Product
Calibrators
-
Is a device used to adjust an instrument accuracy, often associated with a specific application.
-
Product
Acoustic Emission System
Pocket AE-2
-
The Pocket AE-2 is a high performance, computerized, dual-channel Acoustic Emission (AE) system which is packed in a robust, portable handheld unit optimal for field use. The Pocket AE-2 offers all the performance, capabilities and features of larger, more expensive MISTRAS’ AE system (wide bandwidth, speed, AE features, sampling rates, waveform processing, audible AE) in a compact, battery-operated package.
-
Product
Calibration Services
-
OMEGA offers a broad range of calibration services, with primary and secondary NIST traceable standards for calibrating temperature, infrared humidity, pressure, flow, and force products.
-
Product
ReCalibration and Post Calibration Software
SI58
-
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
Product
Automatic Calibration Module
ACM4509
-
ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Frequency Calibrator
VCH-313
-
The frequency calibrator VCH-313 is designed to determine the frequency error and calibrate frequency standards of various types based on the signals of the NSC SNS GLONASS/GPS .
-
Product
Monitor Calibrator
hueyPRO
-
It's all about the color. Color in your photos, color in your designs, color online and more importantly, color on your display. World's first built-in ambient light sensor enables consistency never seen before in any lighting condition.
-
Product
NIST Calibration for D620-A
D620-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Volume Calibration
-
Trescal provides full Volume Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Volume Calibration services can be delivered at your site or at our lab. Accreditations for our volume calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Air Pollution Multigas Calibrator
APMC-370
-
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
Humidity Calibration
-
Trescal provides full Humidity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Humidity Calibration services can be delivered at your site or at our lab. Accreditations for our humidity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
TOFD Method of Acoustic Control
-
Time-of-flight diffraction method of acoustic control is a software and hardware suite used for material strength testing based on TOFD method of acoustic control.
-
Product
Digital Light Meter, Calibrated
93-172-C
-
Measures incandescent, fluorescent, metal halide, high-pressure sodium and halogen lampoutput. Color and cosine-corrected for enhanced accuracy. Measures up to 50,000 lux. Peak and data hold means no lost measurements. Accessories included: (1) 9V battery and carrying case. Lifetime Limited Warranty.
-
Product
Portable Calibration System
HD9120
-
HD9120 is an acoustic calibrator that, in accordance with the Circular Prot. RU 34143 of 02 December 2011, allows qualified technicians to perform calibrations of sound level meters for comparison with a reference sound level meter.
-
Product
Acoustic Transducer
RESON TC 3021
-
The TC 3021 is our entry-level, universal 2MHz transducer and is ideal for high precision sound velocity measurements over short distances.
-
Product
Phase Noise Generator / Calibrator
PNG-A
-
Noise eXtended Technologies S.A.S.
The PNG-A is a high precision generator used in Test and Measurement instruments calibration. It is a Signal Generator with precisely computed phase and amplitude noise characteristics. With its wide frequency offset range, 1Hz to 1 MHz offset, and its programmable Phase and Amplitude noise in real time, this is the ideal standard to calibrate phase noise analyzers, Signal Source Analyzers and Spectrum Analyzers.
-
Product
Calibration Kit
N612
-
*N612 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
OTDR Training & Calibration Solution
-
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
Product
Acoustic Transducer
RESON TC 1037
-
Originally designed for underwater telephone systems, the TC 1037 is a rugged directional transducer ideal for operating at low frequencies.
-
Product
Portable Calibrator
MC141
-
Voltage range from 0 to 750 V DC/AC with uncertainty 0.01% Current range from 0 to 2 A DC/AC with uncertainty 0.02 % Calibrated sinusoidal output signal DC - 1kHz. Set standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %. TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC
-
Product
Portable Calibrators
Trig-Tek™ 41P & 45EMD
-
Portable Calibrator is a hand-held signal generator that provides accurate frequency and level in mV and pC
-
Product
IR Calibration Instruments
-
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
Product
Current Probe Calibrator
KSZ
-
PMK Mess- und Kommunikationstechnik GmbH
Since Current Probes are often exposed to hard working conditions, a performance check is recommendedbefore every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 1000 A with an accuracy better 1%. They qualify for calibration and adjustment of Current Probes.
-
Product
Lens Calibration
SpyderLENSCAL
-
A fast, reliable method of measuring and adjusting the focus performance on your camera and lens combinations.
-
Product
Medical Device Calibration
-
Trescal provides full Medical Device Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Medical Device Calibration services can be delivered at your site or at our lab. Accreditations for our medical device calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.