Fuel Cell Stack
-
Product
Battery Cell Insulation Tester
Chroma 11210
-
Chroma Systems Solutions, Inc.
Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.
-
Product
Power Module Test Cells
-
SPEA’s Power Module Test Cells are the complete industrial equipment oriented to the production test requirements of IGBT semiconductor power modules for consumer, transportation, energy production, industrial applications.SPEA’s Power Module Test Cells provide a turnkey solution for the automated handling, contacting and testing of these products, with the capability to force and measure the very high current (up to 1000 A) and voltage (up to 2500 V) values required for a complete, reliable test.
-
Product
Portable Fuel Dilution Meter
FDM 6000
-
The FDM 6000 is a portable, battery operated fuel dilution meter that determines the concentration of fuel dilution present in an oil sample within a matter of minutes. The FDM 6000 uses a unique patent pending fang design to pierce the cap of a disposable sample vial and draws in the headspace from the vial. The headspace flows over a SAW (Surface Acoustic Wave) sensor which reacts specifically to the presence of fuel vapor with a detection range of 0 – 15%. It can detect diesel, gasoline or jet fuel in engine oil. It conforms to ASTM D8004 - "Standard Test Method for Fuel Dilution of In-Service Lubricants Using Surface Acoustic Wave Sensing"
-
Product
CELL TESTER
SPOTLIGHT
-
SpotLIGHT was designed to minimize maintenance and to significantly reduce downtime. The lifecycle of its contacting system is longer than that of standard systems currently available on the market, thus substantially reducing TCO.
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
Cell Solar Simulator
QuickSun® 130E
-
QuickSun 130E exceeds the ordinary Class A criterions of IEC904-9 ed. 2 with clear margin providing enhanced IV characteristics accuracy. The applicable test methods and procedures are inspected by SGS Fimko Ltd in order to guarantee the compliance and traceability not only with the above standard but also with IEC904-1 ed. 2 which specifies the IV measurement conditions.
-
Product
Stack Usage Analysis
StackAnalyzer
-
AbsInt Angewandte Informatik GmbH
StackAnalyzer automatically determines the worst-case stack usage of the tasks in your application. The analysis results are shown as annotations in the call graph and control flow graph
-
Product
PV Reference Cells
-
Our silicon-based solar irradiance sensors (Si-Sensors) measure the irradiance intensity on your photovoltaic system with utmost precision.
-
Product
Comprehensive Fuel Injection Pressure Test Kit
38000
-
A complete, master fuel injection pressure tester for cars and trucks.Tests gasoline fuel injection pressure systems on virtual all domestic and imported cars and trucks.For multi-port, throttle body and C.I.S. K-Jetronic fuel Injection Systems.Supplied with complete instructions in a durable, plastic molded storage case.
-
Product
Load Cells
-
Honeywell Industrial Automation
Honeywell Sensotec manufactures a wide range of tension, compression, and universal measurement load cells. These load cells are manufactured as standard, modified standard, and custom sensors to provide fast delivery. Many units can ship from our extensive stocking program within 24 hours.
-
Product
Water Filler for Nickel-Cadmium Cells
MasterFiller
-
The MasterFiller is an instrument designed to deliver measured quantities of distilled water as required in the service of Aircraft Nickel-Cadmium batteries.· The MasterFiller consists of a microprocessor controlled pump with a level sensing probe, a keypad and display and an external 12VDC power supply (or optional battery).· The MasterFiller is part of a system comprising Intelligent Charger-Analyzers and Software for Battery Data Acquisition and Analysis, designed to improve the accuracy and efficiency of the process of testing batteries for airworthiness certification.
-
Product
Load cell simulator
PC2M
-
PC2M signal calibrator has been realised to perform periodicalchecks and calibrations on indicators with a 2mV/V input anda 4 or 6 wires systems. Provided with a main switch with 6 selectable steps, it allows to control the linearity on both positive and negative field. Internally, the 350W full bridge unbalancing, is generated by high stability passive resistances (1 ppm/C).
-
Product
Load Cells
-
Instron is the only testing system manufacturer that designs and builds its own load cells, ensuring exceptional accuracy, stiffness, and alignment across a wide measurement range. Produced at Instron’s High Wycombe, UK facility, each load cell is temperature-compensated and calibrated to international standards for outstanding repeatability. Backed by the largest commercial deadweight stack in the U.S., Instron’s calibration process delivers precision that often exceeds industry requirements—providing reliable, traceable performance for even the most demanding materials testing applications.
-
Product
Advanced Diagnostic Load Cell Tester
LCT-U
-
The Advanced Diagnostic Load Cell Tester Model LCT-U is a stand-alone hand-held device specially designed for fast, comprehensive troubleshooting of strain gauge load cells. The LCT-U can quickly diagnose problems with all common types of load cell available today, including 6-wire load cells (with sense wires).
-
Product
Large Telemetry Compressive Load Cell
TC-3.0-LG
-
DLM’s Telemetry Compressive Load Cells can be used independently or in combination as part of weighing platforms.They range from 100t to 300t and manufactured using high grade stainless steel, making these load cells particularly suited to rugged environments and the hire industry. Bespoke size compressive load cells can be designed upon request. Some applications include: tank weighing, hydraulic lifting operations, vessel weighing and certification.
