series
-
TPC-100W Series offers versatile web terminals in 7", 10", 15.6" and 21" displays, designed for factory control systems
-
Product
Standard CT
800A
-
• High accuracy of 800/5A (0.05%) • multiple ratios • Various Current ratings
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1R1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1J-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
2 Channels, MIL-STD-1553, Dual Redundant, Transformer Coupled, Assisted Mode Capable (AMC)
FTB
-
MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed for use with military avionics, but has also become commonly used in spacecraft On-Board-Data-Handling (OBDH) subsystems, both military and civil. It features a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
SiTek Standard PSD
1L20_CP3
-
The SiTek Standard PSD (Position Sensing Detector) has high resolution, fast response and outstanding linearity. It is used in a wide variety of applications, most of them utilizing light sources in the visible or near-infrared part of the spectrum. The spectral range covers the region 400 - 1100 nm. Thanks to SiTek's proprietary AR-coating, optimized around 860 nm, a reflection loss of only 2% is achieved around the responsivity peak. Most of the detectors have a cover window to avoid handling damages.
-
Product
Standard Step Tablets, Gray Scales & Density Reference Charts
-
Standard Step Tablets, Gray Scales & Density Reference Charts are available in a wide variety of patterns, designs and sizes to fit a multitude of today’s application needs. Our gray scales and density patches are measured on a variety of NIST traceable instrumentation, including some of the most sophisticated microdensitometers available to the industry. They are imaged on either Photo Paper (RM) or Film (TM) to function for reflective or transmissive applications.
-
Product
Current Transformer Testers
-
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
Product
Isolation Transformers 230V
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
Product
Standard Optical Interleaver
-
An innovative technique for expanding the number of channels per fiber involves an optical device, called an optical interleaver. For example, in most DWDM equipment, the standard channel spacing is 100 GHz. But spacing the signal-carrying frequencies every 50 or even 25 GHz can double or even quadruple the number of channels per fiber. This job is accomplished by an optical interleaver. Such a device takes two multiplexed signals with 100-GHz spacing and interleaves them, creating a DWDM signal with channels spaced 50 GHz apart. The process can be repeated, creating even denser composite signals with 25-GHz or 12.5-GHz spacing. The signals at the receiving end are recovered with the same devices used as splitters or optical de-interleavers. Thus, devices and/or networks can be upgraded without requiring that all devices be upgraded, or network bandwidth can be increased.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Transformer Test Equipment
-
KV Hipot Power Test Equipment Co.,Ltd
Transformer Test Equipment. Ensure that a transformer meets performance and reliability requirements, from the production line to after a repair or upgrade, when a major disruptive event occurs such as a lightning strike, or for preventive/predictive maintenance.
-
Product
Split Core Current Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4-S
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Transformer Turns Ratio Meter
TTRM 101
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Capacitance Standard Set, 0.01uF To 10uF
16380C
Capacitance Meter
The 16380C is a standard capacitor set consisting of three precision capacitors - 0.01uF (16385A), 0.1uF (16386A), 1uF (16387A),and an optional 10uF (16388A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Standard Voltage 9 Pin D-Type Cables - Connector to Connector for Pickering Products
-
The connector to connector cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
CANbus Controller Standard Interface
PCI360
-
The PCI360 CANbus controller PCI card is based on the SJA1000. The SJA1000 provides an interface to the popular CANbus that support both standard (11-bit) and extended (29-bit) identifier messages. LEDs provide diagnostics information.The CAN network is a serial communication protocol which efficiency supports distributed real-time control with a high level of reliability.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
DGA Monitor for Transformers
OPT100 Optimus™
-
The Vaisala Optimus OPT100 DGA (Dissolved Gas Analysis) Monitor for Transformers gives you out of the box performance, completely eliminates false alarms, and offers the best long-term stable measurements of any device on the market – all with no maintenance. Spectral scanning provides selective gas measurement.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I40-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02