Filter Results By:
Products
Applications
Manufacturers
Reactors
-
product
Microwave Cables
Silicon Dioxide cable is a high stability cable at high temperatures and high frequencies. Because of thishigh stability silicon dioxide cables are currently used in nuclear reactors, decoy boxes, radars, satellites,aircraft and sophisticated missile applications. Measure Tech's Silicon Dioxide cable assemblies are excellentfor operation in extreme environment conditions where stability is crucial. Measure Tech's Silicon Dioxidecable is currently used by Lockheed Martin in their JASSM missiles. Measure Tech currently has 100% on timecdelivery for the Silicon Dioxide Cables delivered to Lockheed Martin.
-
product
Automated Breakthrough Analyzer
ABR
The ABR is a dedicated breakthrough analyzer with fully programmable operation including control of total pressure, flow rate, composition and temperature. Samples are loaded into interchangeable reactor beds and dried in-situ with purge gas or vacuum at elevated temperature. Reactive gas mixtures are then flowed through the bed, and the downstream composition determined in real-time with an integrated mass spectrometer.
-
product
Air Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
Iron Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
Current Differential Relay
SEL-587
Schweitzer Engineering Laboratories, Inc.
The SEL-587 Current Differential/Overcurrent Relay provides protection for any two-input apparatus, such as transformers, motors, generators, and reactors. Apply it for differential and overcurrent protection and use event reports for quick post-event analysis.
-
product
Air Core Test Lab Reactors
Test Laboratory Reactors are designed for high voltage and high power test laboratories. They are designed to withstand the most extreme electrical service conditions during test periods. Design techniques are implemented in accordance with the most demanding service conditions. These reactors are used for various purposes in test laboratories such as current limiting and synthetic testing of circuit breakers, capacitor testing, artificial line simulation etc.
-
product
LV Iron Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Condenser for Harmonic Protection
FMLF 7%
Lifasa - International Capacitors, SA
These LIFASA capacitors are designed to be connected in series with INR or INA reactors, and thus form a harmonic filter tuned to a frequency of 189 Hz (lower than the first harmonic present in the network). The nominal powers of the filters indicated in the table are obtained by being connected to the reactors.
-
product
Reduced Voltage Motor Starting Panels by Reactors
A method to limit motor starting current is a series reactor. Iron core or air core reactors can be used for starting purposes. If an air core is used for the series reactor then a very efficient and reliable soft starter can be designed which is more suitable for high MW ratings of synchronous/induction motors at MV levels. The reactors are designed with taps.
-
product
Microwave Synthesis & Synthetic Chemistry
All of Anton Paar’s powerful synthesis reactors – the Monowave series and Multiwave 5000 SOLV – deliver outstanding performance. From smallest quantities to gram-scale library generation and kilogram batch processing, you can be sure to find the right solution for your synthesis application. Whichever choice you make for your laboratory, the systems’ intuitive software always guarantees precise control of your reaction parameters.
-
product
Shunt Reactors
ENTES Shunt Reactors are high quality devices which are designed to meet the inductive load demands.
-
product
Air Core Shunt Reactors
Shunt Reactors act as absorbers of reactive power to increase energy efficiency of the power system. Shunt Reactors are inductors that are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. The shunt reactors provide inductive compensation.
-
product
Highly Inductive Resistance Meter
MR 8050
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
product
Air Core Electric Arc Furnace Reactors
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
product
Neutron Activation Analysis
Neutron Activation Analysis (NAA) is one of the most sensitive analytical techniques used for multi-element analysis available today. The NAA procedure is capable of providing both quantitative and qualitative results for individual elements, with sensitivities that can be superior to those possible by any other analytical technique. Elemental Analysis Incorporated (EAI), as an innovator in the development and application of radio-nuclear chemistry analytical techniques, now offers its clients the ability to analyze some 75 individual elements (including certain organic elements) by NAA at trace and ultra-trace concentrations. Moreover, by developing scientific liaisons with selected nuclear reactor sites in North America, EAI is able to offer customers the expertise and capabilities of the premier scientists and research facilities available today. Combined with EAI’s tradition of excellence in customer service and technical assistance, EAI is uniquely positioned to assist clients with timely, cost-effective, and reliable trace element analysis for almost every conceivable field of industry or scientific research.
-
product
Shock Reactance
ICR260 330
Lifasa - International Capacitors, SA
Shock reactors are necessary to limit the transient currents that occur in the connection of the capacitors.
-
product
Capacitors And Reactors, LV
Wide range of cylindrical and prismatic capacitors for power factor correction in 50 or 60 Hz networks. Models with Heavy Duty system to ensure enhanced performance in extreme environments. Reactors are required to protect capacitors in installations with a high presence of harmonics, maintaining their characteristics and useful life without affecting their operation.
-
product
Neutron Flux Monitoring Systems
To monitor reactor core neutron flux and provide indication during all modes of reactor operation, and to provide trip signals to the Reactor Protection System (RPS) and the Reactor Manual Control System (RMCS).
-
product
Reactor Instrumentation & Control
Capturing the full potential of nuclear power. Our ultra-precise instruments support the safe, optimized operations of nuclear power plants.
-
product
Air Core Smoothing Reactors
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems.
-
product
Air Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Surge Arrester Testing
Weshine Electric Manufacturing Co., Ltd
This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.
-
product
HV AC Voltage Test Systems
Fivestar HV Testing Equipment Co., Ltd.
FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.
-
product
Load Cells & Mounting Kits
Load cells are commonly used to measure weight in an industrial environment. They can be installed on hoppers, reactors, etc., to control their weight capacity, which is often of critical importance for an industrial process.
-
product
Mineral Insulated Cables
We have world-class manufacturing plant for producing wide range of Mineral insulated (MI Cable), metal-sheathed cable. The applications of MI Cable are many such as blast furnace, atomic research, nuclear reactors, Kilns and many more. We provide standard as well as custom-built cables as per the customer need/ application requirement. We have very flexible lines so always ready to meet the demand.
-
product
LV Iron Core Motor Starting Reactors
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
product
NanoSpectralyzer
NS1
ANF offers the NS1 NanoSpectralyzer®, a unique automated fluorimetric analyzer based on the most advanced research in nanotube spectroscopy. This patent-pending instrument combines a specialized optical system with custom software to enable efficient, turn-key analyses of bulk SWNT samples. The NS1 NanoSpectralyzer is valuable for tuning the process conditions in SWNT growth reactors, for quality control, for guiding nanotube sorting and separation methods, and for a wide range of research applications that require detailed compositional data on a rapid time scale.
-
product
Coriolis Mass Flowmeters
CMF
Applicable Fluids: Gases Slurries Liquids. Typical Applications: Custody transfer Reactor feed ratio Density measurement Batch control.
-
product
Protein Sequencer
PPSQ-51A/53A
The PPSQ is an instrument for determining the amino acid sequences of proteins and peptides, which combines an Edman reaction section with a high performance liquid chromatograph (HPLC). There are 2 types: the PPSQ-51A, which is equipped with one reactor, and the PPSQ-53A, which is equipped with three reactors. On the PPSQ-53A, the continuous analysis of the amino acid sequences of multiple samples can be performed one after another. In the Edman reaction section, amino acids are cleaved in order from the N-terminal of a protein by repeatedly performing Edman degradation, and are derivatized. As a result, stable PTH-amino acids are produced. The PTH-amino acids are injected online into the HPLC, and analysis is performed. The HPLC data is saved on the PC, and data processing software is used to process the chromatograms. Then, amino acid sequence estimation software is used to identify the amino acids and estimate the sequences.
-
product
Air Core Harmonic Filter Reactors
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.





























