Standard Transformers
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25C-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
-
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
Transformer Winding Resistance Tester
KRI 9310
-
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
Product
Split type AC Current Transformer
CTS-100
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy installation by metal fitting.
-
Product
Variable Transformer DC Power Supplies
-
Variable DC power supplies are AC to DC power supplies with a variable DC output. The output can be varied with a Variable Transformer (also known as variac). The Variable Transformer can be adjusted manually or with a motorized control. The AC input power can be single phase or three phases. With single phase AC input, the DC output ripple is very high (50%). With three phase AC input, the DC output ripple is low (5%). This would be a key benefit for selecting three phase AC input instead of single phase.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Voltage Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Are a parallel-connected type of instrument transformer. They are designed to present a negligible load to the supply being measured and have an accurate voltage ratio and phase relationship to enable accurate secondary connected metering.
-
Product
Current Transformer Test Set
-
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T80
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 3.00 (85.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
G-S-F
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Test Sets For Transformer Industries
-
Contemporary Test Sets For Transformer Industries are developed to recognize the potentially disastrous current transformer errors. They prevent the primary current from overpowering insulation and short circuits. They are used for developing a testing and maintenance plan for addressing the errors before any failure to save money and time. With these powerful test sets, they are sure to perform saturation testing to test the knee point of a signal by comparing primary and secondary windings.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-J100-1
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50B
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
Product
Electrical Standards
-
To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.
-
Product
Nanoscale Microscopy Standards
-
The nanoscale AFM-CD standard (CD, critical dimension) contains structures to calibrate line widths and periods of AFM (atomic force microscopy) devices.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4E
-
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard Gain Horns
-
26 dB typical gain at center frequency. Aluminium made High performance Standard Gain Horn. From 75 GHz up to 500 GHzUG-387 U/M flange. Specific gain values can be requested. We offer two Standard Gain Horn product lines that go from 75 GHz up to 500 GHz, one with high performances for the most demanding of lab applications and the other with reduced prices and sufficient quality for the majority of SGH applications. Anteral makes sure that each client can have the best SGH for their particular needs.
-
Product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
-
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25V-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Cup Reduced Concave, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0G12
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Series Standard HV Capacitors
PMT10000
-
Power Measurement Technologies Inc.
High voltage, low dissipation factor, gas-filled Standard Capacitors for indoor use in a laboratory or production environment. A three terminal design configuration allows accurate measurements of capacitance and dissipation factor (tangent delta) with little or no effect from test lead or stray capacitance.
-
Product
Standard CW Amplifiers
-
The BT-AlphaA-CW series is a range of classAB RF power amplifiers covering the 10kHz to1MHz frequency range. Rugged, solid-state design - high reliability. Extremely high phase and amplitude stability. High linearity. In-Built Protection. Very fast blanking. Capable of pulsed operation. Competitively priced. Suitable for CW radar, communications, HF/VHF jamming, particle accelerator applications/plasma systems, plasma, RF heating and other scientific applications.
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard Electromagnetic Vibrator
KD-9363-EM
-
King Design Industrial Co., Ltd.
The purpose of vibration testing is to make a series of controllable vibration simulation in lab, no matter generated by natural or man-made vibration environment; such as waves, tidal flaps, wind, earthquake or rain and so on. It is to test if the product is capable of sustaining the vibration environment exerted from transporting or usage along its effective life cycle; and certify the standard of design & functional requirement of product. The value of vibration testing is to confirm the reliability of products and effectively screen out the bad products in factory; avoiding damages occurred at arrival; and to assess the failure analysis on the non-performing products; expecting to reach a high standard, high-reliability products. The vibration test stresses on the continuity and fatigue; and contributes to the understanding of product’s status under vibration circumstance in a normal environment; and avoids the product’s unpredictable damage caused under certain vibrating frequency for a long time.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.