Cable Sheath
test and fault location of a compromised cable covering.
See Also: Cable Fault Locators, Cable Assembly
-
Product
Cable Sheath Fault Location
-
Locating cable sheath faults is one of the last steps in cable testing, occurring after you have identified the existence of a cable fault via the identification procedure based on your specific site variables and the type of system you are working on
-
Product
VLF Testing and Diagnostics Unit
Viola TD
-
Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences
-
Product
Mobile Cable Fault Location System
Syscompact 2000
-
Fault location with Syscompact 2000. The Syscompact 2000 is a multifunctional cable fault location system designed for modular 19" rack technology. The integrated surge and test generator is used for cable and sheath testing as well as for precise location of high-resistive and intermittent faults. The SYSCOMPACT 2000 is preferably used in low- and medium-voltage networks for fault location up to a cable lengths of 65 km. * Fast and reliable * Precise, dependable cable fault location High performance * high voltage unit* Integrated proven cable fault pre-location methods
-
Product
Search Receiver
KMF 1
-
Cable fault location with the BAUR KMF 1. The KMF 1 search receiver is used according to the step voltage method. The cable line is scanned with two measurement probes that can be dismantled during transport. The battery-operated device is also suitable for locating multiple consecutive sheath faults.* Battery mode* Zero point compensation* accurate location of cable sheath faults* battery test
-
Product
Split-box Pipe & Cable Locator
-
Weshine Electric Manufacturing Co., Ltd
Pipe Locator is specially designed to detect pipes, sondes, telecommunication lines buried utilities. This device may detect buried power cables, CATV cables, gas and water pipes, sewer lines, telephone cables, fiber optic cables with sheath, sondes, inspection camera transmitters. The Transmitter emits a signal.
-
Product
Low-Temperature Impact Device
DWC-1
-
This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally
-
Product
Cable Sheath Testing and Fault Location System
Shirla
-
Cable fault location with the BAUR shirla. Shirla the fault location system is used for cable and cable sheath testing as well as for pre-location and pinpointing of cable faults. The pre-location based on the measuring bridge principle according to Murray and Glaser that is designed especially for power cables, also enables pre-location for control and lighting cables. Null balance and evaluation take place automatically.* Cable and cable sheath testing up to 10 kVC* Resistance measurement* Cable and cable sheath fault pre-location with precision measuring bridge* Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation
-
Product
VLF Test System
BAUR PHG 70 portable
-
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
Product
VLF Testing and Diagnostics Unit
Frida TD
-
Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
Product
VLF test system
BAUR PHG 80 portable
-
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
Product
High-Voltage Test and Diagnostics Device
Viola
-
Cable testing and diagnostics with the BAUR viola. The portable and powerful viola high-voltage testing and diagnostics device is used for cable and cable sheath testing of medium-voltage cables up to 35 kV and electrical equipment. Another function is insulation testing on electrical equipment.* High performance and compact* Precise and non-destructive determination of the cable condition* Easy and quick test setup* Automatic testing and diagnostic sequences
-
Product
VLF Testing and Diagnostics Unit
Frida
-
Cable testing and diagnostics with the BAUR frida. The portable and powerful high-voltage testing and diagnostics device is used for cable and cable sheath testing of medium-voltage cables up to 20 kV and electrical equipment. Another function is insulation testing on electrical equipment.* Precise and non-destructive determination of the cable condition* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
Product
Cable Assembly 78-Pin D-Type, Male to Unterminated With Tinned Ends
A078HM5-T-0A200
-
A 78-Pin D-Type to Unterminated cable assembly constructed from 7/0.15 (26AWG) Silver Plated Copper Wire. Screwlocks are provided to secure the cable connector to associated products.
-
Product
Cable Assembly, Receiver, TriPaddle, 36", 78-Pin Female D-Sub
540034010203
-
Cable Assembly, Receiver, TriPaddle, 36", 78-Pin Female D-Sub
-
Product
Cable Assembly, Receiver, 20/26GHz Coaxial, 36", 7 SMA Plugs
540133010253
-
Cable Assembly, Receiver, 20/26GHz Coaxial, 36", 7 SMA Plugs
-
Product
Cable 100-Pin Micro-D Male To Unterminated, With Ferrules, 0.5m 2-56 UNC Screwlocks, Metal Shell
A100SMR-F-9B050
-
100-Pin Micro-D Male to Unterminated Cable Assembly With Ferrules, 0.5m Long With 2-56 UNC Screwlocks and Metal Backshell. Suitable for use with Pickering BRIC Modules.
-
Product
20-Pin GMCT Cable, Female to Unterminated, Cut Ends, 16A, 1m
A020GFR-C-1B100
-
The 16A 20-Pin GMCT cable assembly is constructed from 19/0.41 (14AWG) Copper Wire with PFA 500V insulation. Screwlocks are provided to secure the connector to associated product. The unterminated connections are coded to match the connector pin designation and include crimped on ferrules to ensure the wire strands cannot break when they are terminated.
