Transfer Standards
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1B-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2L
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-4
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Coaxial Transfer Switch, DC to 26.5 GHz
87222C
Coaxial Switch
Flexibility is essential in signal routing applications, and the Keysight 87222C 4-port coaxial transfer switch offers just that. It provides exceptional repeatability, low insertion loss, and high isolation. These switches provide simplification of design in signal routing and conditioning applications. The Keysight 87222C can be used in a variety of applications such as, a drop-out switch, switching two inputs and two outputs, or signal reversal switching.
-
Product
Standard Loggers
-
Our standard loggers can measure up to 13 parameters. Numerous configuration options allow for maximum customization for your measurement needs. In addition to our conductivity, temperature and depth sensors, many others, including third-party sensors, can be used with our recorders. Measure salinity. Measure tide and waves. Altitude & Attitude Logger.
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5H
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Frequency Standards
-
Precision Test manufacturers a complete range of frequency standards. This includes rubidium and OXCO models either free running or controlled by an external reference (GPS, GLONASS, Galileo, 1pps, 5 MHz, 10 MHz, IRIG-B etc). Output frequencies typically 1 MHz, 5 MHz, 10 MHz, 10.23 MHz, 13 MHz, 100 MHz or bespoke frequency.
-
Product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
Product
Standard Clamp Meters
-
For extreme temperatures, choose an analog clamp meter that can measure amps and volts without needing batteries.
-
Product
Innovative Open Standard
PROFINET
-
PROFINET is the innovative open standard for Industrial Ethernet, development by Siemens and the Profibus User Organization (PNO). With PROFINET, solutions can be implemented for factory and process automation, for safety applications, and for the entire range of drive technology right up to clock-synchronized motion control. PROFINET is standardized in IEC 61158 and IEC 61784. Profinet products are certified by the PNO user organization, guaranteeing worldwide compatibility.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Super MUTT Deluxe Standard Edition
#9008-SE
-
Innovative Products of America
The Super MUTT places a load on the trailer's electrical circuits to identify wiring problems while providing remote control operation over both air brakes and lights. Built to facilitate a one-man testing operation, the Super MUTT reduces guesswork and inspection time to prevent failures that lead to expensive road calls and citations. The remote control allows for repetitive air brake actuation at each axle to reveal developing problems often missed by normal testing procedures.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-415-014
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Connector for Pickering
-
The connector to connector cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
Product
Standard Helmholtz Coils
-
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Electron Multiplication (EM) Standard Image Sensors
-
EM (Electron Multiplication) is a technology that uses on-chip gain in the charge domain to effectively eliminate read noise from an image sensor. This enables advanced ultra-low light applications that require extreme sensitivity at fast frame rates. Examples include life science applications such as single molecule detection, super resolution microscopy and spinning disk confocal microscopy along with physical science applications such as nanotechnology imaging, Bose Einstein condensates and soft X-ray spectroscopy, and astronomy applications such as adaptive optics and lucky imaging. The inclusion of an additional conventional output allows further flexibility for applications such as true 24 hour surveillance.
-
Product
15T Standard Running Line Monitor
RLM15T-3.0-S
-
The DLM 15T Running Line Monitor measures the tension on a rope passing through its three wheels. Typically used in cable laying and winch operations to measure and record line tension the robust design has become an industry standard. The monitor can be supplied as a separate item for integration with customers existing PLC’s or with a DLM digital display/HMI touch screen display.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-210-001
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-410-012
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Automatic Voltage Regulating Relay- Standard Model
-
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-J100-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Low PIM Coaxial Switch, DC to 26.5 GHz, Transfer
87222R
Coaxial Switch
Low passive intermodulation (PIM) is crucial for applications where two or more transmitted signals share a common antenna or whenever the transmitter signal is too high or the receiver is sensitive to high intermodulation. The Keysight 87222R is a low PIM transfer coaxial switch, operating from DC to 26.5 GHz, which can help to keep the system PIM level low. A guaranteed 0.03 dB insertion loss repeatability and 3 million cycles of operating life ensures signal integrity, improves testing efficiency, and ultimately maximizes test throughput.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58