Calibration References
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services
-
Product
Automatic Calibration Module
ACM2509
-
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Decade Box, Calibrated W/D & U, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL DU
-
The 72-7270 CAL DU from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Light / Lux Meter, Calibrated, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL
-
The 72-7250 CAL from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
FOCL Reference Signal Modem
VCH-607
-
FOCL reference signal modem VCH-607 is designed to receive and transmit electrical signals with a nominal frequency of 100 MHz through a fiber-optic system and generate electrical signals with a nominal frequency of 5 and 10 MHz, coherent with the input signal. Reception and transmission through the FOCL is provided using a pair of modems: one is configured as a Transmitter and is installed at the end of the FOCL where the signal source is located, the second is configured as a Receiver and is installed at the opposite end of the FOCL.
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-1m
Cable Assembly
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-297 and 50-297 enabling calibration via an external DMM.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Automatic Calibration Function oH Meter
AH-151
-
The pH meter AH-151 with automatic calibration function performs pH measurement by automatically cleaning the electrode with cleaning solution and performing calibration with standard solution, making it possible to drastically reduce maintenance work. In addition, by spraying the calibration solution, the consumption of calibration solution has been reduced. The spray amount of the cleaning solution can also be adjusted according to the condition of contamination, which contributes to cost reductions. With periodic cleaning and calibration, stable and highly reliable pH measurements are possible.
-
Product
Instrumentation Calibration Services
-
We offer a range of instrumentation calibration services for Kemo products in addition to other signal conditioning and sensors. We have many decades of experience in the manufacture, test and calibration of our instruments and those of our competitors. Please refer to the list below for an example of our calibration options, all equipment used within our calibration department is calibrated and traceable to a UKAS accredited National standard:
-
Product
Calibrators
-
Is a device used to adjust an instrument accuracy, often associated with a specific application.
-
Product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL D
-
The 72-7770 CAL D from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
Product
Three Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
Product
Calibration And Verification Instruments
-
The system of automatic calibration and verification consists of a computer of the operator's workplace and a control controller with a calibrator connected to it and a verified device. The device under test can have 4 to 16 working channels with a complicated circuit for connecting different types of signals: voltage, current, thermocouples, thermoresistance. The system allows a change in the set of operating ranges during calibration and calibration. The software development system used the LabVIEW development environment with the Real-Time module.
-
Product
COM-HPC Server Type Size E Reference Development Platform based on Ampere® Altra® SoC
Ampere Altra Developer Platform
Software Development Kit
Backed by a broad Arm® ecosystem with an Ampere® Altra® SoC at its core, using the Arm® Neoverse™ N1 platform, the Ampere Altra Developer Platform provides premium performance from a cloud-to-edge infrastructure, keeps an extremely low thermal envelope, lower TCO, and significantly lower power consumption than x86 designs. It supports the open source EDKII as bootloader with UEFI, so customers can just download a stock AArch64 (arm64) ISO such as Ubuntu and install it through booting a live ISO directly on the target. The same convenience we have become used to by using x86 / amd64 target systems.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm
CK520A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Portable Protection Test Set and Calibrator
CMC 430
-
The CMC 430 is the preferred choice for test engineers in cases where excellent transportability is needed and three currents up to 12.5 A or six voltage outputs are sufficient. Its low weight of just 8.7 kg / 19.2 lbs, and robust design with its edge protection predisposes the device to every outdoor and indoor use.
-
Product
Acoustical Generator (STIPA Reference)
TalkBox
-
The TalkBox is an acoustic signal generator for speech intelligibility measurements in evacuation and announcement systems, as well as for level alignment of teleconference or other audio systems. It allows you to perform a complete end-to-end evaluation of the speech intelligibility STI from the talker’s microphone to the listener’s ears.
-
Product
Signal Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
If you are looking for Signal calibrators that are best in industry, head over to Nagman website immediately. We have a range of signal calibrators, loop calibrators, milliamp calibrators, process meter and more. Depending on the requirement at hand, you can find a signal calibrator that is best suited for your industry. Signal calibrators can be used for calibrating thermocouples, RTD, transmitters, etc. while loop calibrators are used for calibrating controllers, indicators, etc. Nagman’s range of signal calibrators are handy, light weight, portable and durable.
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Field Strength Calibration Probe
-
Beijing KeHuan Century EMC Technology Co,.LTD
Three-axis omnidirectional 100kHz~6GHz light transmission.
-
Product
Oscilloscope, Calibrated, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A CAL
-
The 72-8710A CAL from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides a complete set of trigger modes including edge, pulse, alternate and storage modes including set-up, wave, bitmap. It has a 7 inches wide screen LCD display and supports plug and play USB storage device. Communication with and remote control of computer through the USB device.
-
Product
802.11ad Testbed, Reference Solution
-
Generate and analyze 802.11ad fully coded PHY waveforms for complete component, subsystem, and system performance at baseband, IF, and millimeter-wave. This Reference Solution combines Keysight Technologies software and hardware to provide a flexible testbed for 802.11ad waveform generation and analysis. Software provides the flexibility to generate and analyze 802.11ad waveforms with a wide range of different attributes. Hardware provides the flexibility to support baseband, IF, and millimeter-wave test planes. Create waveform sequences with unique 802.11ad packet structures including Modulation Coding Scheme (MCS), packet length, payload data type, and interpacket gap length, etc.
-
Product
Waveguide Calibration Kits
-
Designed to provide accurate calibration of vector network analyzers (VNAs) that are used for measurements in standard rectangular waveguide from 2.6 to 50 GHz (WR284–WR22).
-
Product
High Precision Angular Positioning, Calibration and Geometry INspection
LabStandard AIR
-
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.The LabStandardAIR has been designed as a “Contact Free” system and eliminates features, which may detract from achieving the optimum rotational performance. The rotating elements are supported on super high precision, air lubricated, hydrostaticbearings and are not subject to disturbances associated with gear drives.
-
Product
PLTS Advanced Calibration
N19305B
-
PLTS N19305B extends the N19301B base product to perform advanced calibration techniques such as Automatic Fixture Removal (AFR)
-
Product
mA Loop Calibrators
-
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
Product
Panel Meter Calibrator
1040C/CU
-
Calibrate panel meters, transducers, circuit breakers and relay units with Model 1040C, a portable, field-ready unit featuring eight key calibration functions.
-
Product
Xytronic Single-Phase Reference Standard +/- 0.04%, +/- 0.02%, +/- 0.01%
RADIAN RX-20, RX-21 and RX-23
-
Radian Research is committed to providing our customers with leading innovative and technologically superior products, while maintaining metrology capability in power and energy measurement that is surpassed by none. Our engineers drew on the expertise and knowledge we acquired for our industry-leading legacy RM (Metronic) and RD (Dytronic) reference standards to develop the RX (Xytronic), the ultimate in power and energy measurement technology perfection.
-
Product
Backflow Test Kit Repair Calibration & Certification
-
Meeting Water Safety regulations and standards has become a primary concern for all industries. Most municipal and state regulators demand that Backflow Prevention Testing be carried out no less than once per year and that testing devices be calibrated and if required, certified regularly.





























