Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
Data Acquisition and Control System
DAQ 7000
Data Acquisition System
data acquisition and control system that provides connectivity, signal conditioning and modular I/O for variety of sensors or signals, and it is an ideal DAQ for field deployment.
-
Product
PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module
781369-01
Analog Input Module
204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
Analog Input Modules
-
The modules provide direct connection to a wide variety of sensors and annunciators. They perform all signal conditioning and linearization and contain no pots or DIP switches. All user-selectable settings, such as ranges are stored in nonvolatile EEPROM, which maintains these values even after power is removed.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-02
Strain/Bridge Input Module
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
USB-4431, 102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 4-Input/1-Output Sound and Vibration Device
780164-01
Sound and Vibration
The USB-4431 is designed for sound and vibration measurements. Input channels incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones. The four USB-4431 input channels simultaneously digitize input signals. The analog output (AO) channel is ideal for stimulus-response tests and can be synchronized to the AI channels.
-
Product
2 to 8 Channel Anti-Alias Low-Pass Filter Card
AAF-1
-
The AAF-1 is a multi-channel anti-alias low-pass filter board designed for front-end signal conditioning in PC-based or stand-alone 12-bit A/D conversion systems.
-
Product
RF Microwave Switch Matrices
-
RF Microwave Switch Matrices provide automatic routing of RF microwave signals between test instrumentation and the unit under test (UUT). They provide consistent signal paths, enable automation of tests, and often include signal conditioning.
-
Product
2-18GHz Instantaneous Frequency Measurement Unit
DR058-F2
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.
-
Product
16 Bit 250 KS/s ADC With 16 Channel Multifunction Digital I/Board And Bridge Signal Conditioner
-
The CP246 is a single-width, 6U, CompactPCI/PXI module with 8 channels of Bridge Signal Conditioning feeding 8 independent 16-bit Analog to Digital Converters (ADC). This single-width solution incorporates both signal conditioning and ADC to eliminate the need for complex field wiring.
-
Product
Charge Amplifiers & Signal Conditioning
-
The use of charge amplifiers alongside piezoelectric charge output sensors is still widespread in many industries. This is due to the rugged and high temperature capabilities of the sensors. There are many challenges in using these sensors and it needs a good understanding of the technology to get a quality, noise free signal for accurate data.
-
Product
Signal Conditioning & Control
-
Offering a wide variety of products from amplifiers and comparators to redrivers, microcontrollers, data converters (ADC) and digital potentiometers (POTs).
-
Product
Accelerometers - Special Purpose
-
Analog Devices accelerometers and iSensor® MEMS accelerometer subsystems provide accurate detection while measuring acceleration, tilt, shock, and vibration in performance driven application. Our portfolio leads the industry in power, noise, bandwidth, and temperature specifications, and offers a range of MEMS sensor and signal conditioning integration on chip. Our MEMS-based Circuits from the Lab® reference designs have been built and tested by ADI experts to help you jumpstart your next system design.
-
Product
PCI-6255, 80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO PCI Multifunction I/O Device
779546-01
Multifunction I/O
80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO PCI Multifunction I/O Device - The PCI‑6255 offers analog I/O, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Rugged, Long Gauge Length Extensometers
Model 3543
-
Jinan Testing Equipment IE Corporation
With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
IOLITE LX
-
IOLITE LX - Embedded Data Acquisition SystemIOLITE LX is an embedded data acquisition system based on a low power Linux based ARM processor with open architecture being able to act like a data logger, real-time system, and signal conditioning frontend, all at the same time.
-
Product
Data Acquisition and General Purpose Test Equipment
-
All Fluke data acquisition products feature unique, built-in universal signal conditioning and a plug-in Universal Input Module to enable you to measure virtually any type of signal without having to purchase extra equipment. Plus, powerful, easy-to-use Windows®-based software supports easy configuration, advanced trend analysis, professional- quality reporting, and enables you to quickly build human-machine-interfaces without any programming.
-
Product
Signal Conditioners
-
Macom Technology Solutions Holdings Inc.
At MACOM we offer the industry’s largest portfolio of crosspoint switch devices with channel counts ranging from 2x2 all the way up to 288x288, and data rates from 3.2 Gbps to 28 Gbps. Our devices are equipped with signal conditioning technology that enables system designers to use lower cost board materials and components while increasing their system margin.
-
Product
PXI Analog Input Module
Analog Input Module
PXI Analog Input Modules feature multiple analog-to-digital converters (ADCs) as well as built-in signal conditioning. Sample rates range from 5 kS/s/ch to 2 MS/s/ch. You can choose from modules that offer up to 28 bits of resolution and up to 32 simultaneous channels. PXI Analog Input Modules offer different types of isolation and filtering, so you can choose options that meet specific application needs. The modules promote increased accuracy, high data throughput, and are ideal for scalable measurement systems with low and high channel counts.
-
Product
Fracture Mechanics Clip-On Gages
Model 3541
-
Jinan Testing Equipment IE Corporation
The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
PCI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.8 MS/s), 24 DIO PCI Multifunction I/O Device
779109-01
Multifunction I/O
The PCI‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Power Measurements Conditioner
-
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
Product
Multi-Channel Attenuation Control Unit (4-channels), DC to 6 GHz, 0 to 121 dB, 1 dB Step
J7204A
Attenuator
The J7204A is a multi-channel (4-channels) attenuation solution for signal attenuation and conditioning of up to 4 devices under test (DUT). Operating frequency from DC to 6 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7204A reduces cost of ownership and provide the best measurement accuracy.
-
Product
Cable Connectors & Adaptors
-
After many years supplying high qaulity signal conditioning instruments we understand the need to use high quality cable connectors & adaptors. The connectors used by Kemo on its cable assemblies are fitted by engineers with years of experience. This attention to detail ensures quality signal transmission and minmial noise within the signal path.
-
Product
Signal Conditioner
-
INELTA Sensorsysteme GmbH & Co. KG
Signal Conditioning of LVDT Displacement Sensors and Force Sensors
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784396-01
Sound and Vibration
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
High Speed Data Acquisition & Control Systems
Series 6700
-
Introducing the Pacific Instruments Series 6700 High Performance Signal Conditioning and Data Acquisition System, the premier Data Acquisition solution on the market. Based on the widely adopted Pacific Instruments Series 6000 system, the Series 6700 elevates performance and accuracy to levels not previously available.
-
Product
PXI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module
779629-01
Multifunction I/O
The PXI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
Strain/Bridge Input Module
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
PCI-6280 , 16 AI (18-Bit, 625 kS/s), 24 DIO PCI Multifunction I/O Device
779108-01
Multifunction I/O
16 AI (18-Bit, 625 kS/s), 24 DIO PCI Multifunction I/O Device - The PCI‑6280 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.