Resistance
that which keeps current from flowing freely.
See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire
-
Product
Passive Probe
PP011-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
PCI High Density Pecision Resistor Card
50-298-131
Programmable Resistor Module
The 50-298-131 is a high density programmable resistor card with 4 channels which can be set between 3Ω and 13.6kΩ with 0.25Ω resolution The 50-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
PXI 5W Programmable Resistor Module, 2-Channel, 2Ω to 6.97kΩ
40-252-030
Programmable Resistor Module
The 40-252-030 is a programmable resistor module with 2 channels which can be set between 2Ω and 6.97kΩ with 0.125Ω resolution The 40-252 range provides a simple solution for applications requiring up to 5W of power handling per channel. The 40-252 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
Product
Wristat Tester
WT 25-4145.26M
-
WT 25-4145.26M Wristat Tester is available to comply with D.O.D. 4145.26 specifications. The WT25-4145.26M Wristat Tester is designed to test the integrity of our WRISTAT in a fast, efficient, and simple manner. All the elements of the WRISTAT – continuity of the strap, integrity of the protective resistor, and satisfactory strap to skin contact – are easily confirmed by pressing the top cover of the WT25-4145.26M. The operator (wearer) is tested for a resistance to ground of greater than 250K ohms and less than1,200,000 ohms. The upper limit notifies you of an unacceptably high resistance value (IE possible loss of effective dissipation) and the lower limit warns of unsafe low resistance (possible risk of electric shock from surrounding motors, live wires etc.). The unit is not switchable.
-
Product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25V-6
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Electrometer / High Resistance Meter, 0.01fA
B2985B
Electrometer
The B2985B Electrometer/High Resistance Meter is the world’s only graphical electrometer that allows you to confidently measures small currents with 0.01 fA (0.01 x 10-15 A) resolution and large resistances of up to 10 PΩ (10 x 1015 Ω). It possesses a 4.3” color LCD with a graphical user interface that provides trend chart and histogram data in addition to numeric information.
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
12.1" XGA Industrial Monitor With Resistive Touchscreen, Direct-VGA, DVI And Wide Operating Temperature
FPM-3121G
Industrial Monitor
12.1" XGA LED backlight LCD with low power consumptionRobust anodized coated aluminum front bezel and stainless steel rear coverSupports wide operating temperaturesIncrease reliability by enhanced 5-wire resistive touch sensorAnti-reflective screen with tempered glassFull enclosure ground isolation protectionSupports VGA/DVI input, dual touch interfaces and two power inputsFront lockable OSD membrane keys with user-defined brightness settingEnergy Star certificationFront panel is IP65 compliantSupports panel, VESA, wall and desktop stand mounting
-
Product
Speed Sensors
-
DHE (Differential Hall Effect) sensors give an output when subjected to a changing magnetic field. The field is set up by a magnet inside the sensor body and changes when ferromagnetic teeth are passed beneath the sensor (no magnets are required in the target). To improve noise resistance, the sensor has two Hall effect elements and only responds to changes in magnetic field strength corresponding to tooth passing frequencies above 15Hz. As each tooth passes the sensor, the digital state of the output changes.
-
Product
PXI 2 Pole 18 way Mux with 2 Pole 18 way sen
40-658-002
Multiplexer Module
This PXI multiplexer combines a 2-pole 18-way power distribution MUX with a second lower power 2-pole 18-way MUX in one convenient single slot PXI module.The module is ideal for power distribution where power and sense signals are required to be connected to an array of devices under test. This multiplexer is also convenient for making 4 wire low resistance measurements by supplying the resistor under test with high current through the power MUX and sensing the voltage drop through the sense MUX.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1T1-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Battery Testing
-
Weshine Electric Manufacturing Co., Ltd
The DC test method is adopted to simulate the actual use of the battery in a real and objective way, which can effectively eliminate the hidden dangers such as deficiency, deficiency and connection failure between batteries while measuring the internal resistance of the battery.
-
Product
Salt Spray Corrosion Test Chamber
CX-Y60L
-
Shenzhen Chuangxin Instruments Co., Ltd.
