Data Acquisition Systems
sense, log and store information. Also known as: DAS
See Also: Data Acquisition, PCI Data Acquisition, DAQ
-
Product
PXI Multiplexer Dual 24 Ch 1 Pole
40-632-021-D/24/1
Multiplexer Module
This series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole, 4-pole and 1-pole screened.
-
Product
PXI 24x4 Matrix, 1 Pole Screened
40-513-021-S
Matrix Switch Module
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
Product
PXI High Density Mux 5 Channel 16 Pole
40-670A-021-5/16
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected.In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI Very High Density Multiplexer, 99-Channel, 2-Pole
40-675A-002-99/2
Multiplexer Module
The 40-675A-002-99/2 is a 99-channel, 2-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
Product
Software for Recordkeeping Reporting
RegPerfect
-
Data management is vital to your company's bottom line and mission critical environmental compliance goals. Today's environmental professionals must learn to do more with less when faced with budget constraints, rising operating costs, and staff reductions. TML helps environmental professionals around the world meet these challenges by offering RegPerfect Software.The Teledyne Monitor Labs RegPerfect® software system is a state of the art Data Acquisition Handling and Reporting Sytem. RegPerfect® is the culmination of more than 40 years of experience in the data acquisition system business. The software is designed to comply with the data collection, quality assurance, and reporting requirements of federal and local regulatory agencies. Operating in real time, this rugged platform provides the visibility, connectivity and securityfor all of your environmental and operational needs related to the performance of your Continuous Emission Monitoring (CEM) System. For the most recent updates to the software, please visit the Product Status page.
-
Product
PXI 64x4 Matrix Module, 2-Pole, 2A, 60W
40-583-001
Matrix Switch Module
The 40-583 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 64x4 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
Product
PXI High Density Multiplexer, 20-Bank, 8-Channel, 1-Pole
40-615A-001
Multiplexer Module
The 40-615A-001 is a 20-bank, 8-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
Configurable Relay Matrix Module
DP-cPCI-4341
-
DP-cPCI-4341 is a Hot-Swappable Configurable Relay Matrix Module. The relays can be operated separately or all at once. The Form A relays can be used to switch voltage signals upto 200V DC. The inputs and outputs are brought out to the fascia for high flexibility. Use of rugged connectors for field terminations ensures long-term reliability. Applications of the module include automatic test equipment, continuity testing, audio telephone line switching and data acquisition system.
-
Product
PXI 2A Multiplexer, 8-Bank, 4-Channel 4-Pole
40-614-005
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
Software
DASYLAB BASIC
-
Dasylab Basic software for THERMES-USB Temperature Data Acquisition System provides all the necessary functions to display and store temperature data in digital and graphical formats in real time. Users may customize the display to suit their particular application. The Dasylab Basic also provides additional features for data manipulation and statistical analysis. Dasylab basic is required if using multiple THERMES systems.
-
Product
PXI High Density Multiplexer, 4-Bank, 16-Channel, 1-Pole, Screened
40-610A-014
Multiplexer Module
The 40-610A-014 is a screened 4-bank, 16-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI High Density Mux 10 Channel 8 Pole
40-670A-021-10/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI Single 44x4 Matrix, 2 Pole Switching
40-523-022
Matrix Switch Module
Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
Product
Amplifier-per-channel Multiplexed System
System 472
-
The NEFF System 472 (S472) DAS is a complete moderate-speed DAS for use in computer-based applications. The S472 is designed primarily for computer automated data acquisition in test facilities, laboratories and industrial plants or wherever a moderate-speed DAS is required.
-
Product
PXI MUX 4 Bank 0f 16 Channel 1 Pole
40-610-021-4/16/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Single 32x4 1-Pole High-Density PXI Matrix Module
40-520-401
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
High Temperature, Low Strain Capacitive Extensometers (1200 C or 1600 C)
Model 3648
-
Jinan Testing Equipment IE Corporation
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
-
Product
PXI 2A Multiplexer, 2-Bank, 64-Channel 1-Pole
40-614-010
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
Multi-Channel Data Acquisition System
PI-3105
-
This highly flexible system is designed to test a wide variety of imaging devices, from low-noise astronomy and medical devices, to military and machine-vision devices with GB/sec data rates.