-
Product
Fuel Moisture and Fuel Temperature Sensors
-
Fuel moisture and fuel temperature sensors emulate and measure the moisture content and temperature of similarly sized twigs on the forest floor. The sensors are typically used as part of larger systems, such as fire weather stations with dataloggers and telemetry capability, to remotely assess changing fuel conditions and potential fire hazards.
-
Product
Spectroelectrochemical Flow Cell
SEC-2F
-
Using the spectroelectrochemical flow cell, it is possible to have a different optical path length changing the gasket. We offer, as an optional item, a silicon and Teflon gasket with a 100, 250 and 500 m of the thickness. SEC-2F Spectroelectrochemical flow cell was designed to fit perfectly in the SEC2000 Spectrometer, and it eliminated the use of the optical fiber to connect the Spectrometer to the SEC-2F. Even for another brand of the spectrometer, you can connect the SEC-2F using the collimating lens and optical fiber.
-
Product
Load Cell Indicator
-
Morehouse Instrument Company Inc.
This indicator can read mV/V and use free, custom Morehouse software to convert the mV/V units to engineering units with coefficient files from ASTM E74 or ISO 376 reports. This meter is often the choice for accredited calibration service providers that want high accuracy and convenience but do not want to break the bank.
-
Product
Test Cell System
qCf FC25/100
-
The quickCONNECTfixture with an active fuel cell area of 25 cm 2 has been an integral part of our product portfolio since 2006. The excellent properties and the patented design of the cellFixture offer enormous advantages in the characterization of cell-internal components for fuel cells and electrolysis.
-
Product
Fuel Flow and Torque Converter
Model 44SM1
-
This self-contained, remotely mountable Second Harmonic Fuel Flow Interface accepts data from a second harmonic fuel flow transmitter then converts this information into a frequency output proportional to fuel flow. In addition, this module will accept signals from a T56 Torque Tranducer and provide a DC voltage proportional to Torque. Typical application is for use with Flight Management and Nav Management Systems. The use of field proven designs and carefully selected components assures high reliability field performance.
-
Product
Voltammetry Cell
VC-4
-
Capable for measuring of 1 - 3 ml of sample volume using electrodes with 6 mm of the diameter. Furnished holder prevents the vial from spilling.
-
Product
COMPRESSION, VACUUM AND FUEL PUMP TESTER COMBO SET
MCVK
-
*Tests compression on all domestic and import cars and trucks with gasoline engines*Compression tester kit includes: 2-1/2" gauge with dual inch/metric readings: 0-300 psi and 0 to 21 kg/cm2, 14mm/18mm solid short adapter, 14mm/18mm long flexible adapter and 14mm long reach adapter*Checks vacuum and fuel pump pressure and locates air leaks in fuel lines, vacuum operated chokes and emission control systems on all domestic and import cars and trucks with gasoline engines
-
Product
Power Meters and Calibration Cells
-
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
Product
Reference Cells For PIV-IV Systems
-
NREL calibrated cell used for calibration transfer.The Abet Technologies solar reference cell is a precision instrument for the determination of solar simulator irradiance levels. The sensor is a mono-crystalline silicon solar cell having an area of2x2cm(4cm).The back of the solar cell is attached to the device in such a way that a good heat transfer to the device housing is guaranteed. Below the solar cell a Pt100 RTD temperature sensor is mounted to allow monitoring of device temperature. The device is not shunted allowing the whole IV-curve to be measured. The solar cell is protected by a high quality fused silica window, assuring spectral sensitivity over a 320 -1100 nm range.
-
Product
Industrial Weighing - Wireless Load Cells
-
A wireless industrial weighing scale system can be advantageous, for instance when running conduit for cable is impossible, or if the cable could be damaged easily. In some cases the wireless interface is more economical than long runs of cable. These systems can be battery operated or hard wired to a power source if available. View our wireless load cell options below.
-
Product
Oxygen-free Voltammetry cell
SVC-3C
-
By using SVC-3C oxygen-free Voltametry cell, researchers can get rid of influence of oxygen in the cell by bubbling nitrogen gas, and also run the experiments at low temperatures.
-
Product
olar Cells and Modules Online Measurement System
PV-LIT
-
The fully automatic PV-LIT testing system offers individual and serial testing options for solar cells and complete solar modules. The modular testing system allows easy integration into existing production lines and can be used in automated serial testing for quality assurance.
-
Product
Solar Simulator for Multijunction Solar Cells
-
For series connected multijunction cells, at a given spectrum (e.g. AM 1.5 or AM 0 for space solar cells), one of the cells will limit the current in the series connection of cells. All solar simulators deviate from the true AM 1.5 spectrum, and they are only classified in wide spectral bands (100nm width). So even for class A or A+ solar simulators, it can easily happen that the bandgaps of the multijunction cells are such distributed that the 'wrong' cell will limit the current, if a solar simulator with fixed spectrum is used. In the 70s and 80s, when these measurements were first developed, intercomparisons showed deviations of cell efficiency in fixed spectrum solar simulators of more than 40%.