Reflection
-
Product
Reflection/Transmission Test Chamber
CHTR-100
-
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.
-
Product
Integrating Spheres For Reflection, Transmission, Absorption
-
Universal integrating spheres and accessories optimized for the measurement of reflection, transmission, absorption and photoluminescence
-
Product
Transmission / Reflection Measurement
-
Measure spectral transmittance and reflectance of optical elements such as lens, plate glass, filter, reflector, prism and so on.The wavelength range is 350 to 1100 nm as standard and 220 to 2000 nm as an option.Reflection measurement of a general spectrophotometer can only measure several types of fixed angles, but in this device the incident angle of the sample at the time of reflectance measurement is variable at an arbitrary angle and the minimum incident angle at reflectance measurement is 15 ° ( Optical axis angle 30 °) can be set up.
-
Product
Reflection Meter
RC-088
-
This instrument is a special equipment for measuring the reflectivity of rearview mirror (or similar product) of motor vehicle. The product composes intelligent measuring instruments, optical integrating sphere, parallel lamp, standard light source, constant current source etc. It is easy to operate,it can measure the reflectivity quickly and accurately. On instrument structure, it adopts standardized modulation design. It takes latest single chip as its digital central processing element. After the measuring signal is converted by modulus, CPU will do some computation and compensation. The instrument can display the reflectivity of device which is measured in rear time. It operates simply and quickly, the indication is direct and accurate. It’s good for quality examination &control in the production scene as well as laboratories. This product has the convenience &quick demarcation way, can meet requirement of different occasion. It is applicable for measuring light reflection on mirror and not mirror parts.
-
Product
Reflection Probes
-
Reflection probes are used to obtain spectral information of diffuse or specular materials. The light from a light source is sent through six illumination fibers to the sample, and the reflection is measured by a 7th fiber in the center of the reflection probe tip. Discover our reflection probes below.
-
Product
PXI-2797, 40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module
782357-01
RF Multiplexer
40 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2797 offers a high-density, terminated multiplexer with dual 6x1 multiplexer banks in the same module. The internal termination of the PXI‑2797 helps prevent high-power reflections that arise from open channels on the module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.
-
Product
Managed Hub
HUB-5595
-
The HUB-5595 is a managed hub designed to operate with the Abaco Systems 5565 family of Reflective Memory real-time network products. The Reflective Memory hub can automatically bypass ports when it detects a loss of signal or the loss of valid synchronization patterns, allowing the other nodes in the network to remain operational.
-
Product
15% Beam Splitter
10725C
-
The 10725C 15% beam splitter, designed for beam diameters of 9 mm or less, reflects 15% of the total incoming laser beam and transmits 85% straight through. This optic is without housing and requires a user-supplied mount.
-
Product
Halogen & Deuterium Halogen Light Sources
-
Avantes Deuterium light sources are known for their stable output ad are used for UV absorption or reflection measurements. These can also be used as irradiance calibration sources due to their high stability. The standard AvaLight-DH-S mixes the halogen light with the Deuterium light, thus producing a wide spectral range light source. The output spectrum of Deuterium light sources exhibits several peaks, with a prominent peak at 656 nm. The AvaLight-DH-S-BAL incorporates a dichroic beam splitter installed to minimize these peaks, providing a smooth spectrum from 200-2500 nm.
-
Product
Power Supplies
CU-400B
-
The CU-series is a semi-modular power supply that lets you select the cables you need while powering your system at a healthy voltage. Everyone likes a clean and easy installation. This power supply allows you to keep what you want and remove what you don't. While necessary connectors, like the 20+4 pin power connector, are attached to the unit, you decide which of the others should stay. Customize your power supply to reflect your system.
-
Product
Near-Field Detection Module for Imaging
Reflection
-
Reflective AFM-tip illuminationDetection optimized for high-performance near-field imagingEnables optical amplitude and phase resolved near field measurementsNear-field spectroscopy possible via sequential imaging (Requires tunable illumination unit)Patented background-free detection technologySuited for visible & infrared wavelength range (0.5 20 m)Version for infrared & THz wavelength range (5 300 m) availableSupported AFM scan-speed: up to 20 m/s @ highest spatial resolution
-
Product
1.8 - 525 MHz GrandMaster SWR Meter
MFJ-874
-
MFJ Grandmaster SWR/Power meters are the Cadillacs of ham radio! All GrandMaster feature peak and average, forward and reflected power readings and have selectable power ranges. Covers HF /UHF / VHF. 30, 300, 3000 Watt power ranges.
-
Product
DOI / Haze Meter
807
-
TRICOR’s Hazer Meter and DOI is ideally suited for measuring flat, non-textured high reflectance surfaces. The Model 807A Haze Meter design is in accordance with ASTM E430 and ASTM D5767 (method A) and is used to measure ±3 degrees around the specular lobe centered at 30 degrees in approximately 220 increments. That’s an angular sample size of 1 sample per 1.6 minutes of arc! This allows differentiation between samples with very small differences in reflectance characteristics. Verified replacement for the older Hunter Dorigon II haze meter unit.
-
Product
Versatile RF Network Analyzers for LF and MF
TE3000-series
-
The TE3000-series of RF vector network analyzers have full vector measurement capability, and accurately resolves the resistive, capacitive and inductive components of a load. The user can display the vector impedance plus a range of related parameters including SWR, reflection coefficient, return loss and R-L-C equivalent circuit.
-
Product
Power Cable Fault Locator
TM500
-
TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.
-
Product
Loaded Spectrophotometer
DSCD-900
-
DSCD-900 is a highly performance spectrophotometer with test caliber upward. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula. It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers’ measurement requirement.
-
Product
SP2T RF Pin Diode Switches To 18 GHz
-
Pulsar Microwave's 2-way switches are available in absorptive and reflective designs from 20 MHz to 18 GHz. They are also referred to as single pole, double throw and abbreviated SPDT or SP2T. These switches have a typical VSWR performance of 1.6:1 or better and input power handling of 200 milliwatts maximum. Switching time is 100 nanoseconds, and isolation of 60 dB or greater for most models. Supply voltages are +5V and -5V, with TTL logic control voltage of 0 to 5 volts.Both absorptive and reflective SPDT switches are packaged into Pulsar Microwave's SW2 outline. Configuration is standard with SMA female connectors. Voltage is applied with wire wrap feed thru terminals. The housing serves as electrical ground, and two turret terminals are installed for wiring.
-
Product
DCDC
DPS/DPD Series
-
The DPS/DPD is an economically priced series of miniature DC/DC converters offering both single and dual outputs. These unregulated converters offer the latest in MOSFET technology. Featuring efficiencies to 80% and a calculated MTBF in excess of 1,000,000 hours. Additional features include an operating temperature range of -25°C to +71°C with no derating and a LC input filter to reduce the reflected ripple. All this in a package measuring 1.1” x 1.1” x 0.5” high make these converters ideally suited for 0.75” cardspacing.
-
Product
Antenna Impedance Analyzer
TZ-900 AntennaSmith
-
Analysis Parameters: SWR, Complex Impedance, R+jX, reflection coefficient, Smith Chart. 0.2 - 55 MHz • SWR
-
Product
Standard IR Target Projectors
-
Santa Barbara Infrared’s 14000Zi Series reflective infrared target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies and 300 Series Target Wheels. SBIR also offers a standard athermal target projector with a 5.7° field of view (FOV).
-
Product
Laser Tachometer
LT-880
-
The LT-880 Laser Tachometer is a non-contact instrument designed to sense the presence or absence of a reflective surface in its optical beam. A TTL signal is asserted whenever a reflective surface is placed within its field of view. The signal may be used with a counter or spectrum analyser to sense linear translation, rpm or transient vibrations.
-
Product
Transition Time Converter, 150ps
15435A
-
The new design of these transition time converters ensures very low signal reflection far beyond the 3 dB point, unlike conventional converters.Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications.The converters are fitted with SMA connectors, one male, one female.
-
Product
2x2 Interferometric Couplers
-
Feasa manufactures a series of couplers, which are optimised for use in fiber interferometers. The couplers have a highly reflective end on one or more output ports and can be configures as 1x2 or 2x2.
-
Product
Fixed Laser Source Module
Laser Source
Keysight offers a broad choice of fixed laser sources, which are available as single-wavelength and dual-wavelength modules as part of the Keysight Lightwave Solution Platform. The Keysight 8165xA Fabry-Perot laser sources can be used in conjunction with optical power meter modules for insertion loss, optical return loss and PDL measurement of broadband components and fiber. The Keysight 81663A Distributed Feedback Laser Sources are best suited for amplifier test and WDM system test applications. Keysight covers PON and common WDM wavelengths with its 81663A Distributed Feedback (DFB) laser source modules. The precise tunability around ITU-grid center wavelength gives you the flexibility to match test setups to the latest requirements of the DWDM-system. The fine-tuning allows to shift the center wavelength from one DWDM transmission channel to the adjacent channel in dense WDM systems. The built-in isolator ensures highest laser stability, even when reflections are present in the optical path.
-
Product
Dual-Directional Couplers
-
KRYTAR’s directional couplers are uniquely designed for systems applications where external leveling, precise monitoring, signal mixing or swept transmission and reflection measurements are required. These couplers provide simple solutions for many applications including electronic warfare (EW), commercial wireless, SATCOM, radar, signal monitoring and measurement, antenna beam forming, and EMC testing environments. For many space-restricted applications the compact size makes KRYTAR directional couplers ideal solutions.
-
Product
Spectrally Flat Class C Albedometer
LPPYRA06
-
Albedometers are composed of two pyranometers that are mounted back-to-back. An albedometer measures in two directions; one pyranometer is facing upwards (measuring the global solar radiation), the other pyranometer is facing downwards (measuring the reflected solar radiation).
-
Product
Near Field Probes
-
Anteral has extensive background in the design of Near Field Probes (open ended waveguides probes). Our Near Field Probes are currently being used in several laboratories around the world including the ESA's anechoic chamber. Anteral designs Near Field Probes from 10 GHz to 750 GHz covering the sectors requirements. Moreover, our Near Field Probes have a sharped design minimize reflections.
-
Product
Integrating Spheres
-
Integrating spheres are used especially for measuring divergent light sources such as LEDs. The light is introduced through the input port, then reflected many times by the highly reflective interior of the sphere until it illuminates the inner surface uniformly. A detector samples a small fraction of this light to measure the total power input. Ophir integrating spheres have a highly reflective diffuse white coating for measurements independent of beam size, position and divergence. There are several sphere sizes, apertures and wavelength regions available. The large IS6 series has 2 configurations for measuring divergent or parallel beams.
-
Product
SPECTRA ONE DEGREE PHOTOSPOT
-
The Spectra One degree Photospot is a unique optical accessory that converts your Spectra Professional IV-A into a high-sensitivity one degree Spotmeter for narrow-angle reflected-light measurements. Readings are displayed in reflected f/stop or in footlamberts in luminance mode