Current Probes
measure AC or AC-DC amperage without contacting conductors.
See Also: Current Sensors
-
Product
Current Probes
-
Tektronix current probe solutions offer:*The broadest range of AC/DC and AC-only current probes*Measurement accuracy from uAs to 2000 A*Best-in-class bandwidth up to 120 MHz*Best-in-class current clamp sensitivity down to 1 mA*The only products with 3rd Party Safety Certification (UL, CSA, ETL)*The only products with bare wire voltage ratings*Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling
-
Product
Current Probes
-
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
Product
High Current Probes for EV Battery Packs
High Current Probe
Up to 500Amps - customized connections - battery pack charging.
-
Product
Current Probes
-
Current probes allow you to measure DC or AC current. Yokogawa's selection of current probes allow measurements ranges up to 500 ARMS and bandwidths up to 100MHz.
-
Product
T3RC Rogowski Coil Current Probes
T3RC Series
-
Teledyne Test Tools Rogowski Current probes offer a broad range of products covering a wide frequency span and current measurement ranges for maximum application coverage whilst being easy to use in difficult to reach parts of the circuit.
-
Product
Current Probes | Current Sensors
-
Sensitivity of Conventional Probes Deliver Precise Measurement of Low Current Waveforms from 1 mA. High-precision Current Sensors, DC to 4 MHz, DC to 20 kHz, up to 50 kHz and load current sensors,
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
High Current Probe
100 – 187 mil (2.54 – 4.75 mm)
-
Product
Brute Hight Current Probes
P4301
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Current Probes
-
Innovative DC to 5MHz "positional" current probe capable of measuring currents in PCB tracks, component legs etc. without the need to break the connection or surround the conductor.
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Rogowski AC Current Probe,30 MHz, 600 A
N7041A
High Current Probe
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
AC/DC Flexible Leakage/Line Current Probe
FAD-100
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Long Time Record of Measurement by Input Power Supply・Detection of Both AC Current and DC Current At Once・Detection of Small DC current Inside Large AC Current・Freely Bending with Flexible Clamp Sensor of Inside Diameter 200mm・Useful for difficult Access Locations with Wide Ranges up to AC/DC 1000A
-
Product
Rogowski AC Current Probe
RCP500
-
Shenzhen Micsig Instruments Co., Ltd.
Adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; The RCP500 measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise. Directly powered by Micsig UPI interface, realise auto scaling setup,
-
Product
1000 Amp High Accuracy Current Probe
HA1000
-
The HA1000 is our most accurate current probe. The HA1000 clamp-on current probe measures from 1 to 1000 amps AC.
-
Product
AC Current Probe 1 mV/A, 6,000A, 0.055 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m cable, 300mm coil
T3RC6000-LF
-
AC Current Probe 1 mV/A, 6,000A, 0.055 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m cable, 300mm coil.
-
Product
AC/DC Current Probe
CP 30
-
The CP 30 current probe has been designed for use with multimeters respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
Product
Current Probe With Hall Effect Technology
CP 35
-
The CP 35 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
Product
Complete Power Analysis System
PK3564-PRO
-
PK3564-PRO complete Power Analysis System includes PS3550 Power Analyzer, AC charger, Quick-Start manual, deluxe voltage leads, four eFX6000 flexible current probes, SD memory card, CAS3 hard-shell carrying case, PSM-A Software, Mini Line-to-DC Converter, Bluetooth Adapter, USB Communications Cable, and 1-year deluxe warranty.
-
Product
DC/AC High Current Probe
698
-
Unit is designed for use with digital multimeters,lab scopes or graphing meters. With 1000 Amp capabiltiy, this instrument can be used to test starting and charging systems. It can even be used to test relative compression when used with your lab scope or graphing meter.
-
Product
Clamp Meters
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Combine meter and current probe into integrated instrument.
-
Product
AC/DC High Sensitivity Clamp-On Current Probe
N7026A
Oscilloscope Probe
The Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30 Arms or non-continuous 40 Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Current Probe
DCFlex
-
Power Electronic Measurments Ltd
The DCflex is an easy to use, low cost, thin and clip-around DC current probe. It is suitable for measuring large DC currents of >2kA. The DCflex takes a single shot measurement of the DC current with a typical accuracy of ±1%. It is important to understand that the DCflex does not provide a continuous measurement of DC current.
-
Product
High Voltage Non-Contact Current Probe
P02-0802
-
The TESCO High Voltage Non-Contact Current Probe (Catalog No. P02-802) was developed using current sensor technology. It is a two-piece, True RMS ammeter with a fiber optic link between the high voltage sensor and the readout at ground potential. The sensor is mounted on a hotstick and slipped over a high voltage line.
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
50A, 50 MHz CURRENT PROBE, BNC, AC/DC, 50A rms, 75A Peak Pulse
T3CP50-50
-
50A, 50 MHz CURRENT PROBE, BNC, AC/DC, 50A rms, 75A Peak Pulse.
-
Product
Fixed Aperture RF Current Monitoring Probe
TBCP1-200
-
The TBCP1-200 is a fixed aperture RF current monitoring probe.The probe has a 3dB bandwidth of approximately 200 MHz. The aperture of the RF current monitoring probe is 25 mm. Its transfer impedance is > 14 dB Ohm in the range from 40 kHz to 200 MHz.