Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
-
Product
Outdoor Permanent Mounted Load Bank
-
Mosebach Manufacturing Company
Mosebach Pad Mounted Load bank is designed to be permanently mounted next to a generator for dedicated testing. Its unique design allows it to be one of the smallest on the market! This size enclosure will fit 50 kW, 75 kW or 100kW of testing ability. Also available in 300kW and larger load banks.
-
Product
AC Load Banks
X60C Series
-
Mosebach Manufacturing Company
The X60C is a small suitcase style 60 kW load bank.
-
Product
AC Load Bank (Resistive/Reactive)
K-1000 Resistive/Reactive
-
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
Product
Load Banks
-
From battery discharge testing to power equipment verification, our load banks are designed for precise testing and maintenance, helping you maintain peak performance and compliance with ease.
-
Product
Resistive AC Load Bank
-
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
Product
Battery Data Logger
BDL-3926C
-
Kongter Test & Measurement Co., Limited
BDL-3926C Battery Data Logger is wireless monitoring device for string voltage, cell voltage, current and temperature. It works individually to reflect battery status or co-works with Kongter’s other battery test equipments like battery charger and K-3980 DC load bank. For different battery systems, it has customized configuration from 12V to 480V or upper. And it has easy expansion for all battery systems.
-
Product
Load Banks
EL Series
-
*12kW, 15kW and 18kW DC Electronic Load*All of our Load Banks are continuously rated for Power and Current.
-
Product
Anti-Islanding Load Banks
AI-Series
-
AI-series anti-islanding load banks containing purely resistive, inductive, or capacitive load, have segmented combination control of power input, and can simulate a variety kinds of power loads to meet the grid-connected inverter full load test requirements.
-
Product
AC Load Bank
-
PC software controls offer advanced load profile solutions and model options range from small, portable, low-power units, to high-power indoor or outdoor permanent load solutions.
-
Product
Resistive Load Banks
R Series
-
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
Product
Variable Resistor Load Bank
REOLOAD 100
-
A variable resistor load-bank with fixed stages connected in parallel and switched in, as required, with an adjustable stage for fine trimming. Designed for testing equipment under load. 1000V (AC or DC). 250A and 2500
-
Product
AC Loads
-
During AC electronic load tests, loads are simulated to confirm that a power device or system can operate properly, according to its capacity rating. This type of resistive load testing can often pinpoint power system issues in time for preventive maintenance to be performed. AC load tests can also evaluate the capacity of your essential batteries. Our loads are built to help you reduce downtime, power disruptions and risks to systems. They are valued in utility, transportation, data center, industrial manufacturing and communications environments. Our portable AC load products from Eagle Eye Power Solutions withstands harsh field testing conditions. The AC Load Banks from Eagle Eye are designed to test generator sets, UPS units, power inverters and other AC sources of power. Transcat also stocks devices that flexibly support both AC and DC load applications.
-
Product
Battery Load Bank
-
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
Product
Battery Load Bank
K-3980
-
Kongter Test & Measurement Co., Limited
Kongter offers a series of customized DC load banks with many different models for constant current battery discharge test and battery capacity test. They cover a wide voltage range from 12V to 480V nominal voltages with current up to 600A. They are widely applied in various industries. With its optional battery Data Acquisition Case (DAC), discharge values of EACH cell could be monitored in battery load bank and PC software simultaneously by using Kongter’s data view software.
-
Product
Amplifier Dyno
AD-1
-
The AD-1 Amplifier Dyno is a tool that is designed to be used any place an amplifier exists. It can be used in a lab or production line to test true amplifier power output, quickly and easily. It is simple menu driven, does not require a computer, and cannot be cheated as the load banks are internal. It can be used in an automotive audio install shop to test true amplifier output while the amplifier is installed in the customer's vehicle.
-
Product
Battery Test & Management
-
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of products for testing and measurement of battery from your critical power systems. It includes battery online monitoring system, battery tester for internal resistance/conductance, battery charger, battery load bank, battery data logger, battery charger/discharger and so on.
