Product
Modbus RTU Analog Input
-
Provide direct connection to a wide variety of sensors to any host with an RS232 or RS485 port. The modules perform all signal conditioning, scaling, linearization, and A/D conversion. They each contain some discrete digital I/O lines and can measure signals such as:
-
Product
General Purpose Signal Conditioning Instrumentation
-
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements.
-
Product
Mass Flow Controllers for Gases
-
Sensirion''s mass flow controllers are characterized by fast and accurate control of gas flow over a wide dynamic range. Based on the innovative CMOSens Technology, the heart of these mass flow controllers is a calorimetric microsensor (MEMS), which is integrated with the complete signal conditioning electronics on one single chip. While the flow is measured using the thermal measurement principle, efficient control is provided by an analog controlling circuit. This unique integrated technological approach results in excellent performance and reliability - at a very attractive cost.
-
Product
Ruggedized Ethernet Data Acquisition Systems
Series 7000
-
The Series 7000 Ruggedized Ethernet DAS brings new capabilities and levels of performance to transducer data acquisition. The ruggedized system is designed for installation in wind tunnels, engine test stands and other facilities where it is desired to locate the DAS on or near the test article, reducing installation and cable costs while improving signal quality and reliability. Each unit is a network appliance which conditions, amplifies and digitizes outputs from transducers. Multiple units are easily combined and distributable for larger installations. Real-time temperature Compensation of gain offset and Excitation Voltage, quality signal conditioning with high gain and a 24-Bit A/D per channel provide a high accuracy and high resolution DAS that will perform across a wide operating range.
-
Product
Instrumentation Trainer
-
Strain Gauge Trainer provides study of Strain Gauge and their application for measurement of Strain. It helps to study bridge configuration of Strain Gauge and the signal conditioning circuits required to measure strain.
-
Product
15-CH Isolated Digital Output Module
ND-6056
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
Sound and Vibration
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
Single Channel USB Programmable Band-Pass Filter
USBPBP-S1
-
The USBPBP-S1 stand alone USB controllable module provides a single channel of high and low-pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPBP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPBP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPBP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.
-
Product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
Sound and Vibration
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
(ITA), Breakout Box & Fixtures
ITA
WinSoft provides a wide range of Interface Test Adapters (ITA) and test fixtures to meet the most challenging functional test and signal conditioning requirements. This includes high frequencies, voltages and current.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
Analog Output Module
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Signal Conditioning and Filtering
MSXB 065
-
The MSXB 065 Signal Conditioning Expansion Board provides filtered analog signal conditioning for voltage signals for Data Acquisition Processor systems. Each board has differential inputs; jumper-selectable simultaneous sampling; jumper-selectable gains of 1, 5, and 25; fourth-order anti-alias filters, cutoff frequencies from 100 Hz to 50 kHz.
-
Product
Bolt Extensometers for Proof Load Testing
Model 3565
-
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Remote I/O
-
ADLINK remote IO and serial communication cards are suitable for handling multiple digital signal types for IoT and other industrial applications such as facility monitoring, environmental monitoring, and industrial process control.Remote IO - NuDAM modules provide direct communication with various sensors, including performing signal conditioning, scaling, linearization and conversion to obtain temperature, pressure, flow, voltage, and current measurements. The new ND6100 series modules use Modbus/RTU remote data transmission protocols, providing customers with a comprehensive product portfolio. ADLINK's serial communication cards provide a PCI/PCIe interface and support RS-232 and CAN communication interfaces, allowing customers to choose the most suitable communication card for various automation equipment needs.
-
Product
Analog Input Modules
-
The modules provide direct connection to a wide variety of sensors and annunciators. They perform all signal conditioning and linearization and contain no pots or DIP switches. All user-selectable settings, such as ranges are stored in nonvolatile EEPROM, which maintains these values even after power is removed.
-
Product
Power Measurements Conditioner
-
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
Product
PCI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO (2.8 MS/s), 48 DIO PCI Multifunction I/O Device
779111-01
Multifunction I/O
32 AI (18-Bit, 625 kS/s), 4 AO (2.8 MS/s), 48 DIO PCI Multifunction I/O Device - The PCI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Dual-Axis Accelerometer For HS3/4/4-DIFF Handyscopes, +/- 5G
TP-ACC50-25
-
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least �+/- 5G.
-
Product
RF Microwave Switch Matrices
-
RF Microwave Switch Matrices provide automatic routing of RF microwave signals between test instrumentation and the unit under test (UUT). They provide consistent signal paths, enable automation of tests, and often include signal conditioning.
-
Product
PCI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO PCI Multifunction I/O Device
779068-01
Multifunction I/O
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO PCI Multifunction I/O Device - The PCI-6229 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
8-CH Analog Input Module
ND-6017
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
High Temperature Charge Mode Accelerometers
-
Charge mode output accelerometers from PCB® use piezo-ceramic sensing elements that output an electrostatic charge signal proportional to the applied acceleration. These sensors can operate at extremely high temperatures because they do not contain the built-in signal conditioning electronics that limit the temperature range of ICP® accelerometers. Charge mode sensors are used in the testing of gas and steam turbines, jet engines, high power motors, exhaust systems and automobile engines where temperatures can range from 500° F (260° C) to 1200° F (649° C).
-
Product
PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
781345-01
Strain/Bridge Input Module
102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
Product
RTM Analog Signal Conditioning Board
MS 3633I
-
CPCI Rear IO Analog Signal Conditioning Board is a signal conditioning and interface board for CPCI based Advanced Compute & IO Module (MS3639i). This board primarily focusing on all type of Analog input and output interface including signal conditioning from ACIO board to Rear IO interface. Board takes 16 Analog outputs and 64 Analog inputs from ACIO and does signal conditioning. In addition it shall generate additional 40 Analog input and 32 Analog output signals with signal conditioning and all IO interfaces are brought to two 96 Pin Euro Connector.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
Strain/Bridge Input Module
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
PXI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module
779629-01
Multifunction I/O
The PXI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Signal Conditioners
-
Macom Technology Solutions Holdings Inc.
At MACOM we offer the industry’s largest portfolio of crosspoint switch devices with channel counts ranging from 2x2 all the way up to 288x288, and data rates from 3.2 Gbps to 28 Gbps. Our devices are equipped with signal conditioning technology that enables system designers to use lower cost board materials and components while increasing their system margin.
-
Product
Trace Level Chemiluminescence NO-NOy Analyzer
Model T200U NOY
-
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
Product
PCI-6225, 80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device
779295-01
Multifunction I/O
80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device - The PCI‑6225 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Signal Conditioners
General Purpose
-
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.