Laboratory Salt Spray Corrosion Test Chamber for Nss / Acss / Cass Test is used to test the anti-erosion quality of the surface of all materials after the rust-proof of painting, coating, electroplating, anoding and rust-proof of greasing.anti corrosion treatment for a variety of materials, corrosion resistance of their products.
-
Product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Flexible Implantable Microprobe
IT-18EXLONG
-
IT-18EXLONG Flexible Implantable Microprobe with 5 foot lead - Implantable in semi-solids and tissue with 18 gauge needle (supplied). Also for immersion in various solutions and rectal temperatures of small animals. Totally sheathed in chemical resistant Teflon™. Quited rugged. Maximum Temperature 150°C . Isolated. Probe diameter .050" (14 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.3 seconds.
-
Product
PXI Switched Guard Reed Relay Module, 8x 2:1 Multiplexer
40-121-012
Multiplexer Module
The 40-121-012 provides 8x 2:1 multiplexers in a single slot PXI module and designed to provide an isolation resistance in excess of 1013Ω. It has been designed to ensure high isolation resistance through the use of switched guards, making it ideal for low level measurements and semiconductor test.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
15.6" Ubiquitous Touch Computer
UTC-515G
Panel PC
15.6" Ubiquitous Touch Computer with Intel® Pentium® N4200 processor. Low power consumption and fanless design. Built in Intel® Pentium® N4200 processor. 15.6" monitor with 16:9 widescreen display. IP65-rated front panel for water and dust resistance. All in one aluminum extrusion design.
-
Product
Oil Resistivity Test System / Million Meg Ohm Meter (MM1)
OTD-45
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Model : OTD-45OTD-45 is single self contained unit containing oil test cell, high frequency induction heating with temperature controller/sensor; dielectric loss measuring bridge, AC test voltage source, SF6 filled standard capacitor; high resistance meter; DC voltage source and all digital circuits.
-
Product
Pyrometer With Integrated Controller
thermoMETER CS
-
The infrared thermoMETER CS temperature sensors are equipped with a miniature sensor that is particularly suitable for installation in confined spaces. The small size and temperature resistance up to 120°C open up a wide range of applications.
-
Product
PXI/PXIe High Density Precision Resistor Module
42-297A-151
Precision Resistor Module
The 40-297A-151 (PXI) and the 42-297A-151 (PXIe) are 3-channel programmable resistors with a range of 3 Ω to 2.97 MΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
Rain Test Chamber
-
Xi'an LIB Environmental Simulation Industry
Simulates real-world rain exposure to test the waterproofing and weather resistance of products.
-
Product
PXI/PXIe High Density Precision Resistor Module, 18-Channel
40-297A-016
Precision Resistor Module
The 40-297A-016 (PXI) and the 42-297A-016 (PXIe) are 18-channel programmable resistors with a range of 1 Ω to 1.8 kΩ. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
Product
PXI RTD Simulator Module 18-Channel PT1000
40-262-002
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
15.6" Ubiquitous Touch Computer
UTC-515H
Panel PC
15.6" Ubiquitous Touch Computer with Intel® Core™ i3-8145UE processor. Low power and fanless system design. Built-in Intel® Core™ i3-8145UE processor. 15.6" monitor with 16:9 widescreen display. IP65-rated front panel for water and dust resistance.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Data Acquisition Conditioner
D4
-
The Model D4 Data Acquisition Conditioner is a portable, USB-powered precision instrument for use with resistive strain gages and strain gage-based transducers.
-
Product
Thick Film Divider
GBR-391
-
GBR-391 series high-voltage resistive dividers are made in a thick film technology on ceramic substrates (Al2O3 - 96%) with leads for through-hole mounting. Dividers are characterized by very high maximum voltage, and standard voltage division.
-
Product
Wire Mount Testers
-
Is designed to measure and control the DC resistance, electrical capacity, insulation resistance of electrical circuits and check the electrical insulation strength of electrical circuits.
-
Product
Thumpers and Cable Fault Location
-
Cable testing can be broken down to different steps of the process, starting with a time domain reflectometer test to look for an incident signal on the line or, in some high resistance situations, VLF testing. These tests will identify a fault, allowing you to move on to pre-locating it. In some low resistance faults this will occur alongside the identification via the TDR.