Passive Intermodulation
1.) Protocol Independent Multicast - network routing over existing unicast framework. 2.) Passive InterModulation - RF interference generation condition.
-
Product
Components - Passive Multipliers (FT)
FT Series
-
Farran Technology manufactures a series of standard frequency multipliers which are available in fixed or tunable versions. GaAs Schottky barrier varactors are used to achieve the highest efficiency. The multipliers can be used with solid state or vacuum tube sources. A rugged compact mechanical design is used to maximise reliability.
-
Product
Extreme Temperature Passive Probe
N7007A
Oscilloscope Probe
Many environmental test engineers today are using standard-temperature probes in extreme temperature condition, which causes physical damage to the probe. Another common practice among environmental test engineers is to simply attach long wires at the end of their probes, which significantly degrades measurement performance due to excessive inductance and reduced bandwidth. Keysight addresses this issue with the N7007A single-end passive probe.
-
Product
Passive XMC-to-PCI Express Adapter
5944
-
The Technobox, Inc. P/N 5944 is designed to adapt a single-wide XMC card to a 16X PCI Express slot. The 5944 supports both P15 and P16 and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
Passive Probe, 100:1, 1.5 GHz, 1.3 M
N2876A
Oscilloscope Probe
The N2876A passive probe offers DC to 1.5 GHz and 100:1 attenuation factor to measure fast edges in high speed applications more accurately. This probe needs 50 Ω input on the oscilloscope.
-
Product
SP500X , 500 MHz, ±300 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
783629-01
Oscilloscope Probe
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
Product
6 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 6 Ports
GPS612
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.5 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
Passive Fiber Network TAPs
-
Passive network test access points (TAPs) are a hardware tool that allows you to monitor your network. Garland Technology offers fiber network TAPs in network speeds of 1Gb, 10Gb, 40Gb and 100Gb. Fiber Network TAPs are passive, purpose-built hardware devices that make a 100% copy of your networks data - without affecting network traffic. Passive network TAPs let your monitoring tools to see every bit, byte and packet®.
-
Product
Passive XMC-to-PCI Express Adapter
6066
-
Our Passive XMC-to-PCI Express Adapter +5VPWR 4X (6066) is designed to adapt a single-wide XMC card to a 4X PCI Express slot. The 6067 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card.
-
Product
GPS Antenna Signal Splitter 3 Way, SMA Jack, Passive, L1 & L2, 50 Ohm
GPS310
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsRoHS Compliant Splitter Construction
-
Product
6-slot ATX-supported PICMG Bus Passive Backplane (vertical)
ATX6022/6VP4
-
*1 PICMG, 4 PCI and 2 ISA*Compatible with AX61222TP/AX61220TP*Supports ATX power supply*For 2U chassis
-
Product
2 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, N Type, DC Block+200Ω Load 2 Ports
GPS202
-
INSTOCK Wireless Components, Inc
PS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
Product
4 Way GPS / GNSS Signal Splitter IP67 Outdoor, N Type, 1-2 GHz, 50 Ohm, Passive
GPS401
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
Product
Thick Film Passive Element
GBR-253
-
GBR-253 series high voltage resistors are made in a thick film technology on ceramic substrates (Al2O3 96%). These elements are used in high voltage applications requiring high stability and resistance.
-
Product
4 Way GPS / GNSS Signal Splitter IP67 Outdoor, SMA, 1-2 GHz, 50 Ohm, Passive
GPS411
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
13-slot ATX-supported PICMG 1.3 Bus Passive Backplane
FAB113
-
*Designed for PICMG 1.3 SBC*Compatible with the AX61400, AX6145, and AX6156LE chassis*Supports one PICMG 1.3 CPU card slot, seven PCIe x1 slot, one PCIe x16 slot, and four 32bit/33MHz PCI slots
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
2 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 2 Ports
GPS212
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
Thick Film Passive Element
GBR-403
-
GBR-403 series high voltage resistors are made in a thick film technology on ceramic substrates (Al2O3 96%). These elements are used in high voltage applications requiring high stability and resistance.
-
Product
Passive Temperature-Humidity Transmitters
HD49… Series
-
HD49 transmitters are designed for temperature and humidity control in conditioning and ventilation applications (HVAC/BEMS) in the following sectors: pharmacy, museums, clean rooms, ventilation ducts, industrial and civil sectors, crowded places, canteens, auditoria, gyms, high-density farms, greenhouses, etc.
-
Product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Probe, 10:1, 500 MHz, 1.5 M
10073D
Oscilloscope Probe
The Keysight 10073D passive probe is our most rugged 500 MHz probe. With a 10:1 attenuation ratio and high 2.2 M ohm input impedance, it is ideal as a general purpose, high bandwidth passive probe for the Keysight 300 MHz - 1 GHz 6000 series, 7000, 8000 and 9000 Series oscilloscopes. The probe identification feature automatically configures the oscilloscope for the probe attenuation.
-
Product
10:1, 10 Mohm, 300 MHz Passive Probe
PP016
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
13-slot ATX-supported PICMG 1.3 Bus Passive Backplane
FAB119
-
*Designed for PICMG 1.3 SBC*Compatible with AX6145, AX61400, and AX6156LE chassis*Supports one PICMG 1.3 CPU card slot, one PCIe x4 slots, one PCIe x16 slot, and ten 32bit/33MHz PCI slots






















