Product
RH Calibrator / Dew Point Generator
-
Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.
-
Product
Three Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
Product
Short Circuit Finders
-
The ShortSniffer locates short circuits in electronics circuits, projects, and printed circuit boards. * locates PCB shorts under solder mask, under components, and even on inner PCB layers * non-contact (inductive) pickup wand * pinpoint short to within 2mm radius (SS2) * rapid location with audio feedback * "follow the sound to the short" * no need for relative or reference measurements * battery operated * diode clamped current drive, won't harm your circuitry
-
Product
Dipole Antenna
AD-100
-
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
Product
Calibration Software
-
AMETEK Sensors, Test & Calibration
Our calibration software provides an easy way to calibrate gauges, RTD´s, thermocouples, transmitters, thermoswithes, and pressure switches. Complete a full calibration from entering the details of the gauge to printing out a calibration certificate. Reduce operating time by automating calibration procedures, reduce sources of error by automatically reading and storing values from the reference, and customize certificate templates to fit your needs.
-
Product
New Design 3m Electric Integrating Sphere
IS-3.0MA
-
It has all functions of IS-*MA Integrating Sphere with Holder Base.• Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere.• Please refer to article The New Design 3m Electric Integrating Sphere for more information.
-
Product
Standard Capacitors
1408 Series
-
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.
-
Product
Frequency Reference
-
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
Product
PD Coupler
-
Techimp Capacitive PD Couplers offer both the PD and sync signals references, allowing a thorough investigation of the signal originating inside the asset they are connected to.Techimp Couplers are individually tested according to the following international standards: IEC60358; IEC60694; IEC60270.
-
Product
X13 GPIB Cable, MicroD25 to Shielded cable/Standard connector, 0.2M
183285-0R2
GPIB Cable
24-Pin Male/Female GPIB to 25-Pin Male Micro D-SUB GPIB Cable - The 24M-24F-MicroDB25M X13 GPIB Cable, sometimes referred to as the X13 cable, connects your system to GPIB devices or interfaces for instrument control. This standard shielded cable can connect PXI Controllers to instrument control devices and is offered in different lengths.
-
Product
2-Channel ADC Module
FMC161
-
Sundance Multiprocessor Technology Ltd.
The FMC161 provides one 12-bit A/D channel at 3.6Gsps or two A/D channels at 1.8Gsps clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users. The FMC161 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
Product
Paramagnetic Oxygen Analyzer
Model T802
-
The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T802 comes with the NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Carrier Boards
ROM-DB7501
Carrier Board
ROM-DB7501 is an Referenced Carrier Board designed for Advantech's RISC Qseven 2.0 module. It i provides a thorough environment for module board evaluation with its completefunction support. It also supports 12V power input through AC/DC power adapter and with smart battery design, it's more easier for the end user to design portable devices by referring ROM-DB7501 design.
-
Product
Environmental Monitoring
-
Environmental monitoring refers to the tools and techniques designed to observe an environment, characterize its quality, and establish environmental parameters, for the purpose of accurately quantifying the impact an activity has on an environment.
-
Product
Bus Analyzer
FireSpy430b(T)/830b(T)
-
The FireSpy430b(T) and FireSpy830(bT) bus analyzers are the single bus models in the 4th generation of IEEE-1394 analyzers from DapTechnology. Based on the industry leading FireSpy810 the all new and enhanced architecture of the FireSpy430b(T)/830b(T) have again defined a new reference in IEEE-1394 test equipment! They comprise a significantly more powerful on-board processor, more memory and improved connectivity to the host.
-
Product
Eddy-Current Sensors
-
Eddy-Current sensors are noncontact devices capable of high-resolution measurement of the position and/or change of position of any conductive target. Eddy-Current sensors are also called inductive sensors, but generally "eddy current" refers to precision displacement instruments (or nondestructive testing probes) and "inductive" refers to inexpensive proximity switches. High resolution and tolerance of dirty environments make eddy-current sensors indispensable in today's modern industrial operations.
-
Product
Structured Wiring
-
Structured wiring refers to a whole-house network of audio, video, data, telephone, television, home automation or security signals. This wiring can be installed when a home is being built. It may be put in during a remodel. Structured wiring can also be added on its own.
-
Product
Multi-Channel Clock Generator
XCLK1
-
Curtiss-Wright Defense Solutions
High-speed analog IO acquisition systems need a high quality master reference sample clock.Accurate synchronization in the 100MHz and up frequency domains is not easy and it’s a critical performance limiting factor if not done well. The XCLK1 multi-channel clock generator solves these problems.
-
Product
Fixed-Mount Thermal Camera for Elevated Skin Temperature Screening
FLIR A320 Tempscreen
-
The FLIR A320 Tempscreen camera is preconfigured for monitoring individuals to find temperature deviations or elevated skin temperature, including difference temperature alarms with a dynamically updated reference temperature. This temperature measurement solution offers built-in analysis, alarm functionality, and autonomous communication using standard protocols. The FLIR A320 Tempscreen also has features and functions to build distributed single- or multi-camera solutions utilizing standard Ethernet hardware and software protocols.
-
Product
Fiber Optic Navigation Systems
SATURN
-
SATURN, from Teldyne TSS, is a world leading marine navigation system for surface applications. Built on TSS core fibre optic gyro technology giving unparalleled attitude and heading reference system (AHRS) performance. SATURN offers a fast alignment time of only 10 minutes, from switch-on.It has been designed to address a market need for cost-effective products with competitive specifications for surface use including survey vessels, workboats and commercial shipping vessels. Based on proven FOG technology, and with no moving parts, SATURN is maintenance-free with high MTBF. It is available in three standard heading accuracy variants; 0.1° sec lat (SATURN10), 0.3° sec lat (SATURN30) and 0.5° sec lat (SATURN50).
