Filter Results By:
Products
Applications
Manufacturers
luminaire
-
product
Integrating Spheres
IP-Series
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
product
Physical
This category covers test equipment for verification of resistance to heat, fire, tracking, mechanical stress, endurance, impact, force, torque, dimensional accuracy & similar related parameters as required by national and international safety regulatory agencies. These equipment are used to check Electrical WiringAccessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Many of these test equipment are common to many standards and are essential for routine test purposes.
-
product
Goniophotometers
Instrument Systems Optische Messtechnik GmbH
All goniophotometers are designed as Type C with a horizontal alignment of the optical axis (turning luminaire configuration). Each goniometer sets benchmarks in its class for precision, reliability and handling. If these goniophotometers are combined with a spectroradiometer from Instrument Systems, they are able to determine not only photometric data but also spectral quantities, such as color coordinates, color temperature, and even color rendering index as a function of angle.
-
product
Solar Simulator
Unisim
TS-Space Systems is the first company to pioneer the use of metal halide sources in solar simulators for photovoltaic testing. The high temporal stability and close spectral match combined with the ability to control the output spectrum via multiple separate wavebands means the Unisim solar simulator is the only solar research tool designed for the accurate measurement of multiple junction devices, including the new generation of four junction devices. As with all our Unisim solar simulators, they exceed the ASTM, IEC and JIS international standards for spectral match and temporal instability. Using the latest HMI and halogen luminaire technology, the Unisim solar simulator provides a highly stable area of illumination. The simulators also use cutting edge filter technology in order to provide the best spectral match available for AM0 and AM1.5. Further to this, the spectrum can be achieved via two, three or four separate spectral wavebands which allows a high degree of spectral control for research and development. Product support is very important to us. Training is provided at our premises where customers can take advantage of one-on-one tuition with the instrument designers and learn how to operate and maintain their tools. Extensive support via phone and email for the full lifetime of the instrument is included with every TS-Space Systems product.
-
product
IEC60529 IPX7 Water Immersion Test Chamber
Shenzhen Chuangxin Instruments Co., Ltd.
This device is designed and manufactured accordance with requirements of IEC 60529 and GB4208-2008
IPX7 level. Applied to waterproof test of luminaire and household appliance. -
product
Tumbling Barrel Apparatus
ME-999
Is specially designed and manufactured for use in laboratories involved in testing Appliances, Electrical Accessories, Luminaires and other related Electrotechnical products. It is used to perform the test specified in many standards to determine compliance with safety equirements, particularly mechanical strength of test samples.
-
product
Power Over Ethernet (PoE)
Power over Ethernet (PoE) is a revolutionary technology that enables delivery of power over standard Ethernet infrastructure to facilitate quick and easy installation of WLAN access points, network cameras, IP telephones and other IP-based devices. The proliferation of Ethernet-connected devices such as Pan-Tilt-Zoom (PTZ) security cameras, 802.11ac and 802.11ax access points, LED luminaires and Internet of Things (IoT) appliances has created an unprecedented demand for more power. PoE is the key to efficiently, cost-effectively and reliably power network devices.
-
product
Compact Goniophotometer For Lamp Spread Angle Tester
Shenzhen Chuangxin Instruments Co., Ltd.
LCG-1600 Goniophotometrc System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.
-
product
Safety Test Panel for Luminaire Fixture
SCR ELEKTRONIKS introduces Safety Test Panel for Luminaire with PC Datalogging. The tests are Performed as Prescribed in IS the Panel Carries out different tests one by one and provides indication of the Test results as OK or NOT-OK. It is very useful and handy in line testing on Mass production line as well as type Testing.
-
product
Light Distribution Photometer Goniophotometer
LCG-1600
Shenzhen Chuangxin Instruments Co., Ltd.
LCG-1600 Goniophotometeric System carries out measuring methods of fixed location and rotating luminaires. The measured luminaire is installed on the two-dimension rotating table, using “+” laser to make the luminaire lighting center superposed with the rotating center of rotating table. The mechanical equipment allows turning the tested luminaires around a vertical axis and a horizontal axis. When tested luminaires turn around horizontal axis, the detector which is at the same level with rotating table will measure the intensity of each direction at this surface. When rotating with vertical axis, the detector will measure the intensity at the vertical surface. The vertical and horizontal axis can be rotated continuously at ±180° or 0~360°. According to the measurement requirements, the system can be operated in C-γ coordinates. When getting intensity distribution data, computer will calculate other photometric parameters automatically.