-
Product
Temperature Data Acquistion
THERMES-USB RF
-
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.
-
Product
PXI 2 Banks of 80 Channel 1 Pole MUX
40-615-022-2/80/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration. Connections are made via a front panel 200-pin connector.
-
Product
Contactless Laser Extensometers
-
Jinan Testing Equipment IE Corporation
Model LE-05 and LE-15 extensometers measure strain optically, without contacting the specimen, using laser diode technology. The extensometers are self-contained and portable. They may be interfaced with a variety of testing machines and data acquisition systems using the ±10V analog output or bi-directional RS-232 serial port. Operation may be local or remote. A digital display is included. The scanning beam is always perpendicular to the specimen, unlike most laser extensometers. This eliminates errors when viewing through windows in chambers. It also minimizes sensitivity to the distance between the extensometer and the sample. Because the unit measures reflected light, no receiver is required behind the sample.
-
Product
PXI High Density Screened Mux 49 Ch 2 Pole
40-670A-021-S-49/2
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected.In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI MUX 4 Banks of 16 Channel 2 Pole
40-610-022-4/16/2
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI Multiplexer, Single 24-Channel, 2-Pole
40-632A-021-24/2
Multiplexer Module
The 40-632A-021-24/2 is a single 24-channel, 2-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXIe Very High Density Multiplexer, 2A, 79-Channel, 2-Pole, Multiple Channel Mode
42-611B-002-M
Multiplexer Module
The 40-611B-002 (PXI) and 42-611B-002 (PXIe) modules are 79-Channel 2-Pole multiplexers. A 158-Channel 1-Pole configuration is also available. They use high quality electro-mechanical signal relays allowing switching up to 2 A and voltage up to 300 VDC/240 VAC. They are suitable for signal routing in high channel count ATE and data acquisition systems. Connections are made via a front panel 160-pin DIN 41612 connector.
-
Product
Portable Data Acquisition System
TraNET PPC
-
The portable Elsys Data Acquisition Instrument and Transient Recorder TraNET PPC is a high-precision instrument suitable for harsh environments and mission critical applications. It is a very compact, all in one data acquisition solution with a high channel density. The TraNET PPC was specifically designed for flexible portable usage to capture multiple channels simultaneously in applications such as ballistics, explosive tests or acoustic emission.
-
Product
PXIe Very High Density Multiplexer, 2A, 79-Channel, 2-Pole, Single Channel Mode
42-611B-002
Multiplexer Module
The 40-611B-002 (PXI) and 42-611B-002 (PXIe) modules are 79-Channel 2-Pole multiplexers. A 158-Channel 1-Pole configuration is also available.They use high quality electro-mechanical signal relays allowing switching up to 2 A and voltage up to 300 VDC/240 VAC. They are suitable for signal routing in high channel count ATE and data acquisition systems. Connections are made via a front panel 160-pin DIN 41612 connector.
-
Product
Antennas
-
Our broad portfolio of antennas includes products designed for cellular, broadcast, navigation, RFID, IoT, DAS, mmWave, and more. Our antennas are available in standard and custom designs and engineered for use in cars, heavy-transport vehicles including rail, and a wide variety of personal electronics, including mobile device and wearable technology. Our antennas offer high-quality transmission for a wide variety of frequencies including, but not limited to Bluetooth, WLAN, and ZigBee. We manufacture our antennas in facilities worldwide, which include testing capabilities in near and far field patterns, scattering parameters, SAR, vibration, humidity, temperature shock, salt fog, throughput, and acoustic. We also manufacture antenna assemblies.
-
Product
Isolated Hall Effect Current Sensors
-
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.