-
Product
LTE/LTE-Advanced Multi-Channel, Reference Solution
-
Gain greater insight faster with a compact, multi-channel LTE-A PXI signal generator and signal analyzer reference solution.This Reference Solution uses world-class Signal Studio software to create complex LTE-A waveforms and the 89600 VSA/WLA software to connect to multiple analyzers. The VSA software allows engineers to quickly view multiple antenna elements simultaneously and analyze the RF performance and modulation domains for timing and signal quality issues in complex carrier aggregation and MIMO/beamforming designs.
-
Product
GPS Master Clock
-
Signals & Systems India Private Limited
GPS Master Clock System – MCS-GPSMC-1010 is a 3U Card rack type, 19” Rack-mountable Redundant GPS Time Server which synchronizes and maintains the timing and frequency requirement of power and process industry equipment using a signal obtained from any one of the sources like GPS or GLONASS or Time protocols such as NTP and IRIG. It distributing the same time signal through several types of interfaces. It provides redundancy for Power and GPS receiver to increase reliability and offers protection against time synchronization failure. The system is field-upgradeable and an extremely flexible system, designed to handle time synchronization requirements today and in the future. It provides nanosecond accuracy when external time references are not available. It has a storage facility to store the system log file. It delivers NTP, SNTP, IRIG-B, PFC-Pulse, DCF77, BCD parallel data, Ethernet Fiber Optic & RS485/RS232 outputs. System enables configuration and monitoring through Web-based application. It supports a wide range of power supply either 90V-260V AC/DC or 18-36VDC or 36V-72VDC. Power supply model can be mixed and matched as required by the user, depending upon power supply options available at the installation site.
-
Product
4210A Rubidium Frequency Standard
-
Precise Time and Frequency, Inc.
The ptf 4210A Rubidium Frequency Standard is a unique solution for providing a highly stable, low phase noise, frequency reference for applications requiring atomic reference stability performance.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
Type T7 Fiber-Optic Cable for GPIB-140, ST conn., Core/Clad 62.5/125 um, 850 nm Wavelength, 30 m
182805-030
Fiber-Optic Cable
2-Pin Male to 2-Pin Male, Core/Clad 62.5/125 um, 850 nm Wavelength Fiber-Optic Cable for GPIB-140A Extender - The GPIB T7 Cable, sometimes referred to as GPIB Cable, connects your system to high-speed GPIB-140A extender devices. You can use the GPIB T7 Cable with a GPIB extender to increase the cable length of your system up to 1 km without comprising the integrity of your GPIB system or requiring any application modifications. The GPIB T7 Cable is offered in different lengths.
-
Product
Advanced Mezzanine Card (AMC) Module
AMC SyncClock32
-
The AMC-SyncClock32 from Brandywine Communications is an Advanced Mezzanine Card (AMC) module. Precision time is provided to the host computer with zero latency. The onboard microprocessor automatically synchronizes the clock to reference signal inputs. The reference signal inputs handled by the AMC in its standard configuration are IRIG’s A, B/IEEE1344, and NASA 36. Alternatively, the clock in the AMC can be set using commands from host computer and free run using its on-board oscillator as the time base.
-
Product
Multi-function GPS/GLONASS Research Receiver
R100
-
The Multi-function GPS/GLONASS Research Receiver sets the standard in precision and versatility for GPS/GLONASS research. It provides highly accurate navigation, ionospheric measurement, time transfer, satellite monitoring and differential reference station capabilities. When combined with the temperature stabilized antenna it eliminates delay variations due to outside temperature, affording even greater accuracy.
-
Product
Scan To CAD
-
Scanning or hard probing, large or small, we have a large arsenal of hardware & software to fit our clients’ needs. With all the reference data coming directly from the CAD model this eliminates any human error that would have come through manually entering nominal information.
-
Product
Slag & Refractory Reference Materials
-
NCS Testing Technology Co., Ltd.
Slag & Refractory Reference Materials by NCS
-
Product
Cable Assembly, 200-Pin LFH, Male Bottom Exit (Male Screwlocks) to 4x50-Pin D-type, Female, 2m
A200LMB-04F050D5B200
Cable Assembly
This 200-pin male to 50-pin female D-type 2m long cable assembly is suited for direct connection to all Pickering Interfaces products using the 200-Pin LFH connector and is constructed from 4 bundles of 50-wire round/flat ribbon cable. The connector assembly can be secured to the product by screwlocks. This cable assembly can be used with Pickering 50-Pin D-Type connector blocks (refer to 90-005D).
-
Product
Three Phase Site Energy Meter Test Instrument Type KP-P3001-A
-
Bofa Instrument & Equipment Co., Ltd
Three-phase site energy meter test instrument type KP-P3001-A (without voltage and current source) is an ideal instrument to test all kind three-phase energy meters accuracy below 0.2, especially for meters on site. When we want test a meter errors, the tested meter must be on load condition (or we can say the tested meter must be working). The instrument can test the errors, by comparing energy impulse from the tested meter with energy impulse from the reference meter which inside the instrument. The equipment is box structure and weight is very light, easy to carry, it is very convenience to test the installed meters on site.