High Frequency
High Frequency operating at 3–30 MHz.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
High Frequency Probe
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
High Frequency Synthesizer
HFS Series 1.25” x 1” x 0.25”
-
*Surface Mount Package *Broadband Designs Available *Optional Internal Reference *Optional Reference Detect Switch *Internal Reference Output Available *Off-the-Shelf Products Available
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
High-Frequency Ultrasonic Imaging System
USPC 3060 UHF
-
Ingenieurbüro Dr. Hillger Ultrasonic-Techniques
The ultrasonic imaging system USPC 3060 UHF is optimized for the testing wih high frequencies and delivers high resolution B-, C-, Dand F- scans. It consists of a scanning system with water tank and the external pulser-/receiver module as well as a 19”-rack with scanner controller and the ultrasonic system and monitor, keyboard and mouse.
-
Product
Short Pulse High-Frequency Laser Marker
LP-RV SERIES
-
Panasonic Industrial Devices Sales Company of America
The LP-RV Series FAYb Laser Marker features:- Short Pulse 20W Fiber Laser Offers Excellent Mark Contrast On Difficult To Mark Plastics And Various Other Materials- Optional EtherNET/IP Or ProfiNET Interface Adaptor Card- Modular Laser Oscillator System Makes Servicing In The Field Possible - Direct Connection To Panasonic PV230 Vision System For Mark Verification, Auto-Targeting, And Other Machine Vision Functions- Compact IP64-Rated Marking Head For Use In Harsh Environments- Compliant With FDA Regulations, GB Standard, KC Mark, Machinery Directive (Declaration of Incorporation), EMC Directive, RoHS Directive
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Digital Quad-channel High-frequency Lock-In Amplifier -
eLockIn 204
-
Digital quad-channel high-frequency Lock-In Amplifier.
-
Product
High Frequency Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
High Frequency LCR Meters up to 30MHz
11050
-
Chroma Systems Solutions, Inc.
The Chroma 11050 Series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range 75kHz~30MHz/1kHz~10 MHz/60Hz~5MHz suitable for analyzing component characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.
-
Product
8 Channel 1GHz High Frequency for SBDT Relay Module
DP-cPCI-4158
-
DP-cPCI-4158 is a 8 channel high frequency SPDT relay module. It provides for 1000V DC isolation between channels. This module is constructed using SPDT relays.
-
Product
High Frequency Coaxial Analytical Probes
-
D-COAX offers four analytical probe models: HyPac model for package characterization, and two models, Omni and OmniJet, for board level characterization, and DP1.4mm differential, single-ended probe.
-
Product
High Frequency (RF) Testing
-
C.C.P. Contact Probes Co., LTD.
CCP designs high frequency testing probes, coaxial probe sockets and pressurized conductive rubber sockets.
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
High Frequency Spark Tester
HF-15B
-
The HF-15B is a compact, digital 3kHz spark tester with a test voltage range of 500v to 15KV rms.
-
Product
Electronic Ballast High Frequency Parameters Tester
UI2002A
-
• Measure Vrms, Irms, W, PF/Hz • Voltage range: 10~600V, Current range: 10~2000mA, Frequency range: 20~70kHz • Accuracy: Class 2
-
Product
High-frequency Induction Heater Unit
-
High-frequency induction heater unit is a high frequency generator for non-contact heating of metal using electromagnetic induction.
-
Product
High-Frequency Generator
ZET 7191
-
The ZET 7191 is a high-frequency generator on the CAN bus intended for generating high-frequency signals of any shape. The shape of the generated signals may be of two types: sinusoidal and radio impulse.
-
Product
High Frequency Cartridge for HFP Series Probes
PACC-MS003
-
High Frequency Cartridge for HFP Series Probes
-
Product
High Frequency Electromagnetic Software
Sonnet Suites
-
The Sonnet® Suites™ develop precise RF models (S-, Y-, Z-parameters or extracted SPICE model) for planar circuits and antennas. The software requires a physical description of your circuit (arbitrary layout and material properties for metal and dielectrics), and employs a rigorous Method-of-Moments EM analysis based on Maxwell's equations that includes all parasitic, cross-coupling, enclosure and package resonance effects.
-
Product
High Frequency Insulation Tester
HFIT 8.0
-
The MEDTEQ HFIT 8.0 is intended for high frequency insulation testing against IEC 60601-2-2. This version includes in-built metering and automatic functions to make testing easy not only for design and laboratory testing, but also suitable for regular production testing.
-
Product
High-Frequency Test Coil
-
West Coast Custom Designs, LLC
is most commonly used by the neon industry for detecting leaks in a pumping system; the spark generated by the coil via the solid tip, will enter the tube through the leak and become bright white at the point at which it enters.
-
Product
High-Frequency Amplifiers
-
Tabor’s line of High-Frequency Amplifiers allows for a better, more advanced utilization of the already available digital outputs on some of Tabor’s arbitrary waveform generators.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58