Passive Intermodulation
1.) Protocol Independent Multicast - network routing over existing unicast framework. 2.) Passive InterModulation - RF interference generation condition.
-
Product
RS-232 Passive Tap Module
EZ-TAP™
-
Stratus Engineering’s EZ-Tap hardware module is a low-cost hardware bus analyzer and protocol analyzer solution that uses a traditional dual COM port approach to RS232 interface monitoring.
-
Product
Passive XMC-to-PCI Express Adapter
5934
-
The Technobox, Inc. P/N 5934 is designed to adapt a single-wide XMC card to a 4X PCI Express slot. The 5934 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
Thick Film Passive Element
GBR-395
-
GBR-395 series high voltage resistors are made in a thick film technology on ceramic substrates(Al2O3 96%). These elements are used in high voltage applications requiring high stability and resistance.
-
Product
6kV High Voltage Passive Probe, 500 MHz
PPE6KV-A
-
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
Product
Passive Frequency Multipliers
-
The frequency multiplier which generates output with power level less than input power.
-
Product
Passive Probe, 10:1, 300 MHz, 1.2 M
N2842A
Oscilloscope Probe
The Keysight N2842A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
Product
Passive Network TAPs
ApconTap
-
Our portfolio of passive optical network TAPs captures network traffic under all conditions to simplify network monitoring and security. Each ApconTap model supports common datacenter optical fiber standards with split ratio options availble at 50/50, 60/40, and 70/30. With passive fiber 40G and 100G TAPs, APCON offers short-range, long-range, and bidirectional models to accomodate requirements for high-density, next-generation datacenter deployments.
-
Product
13-slot ATX-supported PICMG Bus Passive Backplane
ATX6022/13L
-
*1 PICMG, 4 PCI and 8 ISA*Compatible with AX61400, AX6145, and AX6156LE*Supports both AT and ATX power supply
-
Product
Power Dividers/Combiners (Passive & Active)
-
PMI offers the highest quality power divider's and power combiner's for commercial and military applications in the frequency range of a few MHz to 40 GHz.
-
Product
Passive probe with X1/X10 switch
-
They are normally designated X1 and X10, although 1X and 10X are sometimes seen. The designation refers to the factor by which the impedance of the scope itelf is multiplied by the probe.The X1 probes are suitable for many low frequency applications. They offer the same input impedance of the oscilloscope which is normally 1 MΩ. However for applications where better accuracy is needed and as frequencies start to rise, other test probes are needed.
-
Product
Other Passive Probes
-
Probes connect the input of the oscilloscope to test points on the device under test (DUT). There are many types, including: high impedance passive, low capacitance, single-ended active, differential active, high voltage, and current probes. This is the first in a series of three articles on probe selection and application, and will focus on passive probes. Part 2 and part 3 will address active probes and current probes, respectively.
-
Product
Passive Devices
-
Fiber Splitters, Muxes, CWDM, DWDM, WDM, PON, Fiber Jumpers, Fiber Attenuators.
-
Product
Passive Magnetic Antennas, TX-Loop Antennas
-
A passive loop antenna which is matched to a resonance frequency of 13.56 MHz with 370 kHz bandwidth (-3dB)The purpose of the antenna is to produce defined magnetic fields at 13.56 MHz efficiently, i.e. to test near field communication devices (NFC) or RFID equipment.
-
Product
Intermodulation Distortion Measurements For M980xA PXI VNA
S95087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) using the S95087B software application with the M980xA PXI VNA.
-
Product
Passive Backplanes
Backplane
A wide range of ADLINK backplanes are available for PICMG CPU cards. They are the most flexible and expansible solutions for industrial slot-hungry applications.
-
Product
OX 773 WDM Node (Passive)
-
Sharp Vision OX 773 1 PON + 2 CATV Passive WDM Node in a ABS Cabinet.- No Power Supply- Built in WDM- Output Level: 65 dB- Frequency: 40 ~ 900 MHz
-
Product
Passive Probe, 100:1, 1.5 GHz, 1.3 M
N2876A
Oscilloscope Probe
The N2876A passive probe offers DC to 1.5 GHz and 100:1 attenuation factor to measure fast edges in high speed applications more accurately. This probe needs 50 Ω input on the oscilloscope.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
MPU- Passive Sensors
-
sensors of the MPU series are passive elements intended for measuring rotational speeds or speeds of moving parts. The measuring principle is based on voltage induction in the coil through a changing magnetic field, which is caused, for example, by a rotating ferromagnetic gear. The coil is wound on a magnetic core and led out via a cable or a plug. The sensors are manufactured with metric or inch threads or with a flange connection and deliver a sinusoidal output signal, the amplitude of which is proportional to the peripheral speed. They can be connected to Orbit Controls evaluation devices. An OC35-IMP transmitter is available for converting to square-wave signals.
-
Product
Passive XMC-to-PCI Express Adapter
5933
-
The Technobox, Inc. P/N 5933 is designed to adapt a single-wide XMC card to an 8X PCI Express slot. The 5933 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
Passive Devices
-
Passive Devices by Senko - attenuators, fused products, optical switches, plc splitter series, routing, WDM series, and more
-
Product
Passive Probe
PP011-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Probe Accessory Kit For N2140A
N2141A
Accessory Kit
The Keysight N2141A accessory kit includes all of the standard accessories for N2140A passive probes.
-
Product
Thick Film Passive Element
GBR-183
-
GBR-183 series resistors are made in a thick film technology, on ceramic substrates(Al2O3 -96%). Thick film resistors are characterized by a higher stability, and lower noises than a typical carbon resistors. The whole of resistor is encapsulated with epoxy resin by fluidization process. GBR-183 series elements are used both for general, and professional applications.
-
Product
Thunderbolt 3 Type-C Cable, Passive 20 Gbps, 5A, 2m
785608-02
USB Type C
24-Pin USB-C Male to 24-Pin USB-C Male Thunderbolt™ Cable - The Thunderbolt 3 Male-to-Male Cable provides a USB-C connection for PXI chassis and controllers. This cable supports passive or active 40 Gbps or passive 20 Gbps data transfer speeds. The Thunderbolt 3 Male-to-Male Cable is available in 0.8 m or 2 m lengths. Thunderbolt and the Thunderbolt logo are trademarks of Intel Corporation or its subsidiaries in the US and/or other countries.
-
Product
GPS, GLONASS, Galileo Micro Splitter 2 Way, SMA, 1176.45 - 1602.00 MHz, 50 Ohm, Passive
GPSL12
-
INSTOCK Wireless Components, Inc
GPSL12 is a two way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power remotely located active GPS antennas from the receivers. Maximum voltage rating is 50 VDC; max current rating is 1000 mA. Furnished with SMA female connectors all ports. Being a "micro-sized" splitter, GPSL12 weighs only 21 grams and is suitable for applications requiring low-weight parts.
-
Product
GPS, GLONASS, Galileo Splitter 6 Way, TNC, 1000 - 2000 MHz, 50 Ohm, Passive
GPS620
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy TNC Female (Jack) 50 Ohm
-
Product
Passive Probe, 10:1, 500 MHz, 1.2 M
N2843A
Oscilloscope Probe
The Keysight N2843A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.





