-
Product
Resistive & Capacitive, Inductive AC Load Bank
RLC
-
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
Product
Load Bank
RLB
-
RARA manufactures load banks, ranging from small portable units for testing generators to multi-megawatt designs for larger applications. Regular load testing, along with correct battery maintenance, is the best way of ensuring the reliability of standby power systems. It is routine for all newly-installed generating sets to have a load test during the commissioning process in order to prove the performance of the set and all ancillaries-cooling system, exhaust system, switchgear and protection schemes.
-
Product
Three Phase Load Bank
REOLOAD 310
-
A three phase load bank rated for 48kW, with fan cooling. The front panel layout includes a switch panel for configuring the separate resistor modules to give the required resistance and current range. There are also digital panel meters for displaying the phase voltages and currents. An interface for PLC control is also provided.
-
Product
Load Banks
PARELO
-
Amfax introduce the latest generation of load banks we affectionately call PARELO. This range of load banks provides a combination of high performance passive resistive loads along with extreme flexibility of use. This is achieved by our unique FLEXI-phase Switching(TM) technology.. Designed primarily for offering high wattage loads for the aerospace, energy, automotive and transport sectors. PARELO load banks are a cost effective solution for companies requiring high wattage loads when testing their products.
-
Product
Locomotive Testing
DC7000
-
A purpose-built load bank for the performance testing of engines and generators of all types of diesel electric locomotive up to 4000hp rating, with easy-to-use resistance adjustments allowing tests to be carried out over the whole power envelope. Capacity 0 7000A continuously at up to 2000V DC
-
Product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
-
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
Product
Rack Mounted Load Banks
-
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
Product
Battery Monitoring System
BMS-3923
-
Kongter Test & Measurement Co., Limited
This battery monitoring system is an innovative solution to measure battery condition with communication way of Power Line Carrier (PLC). With multi-frequency measurement, users can monitor and analyze battery in all aspects: internal resistance, voltage, current, capacitance, temperature and so on.Based on our years experience for battery management system, we build very mature mathematical model that precisely predicts battery capacity. This will in another hand reduce the time that we spend on capacity measurement using a battery load bank.
-
Product
Multi-Unit Controllers
-
Mosebach Manufacturing Company
Mosebach’s Multi-Unit Controllers are built to help you manage your load banks in operation – whether 10, 20 or 500 units ganged together.
-
Product
AC Load Banks
X100L-600 Series
-
Mosebach Manufacturing Company
Mosebach’s X100L-600 is the smallest load bank of 100 kW with 5 kW resolution. Offers a continuous load at 600/480/240/208 volts. Great for most generator testing. And lightweight – only 64 lbs!
-
Product
AC Load Banks
K-1000 Series
-
Kongter Test & Measurement Co., Limited
Load bank testing is vital to replicate and verify the operation of critical backup power systems such as diesel generators and uninterruptible power supplies (UPS). Kongter offers a wide range of customer-tailored AC load banks that excel in a range of load test applications and environments.
-
Product
Load Banks
-
Power House Manufacturing, Inc.
Load banks manufactured by Power House are engineered to be smaller and lighter than the competition.
-
Product
12V 30A Battery Load Bank/Battery Discharge Tester
FST-DC12V-30A
-
Foresight Electronics Co., Ltd.
Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others Discharge parameters can be monitored in real-time during the capacity test.
-
Product
ESS Performance Test System
Test System
The Energy Storage System (ESS) Performance Test System is used to evaluate, test, and certify the performance of energy storage systems up to 2MW. The system is a configurable platform with over 200 channels of simultaneously measured AC and DC voltages and currents, environmental temperatures, airflow, and communications. Intuitive software provides real-time monitoring and analysis of power, energy and efficiency to adhere with industry standards. The test system interfaces hardware such as load banks, and controls the ESS to simulate utility applications such as peak shaving and frequency regulation.