References
A source of comparison.
See Also: Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transformers, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
8-Channel VME Strain Gauge/Weighing Module
V380
-
The V380 is a VME/VXI compatible eight-channel strain-gauge signal conditioner which is optimized for load-cell weighing applications. The module includes tare (zero reference), DSP-based high-order filtering, averaging, triggered weighing, and other functions not commonly available in conventional strain-gauge signal conditioners.
-
Product
0.75" Synthesizer
LX Series 0.75” x 0.75” x 0.15"
-
*Surface Mount Miniature Package *Optional Internal Reference *Output Power to +10 dBm Available
-
Product
SMA Male to SMA Male Cable, 50 Ohm, 1 m
781845-01
Coax Patchcord
The SMA-SMA Coaxial Cable, sometimes referred to as SMA100, connects measurement and signal devices. NI offers this 50 Ω cable in different lengths, this one is 1m.
-
Product
X13 GPIB Cable, MicroD25 to Shielded cable/Standard connector, 2M
183285-02
GPIB Cable
24-Pin Male/Female GPIB to 25-Pin Male Micro D-SUB GPIB Cable - The 24M-24F-MicroDB25M X13 GPIB Cable, sometimes referred to as the X13 cable, connects your system to GPIB devices or interfaces for instrument control. This standard shielded cable can connect PXI Controllers to instrument control devices and is offered in different lengths.
-
Product
Scanning Droplet Cell
VS-SDC
-
Scanning Droplet System (SDC) uses a compact peristaltic pump to force electrolyte through a small diameter tube and into a specifically designed head. This PTFE-based SDC head is machined to allow electrolyte to flow past an installed Reference Electrode and then to a port at the base of the head.
-
Product
FMC Module
FMC1831
-
Sundance Multiprocessor Technology Ltd.
The FMC1831 is an FMC module designed to be compatible with AMC, VPX, PCI, PCIe, CompactPCI and PC/104 carriers. The module has two dual channel AD9361 transceivers with a maximum sampling frequency of 122.8 MHz over a bandwidth of 200 KHz to 56 MHz. A reference clock can be either externally supplied or be generated from an internal PLL. All input and output signals are connected via SSMC connectors for secure connectivity and signal integrity.
-
Product
Personal Gamma Radiation Dosimeter
EcotestCARD
-
The radiation monitoring badge EcotestCARD allows storing dose accumulation history with real time reference in the non-volatile memory, and communicating it to the computer. If the programmed threshold levels of gamma dose or its rate are exceeded, light and audio alarms are actuated.
-
Product
Handheld RF Spectrum Analyzer With 1MHz To 1.3 Or 2.7GHz Bandwidth Options
PSA Series 3
-
1MHz to 1300MHz or 2700MHz frequency rangeResolution bandwidths of 300Hz to 10MHz 1:3:10-105dBm typical noise floor at -40dBm reference levelMeasurement in dBm or dBμV, mV or μWZero span mode with AM and FM audio demodulationTrace modes of normal, peak hold and trace averageLive, View (copy) and Reference traces in contrasting coloursTwin markers with readout of absolute & difference valuesSmart marker movement with selectable peak trackingFrequency counter with 10Hz ResolutionFrequency presets and independent state storageAuto-find automatically sets sweep parameters for the highest signal foundUnlimited storage for waveforms, set-ups and screensUser assignable file names, file stamping from real-time clockUSB interfaces for Flash drives and PC connectionComprehensive status and context sensitive help screensMore than 3 hours continuous operation from a chargeSmaller and lighter than other spectrum analyzers (weight only 0.58 kg)
-
Product
SH68M-68M-EPM, 68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable
190233-02
Multifunction Cable
68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable - The SH68M-68M-EPM Cable, sometimes referred to as SHC68-C68-EPM, connects DAQ devices. The cable includes separate digital and analog sections, individually shielded twisted pairs for analog … inputs, individually shielded analog outputs, and twisted pairs for critical digital I/O. The SH68M-68M-EPM Cable is offered in different lengths.
