Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkiye
-
Product
Sensing Resistors
Resistive Voltage Dividers
-
NGR Sensing Resistors are attached in parallel to the neutral grounding resistor. The sensing resistor allows a protective relay to detect a resistor failure in a continuous manner. Sensing Resistors are used in combination with neutral grounding resistor monitor relays. The relay measures neutral grounding resistance, neutral grounding resistor current and neutral to ground voltage. The relay continuously measures neutral grounding resistor ohmic value in an unfaulted system and it trips on if neutral grounding resistance varies from its calibrated value.
-
Product
Iron Core Current Limiting Reactors
-
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
Product
LV Iron Core Motor Starting Reactors
-
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
Product
Explosion-Proof Heaters
-
Explosion-Proof Heaters (ATEX certified) provide neutral convection solutions of heating for electrical equipments in hazardous industrial locations where potential for explosion exists due to the presence of flammable gases, vapors, powder-metals or dusts.
-
Product
Air Core Line & Load Reactors
-
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Product
Air Core Current Limiting Reactors
-
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
Product
Crowbar Resistors
-
Crowbar resistors are three phase resistance banks which are connected to the rotor windings of the DFIG (Doubly-Feed Induction Generator) such as wind power generator. They are used to prevent damage to the inverter circuits attached to rotor side when a fault occurs in the grid. DFIG power converter, which has a restricted over-current limit, needs special attention during faults in the grid. If the rotor current or DC link voltage reaches the threshold value, crowbar resistors disconnect the converter in order to prevent the generator turning into a squirrel cage induction machine. By crowbar resistors, the DFIG could stay connected to the grid and continue its operation.
-
Product
Combined Load Banks
C-Series
-
C-series combined load banks are devices which contain resistive and reactive loads, apply the load to an electrical power source and dissipate the power of the electrical power.
-
Product
Air Core Motor Starting Reactors
-
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
Product
Radiator Mounted Load Banks
RD-Series
-
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
Product
Air Core Neutral Grounding Reactors
-
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
Product
LV Iron Core Smoothing Reactors
-
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems. They are necessary in order to smooth the direct current wave shape to reduce losses and improve system performance.
-
Product
Air Core Test Lab Reactors
-
Test Laboratory Reactors are designed for high voltage and high power test laboratories. They are designed to withstand the most extreme electrical service conditions during test periods. Design techniques are implemented in accordance with the most demanding service conditions. These reactors are used for various purposes in test laboratories such as current limiting and synthetic testing of circuit breakers, capacitor testing, artificial line simulation etc.
-
Product
PLC Line Traps
-
Line Traps are used in transmission and distribution networks and they are the key components in Power Line Carrier (PLC) systems used for remote control signals, voice communication, remote metering and control between substations in the electrical T&D networks.
-
Product
Reduced Voltage Motor Starting Panels by Auto-Transformers
-
Reduced Voltage Motor Starting Panels are designed for starting of squirrel cage induction and synchronous motors. A RVMS Panel reduces the torque by temporarily reducing the voltage and/or current input. It reduces voltage applied to the motor during start up causing lower starting currents from the connected grid.