Transfer Standards
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25Z-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-010-003
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1V-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Gas Flow Standards
-
Fluke Calibration offers molbloc/molbox gas flow calibration systems to calibrate flow meters and controllers over a very wide range of flows. The systems are fast, precise and transportable and can be fully automated using COMPASS for Flow software. molblocs, which are the heart of the measurement system, are mechanically stable, gravimetrically calibrated laminar flow and sonic nozzle elements.
-
Product
GPS Frequency Standards
-
Precision Test Systems manufacturers' a full range of GPS and GNSS frequency standards that are disciplined to most of the worlds satellite systems.
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
42-782B-541-E
-
The 40-782B-541-E (PXI) and 42-782B-541-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-215-013
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard Helmholtz Coils
-
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
-
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Turbidity And Standard Meters
-
Accurately measure the cloudiness of a fluid caused by suspended particles with turbidity meters and standards from HF scientific. Our turbidity meters and standards instruments include features that simplify installation, maintenance, and data access.We offer reliable turbidity meters including an online turbidity meter, handheld turbidity meter, and benchtop turbidity meter.
-
Product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
-
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5E
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-410-005
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard Voltage 50 Pin D-Type Connector Blocks and Breakouts for Pickering
-
The connector blocks and breakouts below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Calibrated Diffuse Reflectance Standards
-
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T38-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Inductance Standard
1482 Series
-
The GenRad 1482 Standard Inductors are the standard of choice in metrology labs. Used today by national metrology institutes and primary standards bodies around the world, these inductors have no peer or equivlent.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-415-016
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Capacitance Standard Set, 0.01uF To 10uF
16380C
-
The 16380C is a standard capacitor set consisting of three precision capacitors - 0.01uF (16385A), 0.1uF (16386A), 1uF (16387A),and an optional 10uF (16388A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-310-009
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
-
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-F
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-410-006
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.





























