Turn Ratio
-
Product
Transformer Turn Ratio Meter
-
A specialized, highly accurate diagnostic instrument used to measure the ratio of primary to secondary winding turns in transformers.
-
Product
Transformer Turn Ratio Instrument
ART-3D
-
The ART-3D is high precision instrument designed to measure ratios, magnetization currents, phase-shifting in power transformers, distribution transformers, potential and current transformers, in conformity to IEEE C57.12.90 and CEI/IEC 60076.
-
Product
Transformer Turns Ratio Meter
TTRM 302
-
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
Product
Multiplexer For Transformer Testing
MUX-R
-
Raytech Multiplexer MUX R is designed to drastically reduce cabling time and increase test performance. It is made to be used with Raytech Winding Resistance and Turns Ratio Meters. Any MUX R configuration can be easily controlled by a Winding Resistance Meter touch panel or by remote.
-
Product
Transformer Turns Ratio Meters
-
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
Product
200KHz AUTOMATIC TRANSFORMER TEST SYSTEM
VE2729XAU
-
Its a Microprocessor Based 200KHz Automatic Transformer Tester with inbuilt 20 Pin Channel Scanner for Automatic Switching and Testing Coils & Transformers (Ferrite) with Max. 20 PINS. Test Parameters : -> Inductance (L)-> Leakage Inductance (Lk)-> Capacitance (C)-> DC Resistance (Rdc)-> AC Resistance (Rac)-> Turns Ratio with Winding Polaity-> Quality Factor (Q)-> Impedance (Z)
-
Product
Automatic Transformer Tester
SS3250 / SS3252 / SS3302
-
Automatic transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process, with high stability and high reliability. With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, transformer's turn ratio and turn number with more precise measurement.
-
Product
HV Test Set
-
Beijing GFUVE Electronics Co.,Ltd.
Used for testing transformer, circuit breaker & switch etc by engineer, for example TTR tester can test transformer turns ratio.
-
Product
Turns Ratio Testers
TRT Standard Series
-
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
Product
3 Phase Voltage Extension To Turns Ratio Meter
T-REX
-
The Raytech three phase voltage system option T-Rex is an optional system accessory for 3-Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III). T-Rex was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
Product
Acoustic Imager
-
Can be used for quick on-site testing of current transformers in metering installations. They are designed and manufactured to test transformers’ primary current, secondary current, and turns ratio and identifies phase type and polarity.
-
Product
ATTR Auto Transformer Turns Ratio Tester
-
Chongqing Assen Power Equipment Co., Ltd
Transformer turns ratio tester is a new type of fully automatic tester that uses modern electronic technology to measure the ratio of single-phase and three-phase transformers, and does not require any manual “zero” balance.
-
Product
Transformer Turns Ratio Meter
TTRM 102
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Transformer Turns Ratio Testers
-
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
Product
Turns Ratio Testing
-
The transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Megger’s range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
-
Product
Large Current 1000A Primary Current Injection Test Set
TEST-901
-
Beijing GFUVE Electronics Co.,Ltd.
TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
-
Product
3 Phase Voltage Extension To Turns Ratio Meter Rack
T-REX R
-
The Raytech three phase voltage system option T-Rex R is an optional system accessory for 3- Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III R). T-Rex R was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
Product
Transformer Turns Ratio Meter XTRM-3
XTRM-3
-
The Motwane Manufacturing Company
Your product description goes here. Motwane’s transformer turn ratio meter XTRM-3 is a new generation fully automated kit to measure turns ratio, voltage ratio, ratio error, phase displacement & excitation current in a transformer. It automatically detects the transformer vector group. Its user-selectable test voltage feature provides for testing various ratings of power transformers.
-
Product
Primary Current Injection Testers
-
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Power Transformer
-
Transformer turn ratio meter is special designed for power transformer (single phase & three phases) and instrument transformer testing, suitable for testing in substation, transformer manufacturer, meter manufacturer. It helps to detect faulty transformer winding and tap changer position. It’s fully automatic device, can recognizes winding connection and vector group number of transformer winding. The user only need connect measuring cable and press start button and come out the test result.
-
Product
Transformer Turns Ratio Meter
-
International Biological Laboratories
Transformer Turns Ratio Meter is compact in size and is capable to measure actual turns ratio of different types of transformers like Distribution, Power, CT, PT, Auto-transformers, Control & Measuring transformers etc.
-
Product
Turns Ratio Meter 1 Phase
TR-1 / TR-1P
-
Raytech Single Phase Transformer Turns Ratio Meter TR-1/P was designed to be a rugged and reliable automatic transformer Ratiometer. This system has a high degree of accuracy and will test ratios to 4000:1. The design of this test system is based upon the popular Raytech Automatic Three Phase test set: TR-Mark III.
-
Product
Transformer Turn Ratio Tester
KVBB-II
-
KV Hipot Power Test Equipment Co.,Ltd
KVBB-II Transformer turn ratio tester is used to check turn ratio of transformer, tap switch situation, whether transformer interturn is short circuit and transformer can run in parallel or not.
-
Product
Turns Ratio Testing
-
Weshine Electric Manufacturing Co., Ltd
1. Full three-phase sinusoidal inverter power output, output voltage is automatically adjusted, with soft start and soft stop functions, so the test speed is fast and the accuracy is high.2. The instrument has single-phase, three-phase, Z-type transformers, voltage transformer ratio, group, polarity test functions.
-
Product
Automatic Transformer Observation System
ATOS
-
Raytech – The World leader in design and manufacturing of high-quality precision measuring instruments and systems, offering flexibility and versatility. Our modular Automatic Transformer Observation System (ATOS) allow you to create a unique and custom solution for any application. ATOS is designed to drastically reduce measuring time and increase test performance, without losing accuracy compared to individual test instruments. With the choice of up to three Multiplexers (primary, secondary, and tertiary), three Winding Resistance Meters, each with three maximum current range options (up to 15A, 50A, or 100A), Turns Ratio, and Integrated power security and safety panel (ISU R), Raytech can create a system with your needs and budget in mind.
-
Product
50Hz-100kHz LCR Meter
11022/11025
-
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
Product
Transformer Turns Ratio Meter
-
We are considered as one of the leading manufacturers and exporters of Transformer Turns Ratio Meter With/ Without Phase. The equipment is widely used in power generation and engineering industry for testing of transformers. We engineer and develop this testing equipment in accordance with industry standards using best grade components and raw materials. This Transformer Turns Ratio Meter With/ Without Phase can be also optimized according to client's specific requirement. We offer this testing equipment at competitive price.
-
Product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
-
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.