-
product
Goniophotometer
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
product
Goniophotometer For Luminaries Intensity Distribution Curve
LCG-1800
Shenzhen Chuangxin Instruments Co., Ltd.
Mainly used to measure FL etc. When installing luminaires, the lighting center of luminare and the rotating center of rotating table shall be at the same position. In B- coordinates, luminaire axis is superposed with the horizontal axis of rotating table. In A- coordinates, luminaire axis is vertical with the horizontal axis of rotating table.
-
product
Ball Pressure Apparatus
BP-20
Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
Precision Kelvin Holders
MH-4 Series
Integrating Spheres are essential tools for photometricresearch laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary.
-
product
Safety
Test Equipment to verify Safety, Quality and Compliance characteristics of electro-technical products as required by national and international safety regulatory agencies. These equipment are used to check Electrical Wiring Accessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Several of these safety test equipment are common to many standards and are required for routine 100% test purposes to ensure product safety.
-
product
GO-SPEX500 Goniospectroradiometer
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for all kinds of indoor lamps, flood lamps, road lighting lamps and all kinds of light distribution performance test, total luminous flux, luminaire efficiency and electrical parameters (voltage, current, power, power factor) measurement.Test data can be saved as IESNA(*.ies), CIBSE(*.CIB), EULUMDAT(*.LDT), CIE(*.cie), CEN(*.cEN) and other formats, which can be directly used as the input data of international general lighting design software.
-
product
Constant Temperature Integrating Sphere
IS-*MT
According to requirement of IEC standards, the standard test temperature is 25℃, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
Measuring System for Assessment of Optical Radiation Safety
IEC62471
The system is designed especially for the determination of optical radiation hazard exposures specified in IEC62471, such as actinic UV hazard exposure for the skin and eye, near-UV hazard exposure for the eye, retinal blue light hazard exposure, retinal thermal hazard exposure, thermal radiation hazard for eye and skin, for LED products, UV-Lamps, lighting sources, luminaires and etc.
-
product
General Lighting & Luminaire Goniophotometers
Photometric Solutions International Pty Ltd
These are Type C/gamma goniophotometers with wide-ranging applications including luminaires, floodlights, streetlights, LED clusters, emergency lighting, flat panel displays and others. These goniophotometers typically have an angular accuracy of better than 0.1°, which is perfect for LED and luminaire goniophotometry. The control software that comes with each system has advanced functions that make testing easy – even for inexperienced users. Additionally, the report generator and other software utilities that are also supplied make these systems powerful and advanced research and development tools.
-
product
LM-79 Moving Detector Goniophotometer
LSG-5000
Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
-
product
Compression Test Apparatus
CT-20 C
Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat
-
product
HAAS-1200 Accurate Array Spectroradiometer (Advanced Industry Grade)
HAAS-1200
Hangzhou Everfine Photo-E-Info Co., LTD
HAAS-1200 quickly and accurately measures the spectral power distribution in the range of 380nm-1000nm, and achieves the photometric, colorimetric and radiometric parameters of various luminairs and lighting sources according to the requirements of the International Commission on Lighting (CIE) standard publications.
-
product
LT-300A Aging-Life Test System For LED Luminaires
Hangzhou Everfine Photo-E-Info Co., LTD
LT-300A system is widely used for normal /accelerated aging, lumen maintenance measuring, chromaticity shift measuring, lifetime evaluation and temperature characteristic testing for LED luminaires, arrays, and modules. The extrapolation of lifetime by programmable models is also available to estimate the lifetime of LED luminaires.
-
product
IK Level Tester
IK07-10
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
product
LT-500A Aging-Life Test System For LED Luminaires
Hangzhou Everfine Photo-E-Info Co., LTD
LT-500A system is widely used for normal /accelerated aging, lumen maintenance measuring, chromaticity shift measuring, lifetime evaluation and temperature characteristic testing for LED luminaires, arrays, and modules. The extrapolation of lifetime by programmable models is also available to estimate the lifetime of LED luminaires.
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Near Field Moving Detector Goniophotometer
LSG-1900B
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
product
Lighting Reliability
LED/OLED package lifetime is highly dependent on thermal management, and LED lamp performance can be dependent on the luminaire in which it is installed. Lighting reliability test system for LED/OLED Products are widely used for normal /accelerated aging, lumen maintenance measuring, lifetime evaluation and temperature characteristic testing for LED/OLED products including LED package, array, module, OLED module and luminaires.





