-
Product
Cable Assembly, ITA, I1 Hybrid 4/4, TriPaddle, High Power, 36", Flying Leads
410128565
-
Cable Assembly, ITA, i1 Hybrid 4/4, TriPaddle, High Power, 36", Flying Leads
-
Product
Cable Assembly 68-Pin Micro-D Female to Unterminated, Cut Ends, 0.5m, Screwlocks
A068SFR-C-6B050
-
The 68-Pin Connector to Unterminated Cable Assy is constructed from 7/36 (28AWG) twisted pair wires with polypropylene insulation. The wires are colour coded to match the connector pin designation. The connector can be secured to the product by 2-56 UNC Screwlocks.
-
Product
Cable Assembly, 50-Pin D-Type, Male to Unterminated With Cut Ends, 2m HV, Exit Towards Pin 1
A050DM5-C-HA200
-
50-Pin D-Type HV Cable assemblies are constructed from 7/0.2 (24 AWG) Tinned Copper Wire with PTFE Type C insulation. The connector assembly can be secured to the mating part by a screwlock. The 50-Pin Female connector options of this product can be directly mated to a corresponding Pickering Interfaces switching product.
-
Product
Cable Assembly, Receiver, TriPaddle, 20", (for NI PXI-2527) with Banana Plugs for a DMM
541122953
-
Cable Assembly, Receiver, TriPaddle, 20", for NI PXI-2527 with Banana Plugs for a DMM
-
Product
Cable Assembly, 50-Pin D-Type, Male to Male, 2m, Exit Away From Pin 1
40-970-050-2m-MM
-
The 50-Pin Cable Assembly is constructed from PFA insulated wire and can be secured to the product by screwlocks. The 50-Pin Female connector option of this cable assembly is suited for direct connection to Pickering Interfaces products.
-
Product
SHB12X-B12X, 73-Pin, Male InfiniBand to 73-Pin, Male InfiniBand, 100 Ohm, Shielded LVDS Cable 2m
192344-02
-
The SHB12X-B12X LVDS Cable connects the 12X InfiniBand connector on PXIe-656x LVDS instruments or some NI 658x LVDS Adapter Modules for FlexRIO with other NI accessories such as the SMA-2164 to break out cable signals for direct access. It is a shielded, 100 ohm cable that is offered in various lengths.
-
Product
Cable Assy 68-Pin SCSI Micro-D M/F 0.5m
40-970A-068-0.5m-MF
-
The 68-Pin SCSI Style Micro-D Cable Assembly is constructed from 7/36 (28AWG) Copper Wire with Polypropylene insulation. Metal Spring Latches are provided to secure the connectors to their associated products.
-
Product
Cable Assembly 68-Pin Micro-D Female to Unterminated, Ferrules, 2m, Screwlocks
A068SFR-F-6B200
-
The 68-Pin Connector to Unterminated Cable Assy is constructed from 7/36 (28AWG) twisted pair wires with polypropylene insulation. The wires are colour coded to match the connector pin designation. The connector can be secured to the product by 2-56 UNC Screwlocks.
-
Product
Cable Assembly 68-Pin Micro-D Male to Unterminated, Tinned Ends
A068SMR-T-5A100
-
The 68-Pin Connector to Unterminated Cable Assy is constructed from 7/36 (28AWG) twisted pair wires with polypropylene insulation. The wires are colour coded to match the connector pin designation. The connector can be secured to the product by a Metal Spring Latch.
-
Product
Cable Assembly, Receiver, 20", QuadraPaddle, 2 60-Pin LFH
540320010140
-
Cable Assembly, Receiver, 20", QuadraPaddle, 2 60-Pin LFH
-
Product
SMA Male to SMA Male Cable, 50 Ohm, 30 cm
781846-01
-
The SMA-SMA Coaxial Cable, sometimes referred to as SMA100, connects measurement and signal devices. NI offers this 50 Ω cable in different lengths.
-
Product
68-Pin VHDCI Cable Assembly, Male to Unterminated With Ferrules, 0.5m
A068VMR-F-6C050
-
The male cable assembly is suited for direct connection to various products using the 68 Way VHDCI connector.
-
Product
Cable Assembly 15-Pin D-Type, Male to Unterminated With Cut Ends, 1m
A015DM5-C-0A100
-
The 15-Pin Connector to Unterminated Cable Assy is constructed from PFA insulated 19/0.18 (21AWG) Tinned Copper Wire. The connector can be secured to the associated product by screwlocks. The unterminated connections are coded to match the connector pin designation. When using this product additional cable strain relief arrangements may be necessary and appropriate electrical safety precautions should be observed.