-
Product
0.35° Accuracy Roll & Pitch Surface Dynamic Motion Sensor
DMS-535RP
-
The DMS range of motion sensors is designed specifically for the motion measurement needs of the marine industry. Whether it is achieving IHO standard survey from any size of vessel, or providing safety critical monitoring of offshore platforms, large vessels, helicopter landing decks, cranes and positioning systems, the DMS provides accurate motion measurement in all sea conditions. Incorporating an enhanced external velocity and heading aiding algorithm for improved accuracy during dynamic manoeuvres, the solid state angular rate sensors offer reliability in the highest performing vertical reference units ever produced by TSS.
-
Product
Frequency Multipliers
-
RF coaxial frequency multiplier (also referred to as a coaxial frequency doubler) PE8600 from Pasternack has SMA conectors and are 50 Ohm. Our SMA frequency multiplier is manufactured for a minimum frequency input of 1.5 GHz and a maximum frequency input of 5 GHz. This SMA microwave frequency multiplier / doubler output minimum frequency is 3 GHz and output maximum frequency of 10 GHz.
-
Product
Crossed-Roller Bearing Linear Stage ,25mm Travel XYZ,Sensitivity 1um
NFP-3462
-
Model:NFP-3462 Crossed-Roller Bearing Linear Stage ,25mm Travel XYZ,Sensitivity 1um Details&Spec: Please refer to NFP-1462 Specification,It is combinated by 2pcs NFP-1462(C,SR,SL) and 1pc NFP-1462CZ(as vertcail stage)
-
Product
Microwave Wideband APD-TIA Receivers
MR12 (40KHz~18GHz)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
MR12 series microwave wideband optical receiver, adopts high Sensitivity APD diode and limiting amplifier, within bandwidth of 40KHz~18GHz, they are featured with excellent linearity, high responsibility and superior flatness of the RF response in both, power and phase. They provide an outstanding linearity fiber optical communication for analogue wideband microwave application. Due to avoidance of using expensive coaxial cable or wave-guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless, timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s high speed communication system.
-
Product
Primary Standards
-
Primary standards (often also referred to as mechanical dead-weight testers, pressure balances or primary pressure standards) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the primary standard an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port which measured through piston gauge technology.
-
Product
3-Channel 200 MHz A/D and 2-Channel 800 MHz D/A with Virtex-7 FPGA - 3U VPX
Model 52720
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Three 200 MHz 16-bit A/Ds- One digital upconverter- Two 800 MHz 16-bit D/As- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express (Gen. 1 and 2) interface up to x4- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
4-Channel 200 MHz A/D with DDC with Virtex-6 FPGA - 3U VPX
Model 52661
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 200 MHz 16-bit A/Ds- Four multiband DDCs (digital downconverters)- Multiboard programmable beamformer- Up to 2 GB of DDR3 SDRAM or 32 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factors provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Single Phase Site Energy Meter Test Instrument Type KP-P1001-A
-
Bofa Instrument & Equipment Co., Ltd
Single phase site energy meter test instrument type KP-P1001-A (without voltage and current source) is an ideal instrument to test all kind single phase energy meters accuracy below 1.0, especially for meters on site. During tests, the tested meter must be on load condition (that means the tested meter must be working). The instrument tests the errors by comparing energy impulse from the tested meter with energy impulse from the reference meter inside the instrument.
-
Product
8-Channel 200 MHz A/D with 64-Channel DDC, Virtex-6 FPGA - 6U VPX
Model 58662
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Eight 200 MHz 16-bit A/Ds- 64 channels of multiband DDCs (digital downconverters)- Up to 4 GB of DDR3 SDRAM- PCI Express (Gen. 1 & 2) interface up to x8- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
VXI Switching
-
The Aerospace and Defense industries were early adopters of modular test platforms. One of the first successes was VXI test systems and VXI switching. They served these industries very well for more than 20 years. Now, as VXI test systems become obsolete, test systems developers are looking to PXI as the next generation modular test platform for their industries. We offer a few different references to help you in making a switch to PXI.
-
Product
0.50° Accuracy Roll & Pitch Surface Dynamic Motion Sensor
DMS-550RP
-
The DMS range of motion sensors is designed specifically for the motion measurement needs of the marine industry. Whether it is achieving IHO standard survey from any size of vessel, or providing safety critical monitoring of offshore platforms, large vessels, helicopter landing decks, cranes and positioning systems, the DMS provides accurate motion measurement in all sea conditions. Incorporating an enhanced external velocity and heading aiding algorithm for improved accuracy during dynamic manoeuvres, the solid state angular rate sensors offer reliability in the highest performing vertical reference units ever produced by TSS.
