Current
See Also: Direct Current, Alternating Current, Resistivity, Flow, Inductance
-
Product
Through Hole Type AC Current Sensor
CTF-50B
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*Suitable for current measurements of feeder cable.*Measuring range:AC 0.1A~50A.
-
Product
LIV – High-power Laser Diode Testing
-
An important aspect of the development and manufacture of laser diodes is the so-called laser diode characterization, or laser IV curve. By applying increasing current to the laser diode so it that emits light, the optical output is measured together with the voltage drop across the diode element. The resulting LIV curve reveals important clues about the quality of manufacture and the performance of the laser diode, enabling a pass/fail decision to be met.
-
Product
Accelerometer Simulator
MTN/8302
-
The MTN/8302 is a battery-powered unit designed to simulate a constant current type accelerometer. It enables test and calibration of vibration monitoring equipment such as the Monitran MTN/6000 series.
-
Product
PXI Solid State Switch Module, 3xSPST, 10 A, Hardware Interlock
40-182A-012-HI
Switch Module
The 40-182A-012-HI has 3 off high current SPST switches with hardware interlock in one PXI slot and is part of our range of high power solid state switching solutions.
-
Product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74T80-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-2
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Surge Generators
Hybrid
-
Surge pulses occur due to direct or indirect lightning strikes in a circuit or by switching transients caused by switching inductive loads or short circuits. This leads to currents or electromagnetic fields causing high voltage or current transients. Surge voltages and currents can reach several thousands of volts and thousands of amperes. Our following Surge generators simulate these disturbances for all the necessary level in accordance with IEC / EN 61000-4-5 and IEC / EN 60060.
-
Product
Alternate 0.99 (28.00) - 6.00 (170.00) Long Travel Bead Probe
BPLT-25C-6
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1J-6-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Oscilloscopes
-
A device for viewing oscillations, as of electrical voltage or current, by a display on the screen of a cathode ray tube.
-
Product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
-
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
Product
Rackmount Models
-
All our rack mount models feature bright and accurate 1 inch high LED readout of voltage and current that is readable from across the room in any lighting condition from daylight to full darkness.
-
Product
DC Clamp Meter
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Is used to measure the DC currents.
-
Product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25L-8
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Difference Amplifiers
-
A difference amplifier is a special purpose amplifier designed to measure differential signals, otherwise known as a subtractor. A key feature of a difference amplifier is its ability to remove unwanted common mode signals, known as common mode rejection (CMR). Unlike most types of amplifiers, difference amplifiers are typically able to measure voltages beyond the supply rails, and are used in applications where large dc or ac common-mode voltages are present. They are ideal for current and voltage monitoring. Analog Devices offers a range of difference amplifiers, optimized for low distortion, low power, or high voltage performance.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Ground Bond Tester
260 Series
-
Our 260 Series makes Ground Bond testing simple. We offer two models so that you can have a simple and easy-to-use Ground Bond tester that provides the output current you need to satisfy NRTL specifications. With an intuitive interface that allows you to set-up a test in seconds and practical security settings, our 260 Series can easily be deployed in both laboratory and production line environments.
-
Product
AstroAI Digital Multimeter
10000
-
AstroAI Digital Multimeter 10000 Counts TRMS Auto-Ranging Color LCD Screen Voltmeter, Fast Accurately Measures Voltage Current Amp Resistance Continuity Duty-Cycle Capacitance Temperature
-
Product
Signal Amplifier
A10160
Amplifier
Model A10160 is an ultra-small footprint, wideband, DC coupled amplifier designed for high frequency, high current, signal amplification. With a high bandwidth of 45MHz, 34Vp-p into 50 ohms and up to 10W output power, the A10160 is the ideal complimentary amplifier to any signal source that needs a supporting power boost for demanding applications.
-
Product
PXI Load Resistor Module 40 Ohm to 295 Ohm
40-292-011
Load Resistor Module
The 40-292 module is able to simulate the common short circuit and open circuit conditions that can be experienced in a system due to faulty wiring or sensors. The short circuit position is fully thermally protected and provides a short circuit current limit. The series open switch provides an automatic current limit through the resistor chain and is thermally protected.
-
Product
Alternate 1.10 (31.18) - 7.20 (204.00) Switch Probe
TSP100-C100-2
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25L-6
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Outdoor AGC Optical Node
SR814B
-
Hangzhou Softel Optic Co., Ltd.
Based on plenty of experience about CATV HFC network optical fiber transmission equipment, we developed SR802, SR802B, SR804, SR804B series field optical receiver which is two-way optical receiver; They are mainly used in long-distance optical fiber transmission of TV image signal, digital TV signal, telephone voice signal and data (or compressed data) signal. We are innovating the product technology, rebuilding the line structure and Improving the process quality since we developed the first CATV optical receiver successfully in 1995; The current WR series optical receiver are not only of the lead position in domestic level regarding line technique, but also the same as imported product regarding technological quality; We have developed a variety of different models for users to choose models.
-
Product
Ultra Slim DIN Rail AC-DC Power Supplies
DPC Series
-
XP Power today announced the DPC series of highly efficient ultra slim DIN rail AC-DC power supplies. Available in 30, 50 and 70 Watt single output models, they all accept the universal input range from 90 to 264 VAC without the need for any input selector switches. Taking up significantly less space on the rail by being up to 44% slimmer than current generation DIN rail power supplies, the 30 Watt DPC30 measures just 90.0 x 100.0 x 22.5 mm (3.6 x 3.94 x 0.89 inches). Also, the 50 Watt DPC50 measures 90.0 x 100.0 x 30.0 mm (3.6 x 3.94 x 1.18 inches) and the 70 Watt DPC70 measures only 90.0 x 100.0 x 40.5 mm (3.6 x 3.95 x 1.59 inches). Offering all the popular nominal output voltages from + 5 to + 48 VDC, the single output can be adjusted up to + 30% of stated nominal, model dependant, in order to accommodate non-standard voltage requirements or to make up for line losses. All models feature a green LED to indicate output on.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Py-Screener
-
The Py-Screener™ system is designed to screen for phthalate esters in polymers. The use of phthalate esters in toys and food packaging is currently restricted. Moving forward, they are expected to be regulated as restricted substances under the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS (II) Directive) in Europe. The pyrolyzer GC/MS (Py-GC/MS) is used to selectively detect and quantify phthalate esters thermally extracted from samples. This screening system consists of a sampling toolkit, special standards, and special software and can be easily operated even by novices.
-
Product
DC Resistance and Current Measurement System
-
DC Resistance and Current Measurement System including: 6622A Series Bridge, 6634A Temperature Stabilized Resistance Standards, 6664C Scanner(s), world’s most precise and stable 6623A Precision Current Source/Range Extender, Wired Equipment Rack, and Bridgeworks Software.
-
Product
Light 0.75 (21.00) - 2.00 (57.00) Bead Probe
BTP-25C-2
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
96 Sink/Source
YAV90096
Digital I/O
Selectable voltage and current, comparation and measurement Drive sink or source up to 32 mA per channel Maximum voltage in output selectable from 9 to 24 VDC Possibility to use I7Os in parallel Pin voltage comparator with logic readout at fix +4VDC 10-bit resolution pin voltage measurement with CAN bus value readout Build-in editable test steps sequence (test script) Size: form G
-
Product
Linear Actuators
Electrak 1LL
-
Thomson continues its strong support of our current customers through our legacy product families. We encourage our customers to contact our sales application teams to discuss new and improved product offerings. The Electrak 050 actuator is our recommended replacement for the legacy actuator Electrak 1LL.





























