Standard Transformers
-
Product
Zero Phase Current Transformer
MZL-30
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
Product
VXI Rubidium/GPS Frequency Standard
3352A Series
-
The Racal Instruments™ 3352A Rubidium frequency standard module and the 3352A-GPS, its GPS-disciplined companion, set a new standard for high density functionality in a single width VXI module. Using ANSI Standard M-Module building blocks, the 3352A series integrates the functions of a Rubidium oscillator and clock distribution together with an optional trigger distribution module and an optional digital I/O (DIO) module.
-
Product
Current Transformer with Open Core
TCP
-
Lifasa - International Capacitors, SA
The TCP series is designed for installations in operation. It has a removable core that allows its connection without interrupting the power supply.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Phase Angle Voltmeter, Industry Standard
2250A
-
NAI's 2250A Phase Angle Voltmeter is the most accurate and versatile AC measurement tool in the Synchro/Resolver and LVDT/RVDT marketplace. Considered the industry standard and based on the latest DSP and FPGA technologies, the 2250A substantially extends and simplifies the capabilities of the legacy 2250 model.
-
Product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Transformer Resistance Testing
-
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the Megger Transformer Ohmmeter (MTO) series of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
-
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Fully Automatic Transformer Oil Test Set
-
1. Test as per International standards NMC insulating oil testers are fully automatic micro controller based system,completely self-contained,compact and portable giving smooth variable test voltage from 0 to 60, 80, or 100 kV for testing the dielectric strength of insulating oil in accordance with all international standards like IEC156/IS6792/ASTM D 1816/ASTM D877/ UNE 21 specifications.2. Auto mode NMC insulating oil testers are fully automatic type.1) IEC-156, IS6792, ASTM D 877, ASTM D 1816, UNE 21.2) Withstand Test A3) Withstand Test B4) 5 Minute Test5) User defined3. 100 Test results storage capacity NMC insulating oil testers has a storage capacity of 100 test results which can be recalled and printed.4. LCD display NMC insulating oil testers use LCD for easy readability of the BDV test results.5. Built in printer The printer used is a thermal paper print outs.The paper rolls can be easily installed by any person.6. User Friendly RS 232 Interface RS 232 interface is very easy to use to communicate stored data which can be saved in text format.7. Safety protection Safety interlocks are provided on the test chamber.Zero interlock protection to ensure operator safety.8. Accurate Performance The kit not only has all basic functions of an insulating oil tester but also has unique features that are seldom seen in similar products. For e.g. PROOF test A, PROOF test B, 5 Minntes test, LCD to display all test data.It ensures high work efficiency and reliability in any tough environment.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1R1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard Transmitter
Tipix 2200
-
The TIPIX 2200 is a transmitter purposely designed for deep Induced Polarisation or Resistivity sounding investigations. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers. This entry-level instrument has been designed for an ease of use and for a good productivity together with a strong protection against misuse. This very robust device has proven to be reliable even in very cold weather (up to -40°C) or in wet environment. It is able to inject up to 2200W in the soil and to inject up to 13A, so that it is suitable, even on conductive soils, to measure resistivity and IP at medium range depths. It is powered by standard generator.
-
Product
Instrument Transformer Calibrators
MRL 22
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2262AG-1C1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
CDPH Standard Method for VOC Emissions
-
Underwriters Laboratories Inc.
The Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions From Indoor Sources Using Environmental Chambers, an expanded standard for what is commonly known as California Specification 01350, is one of the most widely used standards to evaluate building and interior products for low chemical emissions.
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1V-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1C1S
-
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
High Voltage Standard
HVS
-
The HVS uses precision matched resistors for high accuracy; it is a modified Park divider structure.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2E
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2D
-
Current Rating (Amps): 5Average Probe Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64Resistance (mOhm): 35
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2LB-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard Voltage 9-Pin D-Type Connector & Cable Accessories
-
The Standard Voltage 9-Pin D-Type connector is used on PXI switching products to provide a low density connector solution. Connection solutions for modules with High Voltage Rating D-Type connectors are also available.
-
Product
Separating Transformers
-
Is a transformer in which the primary and secondary windings are galvanically/electri- cally separated with basic insulation. Isolating transformer: A separating transformer with a protective partition between the primary and secondary windings.
-
Product
Transformers (Murata Power Solutions Products)
-
Murata transformers are ideally suited to high-frequency designs. The products come in a variety of industry-standard packages and can be used in applications where impedance matching, voltage conversion, isolation and current sensing may be required.
-
Product
IEC Potential Transformer Burdens
-
• Burdens for IEC specifications rated for various input voltages available • 2.5 to 207.5 VA at 0.8 PFIEC Potential Transformer Burdens
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Standard Gain Horn Antenna
SAS-586
-
This Standard Gain Horn Antenna will provide reliable, repeatable measurements. An ideal solution and a standard workhorse of any EMC test house for compliance testing. Features: 12.4 GHz to 18 GHz, Individually Calibrated, FCC, MIL-STD, VDE and TEMPEST Testing.
-
Product
Current Transformers
-
Rishabh Instruments Pvt. Ltd.,
Rish Nano CT is a very reliable, efficient and robust current transformer for measurement of AC current. It provides 100 mA AC output. It can be used in Circuit breakers. Earth Leakage Protection.
-
Product
Qseven® Standard Size Module With Intel® 6th Gen. Atom® X6000 Processors (Formerly Elkhart Lake)
Q7-EL
-
The ADLINK Q7-EL is a Qseven module that supports Intel Atom® x6000 (x6425RE, x6414RE, x6413E) processors (formerly Elkhart Lake) with integrated Intel® UHD graphics and high-speed interfaces. With mechanical dimensions of 70mm width, 70mm length, and 2.3mm of overall height, Qseven ranks as one of the smallest COM standards currently available. Q7-EL modules support up 16GB LPDDR4 memory, up to 256GB eMMC storage and are also available with rugged operating temperature range and low power envelope, making them a perfect match for mission critical fanless edge computing applications that require safety and reliability at all times.