-
Product
X2 GPIB Cable,Double-Shielded,Shielded Plug/Receptacles,4 m
763061-03
GPIB Cable
24-Pin Male/Female GPIB to 24-Pin Male/Female GPIB, Stackable, Double-Shielded GPIB Cable - The 24M/F-24M/F X2 Cable, sometimes referred to as an X2 cable, connects your system to GPIB devices or interfaces for instrument control. The 24M/F-24M/F X2 Cable has 24-pin IEEE 488 male and female connectors, and the cable is double shielded with shielded plug/receptacles. The 24M/F-24M/F X2 Cable is also offered in different lengths.
-
Product
Waveguide Switches
-
Waveguide switches are electromagnetic switches with hollow circular or rectangular cross-sections and are used for routing RF energy in microwave communications, broadcasting, and in radar applications. Waveguide switches can be used to transfer both power and communication signals, and the bandwidth of a waveguide is in relation to its size, and thus always referred to by its size (e.g. WR112, WR90, WR75 etc.). Compared to coaxial switches, waveguides can route extremely high power signals over a narrow bandwidth at low to high frequencies, and now Lightweight Waveguide series is available.
-
Product
4-Ch 500 MHz A/D with DDC & 4-Ch 800 MHz D/A with DUC, Virtex-7 FPGA - 6U VPX
Model 58751
-
- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Two or four 500 MHz 12-bit A/Ds- Two or four multiband DDCs (digital downconverters)- One or two DUCs (digital upconverters)- Two or four 800 MHz 16-bit D/As- 4 or 8 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 & 3) interface up to x8- LVPECL clock/sync bus for multiboard synchronization- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Optional 400 MHz 14-bit A/Ds- Ruggedized and conduction-cooled versions available- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Multi-Potentiostat
1000C
-
The model 1000B series is a computerized 8 channel potentiostat. The system contains a digital function generator, multiplexed data acquisition circuitry, and a multi-potentiostat that can work with eight independent cells or eight working electrodes in the same solution with common reference and counter electrodes. The potential control range is 10 V for all channels, which can be set at independent potentials or the same potential as the primary channel, so that they can sweep or step potentials together with the primary channel.
-
Product
PPID-2000 Photosynthetic Photon Intensity Distribution Test Unit
-
Hangzhou Everfine Photo-E-Info Co., LTD
It is mainly used for testing plant lighting products. With the EVERFINE GO-R5000 goniophotometer system, it can realize the measurement of plant photosynthetic photon intensity distribution (μmol/s/sr) in the whole space. In addition, the device can also realize the test of photosynthetic photon flux, far red light photon flux, photosynthetic radiation efficiency and other parameters, referring to DLC, ASABE, DIN, GB, CQC and CSA related international plant lighting standards .
-
Product
Frequency Shaped Isotropic Electric Probes
PI-SH-FCC, PI-SH-ICNIRP
-
An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.
-
Product
8 CANBus Channels, J1939 Protocol
CB2
-
The serial bus system with real-time capabilities is the subject of the ISO 11898 International Standard and covers the lowest two layers of the ISO/OSI Reference Model. Our CANBus modules provide independent, isolated channels of CAN serial data bus links, conforming to the ISO 11898 International Standard. All CAN nodes are able to transmit data and several CAN nodes can request the bus simultaneously.
-
Product
2-Ch 500 MHz A/D with DDC & 2-Ch 800 MHz D/A with DUC, Virtex-7 FPGA - XMC
Model 71751
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- Two 500 MHz 12-bit A/Ds- Two multiband DDCs (digital downconverters)- Two 800 MHz 16-bit D/As- One DUC (digital upconverter)- Multiboard programmable beamformer- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- VITA 42.0 XMC compatible with switched fabric interfacesOptional LVDS connections to the Virtex-7 FPGA for custom I/OAlso available in 3U VPX, 3U & 6U cPCI & PCIeSupports GateXpress® FPGA-PCIe Configuration ManagerSynchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
-
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.





























