Hilkar
Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkiye
-
Product
Anti-Islanding Load Banks
AI-Series
-
AI-series anti-islanding load banks containing purely resistive, inductive, or capacitive load, have segmented combination control of power input, and can simulate a variety kinds of power loads to meet the grid-connected inverter full load test requirements.
-
Product
Air Core Neutral Grounding Reactors
-
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
Product
Motor Termination Units
-
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.
-
Product
Resistive Load Banks
R Series
-
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
Product
Air Core Motor Starting Reactors
-
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
Product
Reduced Voltage Motor Starting Panels by Reactors
-
A method to limit motor starting current is a series reactor. Iron core or air core reactors can be used for starting purposes. If an air core is used for the series reactor then a very efficient and reliable soft starter can be designed which is more suitable for high MW ratings of synchronous/induction motors at MV levels. The reactors are designed with taps.
-
Product
Radiator Mounted Load Banks
RD-Series
-
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
Product
LCL Filters
-
LCL Type Harmonic Filter Modules are used to filter out the input current harmonics of the Motor Drives having six-pulse diode/thyristor rectifiers, where harmonic current distortion exceeds the limits defined in standards.
-
Product
Motor Starting Auto-Transformers
-
Motor Starting Auto-Transformers reduce the inrush current by stepping down the applied voltage during the start-up operation of induction and synchronous motors.
-
Product
Air Core Test Lab Reactors
-
Test Laboratory Reactors are designed for high voltage and high power test laboratories. They are designed to withstand the most extreme electrical service conditions during test periods. Design techniques are implemented in accordance with the most demanding service conditions. These reactors are used for various purposes in test laboratories such as current limiting and synthetic testing of circuit breakers, capacitor testing, artificial line simulation etc.
-
Product
Air Core Line & Load Reactors
-
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Product
Iron Core Current Limiting Reactors
-
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
Product
Anti-Condensation Heaters
-
Anti-Condensation Space Heaters are designed to maintain the temperature of an electrical enclosure. Anti-Condensation Heaters are used for elimination of water vapor contained inside the enclosures. They also provide frost protection by keeping the internal temperature of electrical enclosure above the freezing temperature. The Anti-Condensation Space (Panel) Heaters prevent condensation through convection.
-
Product
Inductive Load Banks
L-Series
-
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
Product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
-
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.