LXinstruments GmbH
The LX instruments GmbH was originally founded in 2006 as a solution provider for all questions relating to instruments and systems of electronic measurement technology. Schwerpunktmäßg our systems are based on the LXI Standard (LAN based Extensions for Instrumentation), an open industry standard.
- +49 (0) 7032 / 895 93-0
- +49 (0) 7032 / 895 93-18
- info@lxinstruments.com
- Rudolf-Diesel-Str. 36
Nufringen, 71154
Germany
-
Product
Hipot & Security Tester
-
Safety testers (also called hipot testers) ensure the safe use of test items in different working environments and under different operating conditions. There are a variety of solutions, depending on the tests required to meet the relevant industry standards. Many test units offer a combination of functionality and performance.
-
Product
Leakage Test
-
Leakage current and discharge current depend on the insulation of the device. The measurement simulates various fault situations that could occur during operation. The test determines whether the measured current is within the permissible limits and poses no danger to the user in case of a fault.
-
Product
Measurement and Analytics Solutions
-
Based on our OTP² system platform, we were able to implement a family of scalable test systems which is based on a common systems architecture, e. g. for products in the area of chemical analytics measurement. We not only implemented a universal, extremely comprehensive test system, but also a series of compact systems for benchtop placement which are fully compatible with the larger, universal system. Our specialized self-test adapters and test software enable fast verification of the test systems as well as partly automated calibration by the customer.Our systems are also used in electrical measurement applications, e. g. for calibrating analog input assemblies for PLC technology. For this purpose, specialized calibrators are integrated into the system; they provide traceable calibration of the relevant stimulus signals.
-
Product
AC / DC - Power Supplies
-
The spectrum of DC power supplies ranges from simple power adapters with only one output voltage to complex controllable power sources. Power adapters, often also called plug-in mains adapters, are mainly used for small electrical appliances (such as telephones, strings of light, notebooks, etc.) in private households. They are included in the scope of delivery of the product and only serve to supply power with a defined output voltage of 6 V or 12 V, for example. The output power is usually limited to < 200 W due to the simple design.
-
Product
Compact System for Chemical Analysis Technology
-
Small test system based on the LXinstruments OTP2 system platform. The system is used for assembly, final test and calibration of measuring instruments for chemical analysis in a high mix / medium volume environment.
-
Product
Electrical Safety Testing
-
Manufacturers and operators of electrical equipment are required to carry out an electrical safety test within the framework of the applicable regulations. This is to prevent accidents caused by malfunctions in electrical equipment, such as fire, explosion as well as injuries and personal damage. The tests to be carried out are specified in national (VDE/DIN) and international (EN/IEC) standards. After passing the test, the product is considered safe for the entire life cycle, provided it is left in its original condition and used for its intended purpose.
-
Product
PXI RS232 Interface Galvanic Isolation
PXI‑8432/4 - OTP2-Modul-Nr196
-
The PXI‑8432/4 module is a high-performance, dielectric-proof interface for high-speed communication with RS-232 devices. The module offers data transfers via the high-speed DMA interface, multithreading and multiprocessor support. NI serial ports appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
Pneumatic Subsystem
OTP2-Modul-Nr050
-
With the pneumatic subsystem, a roller terminal, a maintenance unit, a main vent, a pressure reducer and 8 2/3-way vents are installed in the system. The extension of the module can create new possibilities for your test system.
-
Product
CAN/LIN Interfaces - 2 Channel PCIe
OTP2 module no053
LIN Interface
Expand your test system with the high-speed interface of the OTP2 module no053. The extension of the module can create new possibilities for your test system.
-
Product
PCIe Card MX3 Copper Interface
OTP2 module no.183
-
PXI offers the optimal approach to validation and production testing. You can meet timing, synchronization, and throughput requirements across devices. PXI is a robust PC-based platform for measurement and automation systems, supported by software. PXI combines PCI electrical bus characteristics with CompactPCI's modular Eurocard packaging, and then adds special synchronization buses and important software functions.
-
Product
High-Voltage Test Hood
LX-HVE600
-
The bright test room with a ball-bearing cover is designed for high production quantities. Thanks to the easily exchangeable exchangeable plate, retrofitting for testing different products is also a simple task. Product properties: External dimensions (W * D * H) approx. 640 * 716 * 640mm Usable test space (W * D * H) approx. 450 * 500 * 460mm Contacting Installation space approx. 100mm high under removable plate Dielectric strength min 10kV Application area up to 2000m above sea level Pollution degree 1 without condensation Standard conformity EN50191 / EN61010-1 Schmersal safety switch AZM161 with guard locking Lid is supported by ball bearings for high number of cycles, the bearings can be easily exchanged for servicing Optionally available, Not included in the price: - Red / green signal light - Mobile substructure trolley with 19 "
-
Product
Development
-
If possible we use standard market instruments and components. However not every task can be solved technically and economically reasonable. That is when our development department comes to place. Our colleagues already developed many approaches from little, practicable assemblies up to holistic measurement features. These solutions are customer oriented and together with a special firmware this is often a useful solution.
-
Product
2-in-1 High-Voltage Test Hood
LX-HVE900EC
-
The test cells are made of stable, highly insulating plastic and are closed by a swiveling, transparent cover. The built-in safety switch is used to lock the hood and release the high-voltage sources. This ensures that no high voltage is active when the door is open. There is a generously dimensioned wiring space in the floor of the test cage. An interchangeable adapter plate in the test cell - optionally with an interchangeable interface or an interchangeable adapter cassette - allows quick adaptation to different types of test items. Prepared openings enable connectors and other common interfaces or cable bushings to be easily attached. The hood is opened and closed almost effortlessly thanks to precisely coordinated gas springs.
-
Product
DUT Matrix 32 DUT Matrix Channels
40-530-021
-
The 40-530-021 is a high density 32x8 1 pole reed relay matrix. Typical applications are signal routing in functional ATE and data acquisition systems. It consists of highly reliable sputtered ruthenium reed relays that offer >10e9 switching cycles to ensure maximum switching reliability with a long service life and stable contact resistance. Larger arrays can be built by daisy-chaining the common signals from multiple PXI modules
-
Product
Industrial Automation Solutions
-
LXinstruments FCT systems for industrial electronics assemblies are particularly suited for applications with a large variant diversity for medium volume sizes. They are used for testing utility electronics as well as for drive control and grid management systems. We have also implemented systems for functional test, repair and calibration of decentralized PLC I/O assemblies.Since early failures in the field often lead to enormous costs, we not only provide functional test systems, but also burn-in systems for simultaneous testing of many assemblies in a climate chamber. Due to the modular structure of our software, it is possible to establish a logical separation between the definition of the climatic profile to be executed and the actual test sequence, during which the different electrical tests are processed. Connections to HALT/HASS systems can also be established without problems.