Product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
Analog Output Module
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-01
Sound and Vibration
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
R8rt
-
R8rtHigh-channel count DAQ system with high-end signal conditioning, powerful computer, SSD data logger, and low latency data output capability to 3rd party EtherCAT real-time controllers.
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-01
Sound and Vibration
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
Single Channel USB Programmable High-Pass Filter
USBPHP-S1
-
The USBPHP-S1 stand alone USB controllable module provides a single channel of high pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPHP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPHP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPHP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
Sound and Vibration
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781028-01
Strain/Bridge Input Module
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
Product
Signal Conditioning
-
Various preamplifiers and signal converters extend the range of applications for Elsys data acquisition systems.
-
Product
Modulation Distortion For E5081A Up To 20 GHz
S960704B
-
The Keysight S960704B modulation distortion software application enables fast and accurate active device modulation distortion characterization under modulated signal conditions up to 20 GHz. The wide dynamic range and vector error correction of the ENA-X yield an extremely low residual EVM of the test setup, delivering a complete picture of your device’s signal distortion performance without test system interference. S960704B software measures EVM, NPR, ACPR, and decomposes linear and nonlinear signals by spectrally correlating input and output spectrum without needing to demodulate. Integration with the ENA-X measurement flexibility enables quick modulated signal distortion measurements along with traditional VNA tests.
-
Product
Fracture Mechanics Clip-On Gages
Model 3541
-
Jinan Testing Equipment IE Corporation
The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
IOS Subsystems
-
Analog Devices has been the leader in isolated signal conditioning for more than 20 years. ADI IOS products feature complete modular solutions for industrial signal conditioning. These products are the benchmark for isolated signal conditioners, with price and performance unmatched in the industry.
-
Product
4-20mA Input A/D Converters
-
Analog Devices range of 4-20mA Input A/D Converters deliver accuracy, robustness and flexibility for Industrial Control applications. As the world’s leading supplier of data converters, Analog Devices is constantly introducing new A/D converters (ADCs) that drive system level architectures. Our portfolio of leading industrial 4-20mA Input A/D Converters offer considerable integration including, sense resistor, signal conditioning circuitry and advanced on-chip diagnostics to maximize performance and provide an integrated system level solution, all based upon robust silicon processes.
-
Product
Data Acquisition and General Purpose Test Equipment
-
All Fluke data acquisition products feature unique, built-in universal signal conditioning and a plug-in Universal Input Module to enable you to measure virtually any type of signal without having to purchase extra equipment. Plus, powerful, easy-to-use Windows®-based software supports easy configuration, advanced trend analysis, professional- quality reporting, and enables you to quickly build human-machine-interfaces without any programming.
-
Product
AFU 300 Auto Feather Unit
-
The Autofeather Unit (AFU), is mounted on the engine’s un-pressurized engine compartment, provides torque signal conditioning, automatic propeller feathering and remote engine uptrim command for Take-Off operations, as well as engine output torque indication to the aircraft cockpit during all engine operating conditions.
-
Product
SLSC Cards
-
SET offers a variety of different signal conditioning cards for connecting DUTs. The platform is designed to allow additional cards to be developed effectively in terms of cost and time.
-
Product
USB-6255, 80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device
779959-01
Multifunction I/O
80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6255 offers analog I/O, digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Multi-Channel Attenuation Control Unit (4-channels), DC to 6 GHz, 0 to 121 dB, 1 dB Step
J7204A
Attenuator
The J7204A is a multi-channel (4-channels) attenuation solution for signal attenuation and conditioning of up to 4 devices under test (DUT). Operating frequency from DC to 6 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7204A reduces cost of ownership and provide the best measurement accuracy.
-
Product
6 Channel Signal Conditioner & Data Acquisition Module
DP-cPCI-1197
-
DP-cPCI-1197 is a high-resolution signal-conditioning module that amplifies the signals from full-bridge based transducers. This signal-conditioning module is available on a cPCI module form factor. This module has four gain settings to accommodate a wide variety of sensor output voltages. In addition, this module has an adjustable excitation voltage to accommodate transducer excitation requirements.A high resolution sigma-delta ADC and variable gain amplifier forms the core of the signal conditioning system. Direct digital conversion and digital isolation ensures a better signal integrity in comparison with the conventional analog system.
-
Product
PCI-6284 , 32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device
779110-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device - The PCI‑6284 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Thermocouple Interface Amplifiers
-
Analog Devices offers specialized precision thermocouple interface amplifiers that provide a simple and effective solution for measuring thermocouple temperatures. With features such as integrated cold junction compensation and a high gain precision instrumentation amplifier, these thermocouple amplifiers provide a complete signal conditioning system in one IC package. ADI’s thermocouple amplifiers are suitable for use in diverse environments to measure a wide range of temperatures. These products will save you in cost, space, and unnecessary circuit design across a broad range of applications and industries.
-
Product
QuadPOD Conditioning Interface
JT 2147/VPC
-
The JT 2147/VPC is a variant of the JTAG Technologies QuadPOD signal conditioning interface specifically designed for use within Virginia Panel Corporation’s mass interconnect interface. The unit integrates both the JT 2148 transceiver circuitry, two independent, programmable TAP modules (of type JT 2149) and two TAP modules with I/O (of type JT 2149/MPV) on a single board that interfaces via the VPC QuadraPaddle connectors type G20x or G14x.
-
Product
Termination Cards
-
A signal conditioning board that provides eight independent SPDT relays, eight isolated outputs, and eight isolated inputs for applications requiring medium current capacity plus I/O isolation between an embedded computer and monitoring/control points.
-
Product
8AI Modbus RS-485 Remote I/O
ND-6117
Data Acquisition Module
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
Product
Data Acquisition Devices
-
Our data acquisition and encoding systems provide significant performance in reception, signal conditioning and encoding of all types of signals while used in missiles, airborne vehicles, mobile ground-based testing and other platforms that require ease of operation, flexibility, ruggedization and small packaging.
-
Product
USB-4431, 102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 4-Input/1-Output Sound and Vibration Device
780164-01
Sound and Vibration
The USB-4431 is designed for sound and vibration measurements. Input channels incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones. The four USB-4431 input channels simultaneously digitize input signals. The analog output (AO) channel is ideal for stimulus-response tests and can be synchronized to the AI channels.
-
Product
2- to 8-Channel Anti-Alias Low-Pass Filter and Instrumentation Amplifier Card
AAF-3PCI
-
The AAF-3PCI is a 2- to 8-channel anti-alias low-pass filter and instrumentation amplifier PCI bus plug-in board for front-end signal conditioning in PC-based data acquisition systems.
-
Product
High-Speed Digitizers / Oscilloscopes
Oscilloscope
GaGe high-performance digitizers are renowned for sustaining the maximum effective number of bits (ENOB) over a wide signal frequency range with quality signal conditioning and signal fidelity features. With A/D sampling rates up to 6 GS/s and very deep onboard acquisition memory of up to 16 GB, our high speed PCIe and PXIe digitizers provide optimal combinations of high sampling speeds with 8-bit, 12-bit, 14-bit, and 16-bit high resolution rates with large sampling memory options and high-speed data streaming capabilities.
-
Product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
-
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
Dual-Axis Accelerometer For HS5 & 6 Handyscopes, +/- 2G
TP-ACC20-09
-
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least +/- 2G.
-
Product
LVDT Sensor Amplifiers
-
Analog Devices signal conditioning ICs, together with linear variable differential transformers (LVDTs), can be used to convert mechanical position to a dc voltage. The IC provides both the excitation for the LVDT and the output conversion to dc level with a user selectable gain. ADI LVDT signal conditioners are available to interface with a wide range of LVDTs, including half bridge and standard 4- and 5-wire.