Passive Intermodulation
1.) Protocol Independent Multicast - network routing over existing unicast framework. 2.) Passive InterModulation - RF interference generation condition.
-
Product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Thunderbolt 3 Type-C Cable, Passive 20 Gbps, 5A, 2m
785608-02
-
24-Pin USB-C Male to 24-Pin USB-C Male Thunderbolt™ Cable - The Thunderbolt 3 Male-to-Male Cable provides a USB-C connection for PXI chassis and controllers. This cable supports passive or active 40 Gbps or passive 20 Gbps data transfer speeds. The Thunderbolt 3 Male-to-Male Cable is available in 0.8 m or 2 m lengths. Thunderbolt and the Thunderbolt logo are trademarks of Intel Corporation or its subsidiaries in the US and/or other countries.
-
Product
Passive Probe Accessory Kit For N2140A
N2141A
-
The Keysight N2141A accessory kit includes all of the standard accessories for N2140A passive probes.
-
Product
4 Way GPS / GNSS Signal Splitter IP67 Outdoor, SMA, 1-2 GHz, 50 Ohm, Passive
GPS411
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
Passive Probe, 10:1, 350 MHz, 1.3 M
N2872A
Oscilloscope Probe
Compact 2.5-mm probe head diameter, low input capacitance, and various fine-pitch probe tip accessories make the Keysight N2870A Series passive probes ideal for probing densely populated IC components or surface-mount devices used in today’s high-speed digital applications.
-
Product
Passive XMC-to-PCI Express Adapter
6067
-
The Technobox, Inc. P/N 6067 is designed to adapt a single-wide XMC card to a 1X PCI Express slot. The 6067 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O. JTAG signals are brought out to headers allowing users the option of connecting the two JTAG ports.
-
Product
3 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 3 Ports
GPS312
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
8 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 8 Ports
GPS812
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
GPS Antenna Signal Splitter 3 Way, SMA Jack, Passive, L1 & L2, 50 Ohm
GPS310
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsRoHS Compliant Splitter Construction
-
Product
2 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 2 Ports
GPS212
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
Passive Probe, 10:1, 300 MHz, 1.2 M
N2842A
Oscilloscope Probe
The Keysight N2842A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
High Current Probe
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Atlas LCR Passive Component Meter
LCR40
-
The Atlas LCR40 automatically identifies and analyses almost any passive component (Inductor, Capacitor or Resistor). It measures its parameters using automatically selected test frequencies (DC, 1kHz, 15kHz and 200kHz).
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
High Current Probe
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
Oscilloscope Probe
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
Product
Passive XMC-to-PCI Express Adapter
5934
-
The Technobox, Inc. P/N 5934 is designed to adapt a single-wide XMC card to a 4X PCI Express slot. The 5934 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O.
-
Product
3 Way GPS / GNSS Signal Splitter IP67 Outdoor, SMA, 1-2 GHz, 50 Ohm, Passive
GPS311
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
GPS, GLONASS, Galileo Splitter 8 Way, TNC, 1000 - 2000 MHz, 50 Ohm, Passive
GPS820
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy TNC Female (Jack) 50 Ohm
-
Product
Passive Probe
ENVI
-
PMK Mess- und Kommunikationstechnik GmbH
The world's first modern probe for this high temperature range is suitable for a variety of applications with an input voltage range of 400V / 1250V peak, 10:1 divider and 350MHz bandwidth.The individual and signal-true contacting for different applications is guaranteed by the exchangeable spring tip and a variety of contacting accessories.
-
Product
Intermodulation Distortion Measurements
S96087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S96087B software application with the ENA
-
Product
Free Data Monitoring Software For EZ-Tap™, EZ-Pro™, And Versa-Tap™ Passive Tap Modules
-
Stratus Engineering's EZ-View™ data monitoring program controls communication and data collection parameters and displays time-tagged communication data and handshaking events in an easy-to-use scrolling display window.
-
Product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
400 MHz High Voltage Passive Probe
HVP120
-
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
Product
BenchMate Passive- Air Vibration Control
2210 Series
-
BenchMate Vibration-Free Platforms enhance the performance of precision tabletop equipment.The 2210 Series features a Passive-Air design requiring periodic manual leveling.
-
Product
13-slot ATX-supported PICMG1.3 Bus Passive Backplane
FAB114
-
The FAB114 has a PICMG 1.3 CPU card slot, one PCI Express x16 slot, three PCI Express x1 slots and a total of eight 32bit/33MHz PCI slots. The onboard 24-pin ATX power connector and 8-pin connector for thermal detected board are featured. Through one PCIe x16 link, this PICMG 1.3 backplane maximize the performance of high-end PCI Express graphics and video cards. Furthermore, the backplane supports two high speed USB 2.0 ports. The FAB114 is perfect fit for AXIOMTEK's SHB100 and SHB110. AXIOMTEK also offers versatile 4U industrial chassis specially design for the FAB114, such as the AX61400, AX6156 series and AX61491.
-
Product
Passive Pulse Splitter
SY037
-
The SY037 passive pulse splitter is ideal for converting pulses from meters or other turbine devices and transmitting the same pulse to three outputs to enable three separate instruments to measure the rate simultaneously. It needs no power supply. It functions simply from the pulses of the meter driving it. It is convenient for meters and any pulse generating device with reed switches, open collector or current source.
-
Product
Passive Devices
-
Passive Devices by Senko - attenuators, fused products, optical switches, plc splitter series, routing, WDM series, and more
-
Product
5-slot ATX-supported 2U Butterfly PICMG 1.3 Bus Passive Backplane
FAB205
-
The FAB205 features a PICMG 1.3 CPU card slot, five 32bit/33MHz PCI slots, and built in a 24-pin ATX power connector and 8-pin connector for thermal detected board. The FAB205 is optimized to support AXIOMTEK's PICMG 1.3 system host boards, the SHB100 and SHB110, which are built around the PICMG 1.3 form factor. The FAB205 is compatible with the AX61220/AX61222 chassis.
-
Product
4 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 4 Ports
GPS412
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm