Scope T&M Pvt, Ltd.
Design electronic testing instruments that could work in the hostile electrical and electro-magnetic environment prevalent in charged sub-stations.
- 91-22-4344 4244
- 91-22-4344 4242
- 402, Aurus Chamber,
Annex A, S.S. Amrutwar, Marg,
Worli,, Mumbai 400 013
India
-
Product
Insulation Resistance Measurement
MD 5KVr
-
The digital insulation tester model MD5KVR is TENTECH's cutting edge insulation analyzer equipment and it is one of the most complete and sophisticated available in the international market. A software allows for further analysis of tests results, including features such as graphical representation and automatic report generation. Its proven technology provides safe, reliable and accurate measurements of insulation resistances up to 5 TΩ, with 4 preselected test voltages, 500 V -1 kV - 2,5 kV - 5 kV. Other test voltages, from 50 V to 5 kV, can be selected in 25 V or 500 V steps.
-
Product
Insulation Tester Calibrator
DecR
-
SCOPE offers High Resistance, High Voltage Decade Resistance Box - DecR. It contains number of smartly configured precision resistors. They are arranged in such a way that user can obtain desired resistance value by selecting appropriate decade switches. DecR is designed using the high quality specially selected resistors. These range of high ohm resistance decades are ideal for variety of applications, having a voltage rating up to 5 kV. It covers the resistance range from 1 kilo ohm to 1 tera ohm. DecR can also be customized as per requirement. DecR is housed in a rugged case and available in 3 / 4 / 6 / 9 decades or in binding post configuration
-
Product
Circuit Breaker Testing Equipment
CB SCOPE
-
SCOPE introduces CB SCOPE – Loco Vaccum Circuit Breaker Test System; the ultimate solution for testing Loco Circuit Breakers of all types. CB SCOPE is the most complete analyzer for checking the dynamic performance of LOCO VCB’s.
-
Product
CT Polarity Tester
DIR CT
-
SCOPE proudly introduces Dir CT, a CT Polarity Tester specially designed to verify correctness of polarity of current transformers cores in live EHV switchyards. Polarity test is one of the most common yet crucial tests required to be done on current transformers by commissioning as well as maintenance engineers. Even though it is commonly conducted check, there was no all in one simple tool available for this measurement. DIR CT fills this void to perfection, it is expected to significantly reduce the time taken for polarity checks on numerous CT in sub-station, especially during commissioning of new sub-stations
-
Product
Pre- Locator
CFL PL4
-
CFL PL4 Power Cable Fault Locator is a portable, easy to use cable fault pre-location instrument. It uses the Time Domain Reflection (TDR), Secondary Impulse Method / Multiple Impulse method (MIM) and Impulse Current Method (ICM) on low, medium and high voltage cables. Its measuring ranges enable pre-location on cable lengths from 500 m to 64km.
-
Product
Insulation Resistance Measurement
MI20KVe
-
The MI-20KVe High-Voltage insulation tester is a truly portable device that allows the measurement of insulation resistances using test voltages up to 20 kV.
-
Product
Traveling Wave Fault Locator
XC-2100E
-
XC 2100E, a Fault Location System based on principle of travelling wave detection is the solution to above problem. It can detect not only permanent fault, but also transient fault within one tower span accuracy (with best accuracy of ±50 meters). It is a kind of Line Monitor for continuous monitoring of transmission lines and gets triggered whenever travelling waves are generated on line due to switching, lightening or fault.
-
Product
Surge Arrestor Testing Equipment
SA 30i+
-
SA 30i+, the wireless Leakage Current Analyser from SCOPE is a State of the Art, On-line test system for Residual Life Assessment of Metal Oxide Surge Arresters. The instrument measures and directly displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current. It provides system harmonic compensation as per IEC 60099-5-B2. It provides Corrected Resistive Leakage Current after applying correction factors for change in system voltage & temperature.















