Standard Transformers
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-2V1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Reflectance Standards
-
Diffuse reflectance calibration standards in white or different grey levels. Traceable calibration for the wavelength range from 250 nm to 2450 nm.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
-
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
Industry Standard in Noise Measurement
PN9000
-
The PN9000 is a simple and fast Automatic Phase Noise Test System covering a very wide frequency range(2 MHz to 140 GHz). Its modular architecture allows optimum configuration, multiple measurement techniques and future growth in a compact instrument.
-
Product
Viscosity Standards
-
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
Product
Harmonic Mitigation Transformer
-
A specialized three-phase transformer designed to reduce harmonic distortion and voltage distortion caused by non-linear loads (e.g., computers, VFDs) in electrical distribution systems.
-
Product
Transformer Oil Dielectric Strength Testing
LS -JJ-II
-
Chongqing Lushun Scientific & Technological Development Co., Ltd.
1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.
-
Product
Ultra Low Noise, Rubidium Frequency Standard.
A10-M
-
Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.
-
Product
Instrument Transformer Testing
-
Weshine Electric Manufacturing Co., Ltd
Your product description goes here.
-
Product
Qseven® Standard Size Module with Intel Atom® E3900, Pentium® N4200 and Celeron® N3350 Processor (codename: Apollo Lake)
Q7-AL
-
The Q7-AL Computer-On-Module (COM) combines the QSeven® 2.1 standard with the Intel (“Apollo Lake”) Atom® E-series and Pentium® and Celeron® N-series System-on-Chips (SoCs), providing ideal solutions for low power consumption and high pin/area density requirements. The module provides the high integration, high performance, low power, and ruggedness favored by Internet-of-Things (IoT) applications such as retail transactional clients, digital signage, and in-vehicle infotainment systems.
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1C1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Incremental > Standard Encoders - Hollow Shaft
-
Incremental > Standard Encoders - Hollow Shaft
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-9
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-H200-1
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
Standard CT
2000A
-
• High accuracy of 2000/5A (0.05%) • multiple ratios • Various Current ratings
-
Product
Rectifier Transformers
-
Osborne’s Rectifier Transformers are used in conjunction with various rectification configurations to convert AC input to DC output(s). Key characteristics include regulation, transformer utilization and AC ripple. Osborne rectifier transformer designs are often engineered to operate in advanced rectifier circuit applications.
-
Product
Standard for Mass Interconnect Performance
TITAN
-
TITAN sets the standard for Mass Interconnect performance, configuration modularity and long term reliability. TITAN has been designed to offer exceptional configuration flexibility for use with any ATE platform and offers unparalleled I/O density coupled with the widest selection of contact types available for Mass Interconnect.
-
Product
Standard Type Spring Probes
-
From for bare board to for ICT, we have variety of spring probes for PCB. In addition to variety of tip type and total length, we also have receptacles that match the best to spring probes. We can also attach lead wire to the receptacles.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72J-4
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-C
-
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1B
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
800MM 31.5In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles IP54 Standards
DL411
-
Advance Plus Trading Co., Ltd.
Model Number: DL411 Key Specifications/Special Features: 800MM 31.5INCH Digital Level with level bubbles, 2 hand shanks, LCD bright backlight display, IP54 standards 1. 800mm 31.5inch level with 2 bubbles, 800*28*64mm(L*W*H), net weight: 700g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. 2pcs Handshanks design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Transformer Performance Tester
6691
-
applying ±90V voltage on the winding of the transformer demagnetized and get the voltage value on the terminal and the current value in the winding to draw the hysteresis characteristic curve. This method can be used for linear quantitative analysis of residual magnetism in transformers, and fast demagnetization can be achieved by tracking hysteresis curves. The analyzer can measure magnetism residual rate before and after demagnetization.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1Q1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Flat, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0F
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Fully Automatic Transformer Winding Resistance Tester
-
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
Product
Instrument Transformer
-
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.
-
Product
Transformer & Capacitor Testers
-
*Quick and easy check for opens or shorts on transformers before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers*Tests the primary and secondary sides of de‑energized transformers without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer*Automatic self-test feature*Magnet holds the tester in place while testing