Cross Correlator
-
Product
Single Shot Third-order Cross- Correlator
Rincon SS
-
Specifically developed for measuring a wide array of output parameters from ultrafast laser systems including: contrast ratio of laser pulses, determining pulse pedestal, pre- and post-pulses, and amplified spontaneous emission in femtosecond systems.
-
Product
Auto-Correlator/Cross-Correlator
FR-103WS
-
The FR-103WS is a dispersion-free Autocorrelator/Crosscorrelator for monitoring the temporal width of ultrashort optical pulses. While providing excellent sensitivity and resolution, the FR-103WS is ideally suited for the measurement of long pulsewidths (up to 200ps).
-
Product
Rapid Scanning Auto-Correlator / Cross-Correlator
FR-103XL
-
The FR-103XL is a dispersion-free Autocorrelator/CrossCorrelator for monitoring the temporal width of ultrashort optical pulses. Offering unsurpassed sensitivity and resolution, it is compact and easy to operate. The FR-103XL is ideally suited for the measurement weak signals in optical telecommunications, as well as pulses from other mode-locked lasers such as Ti-Sapphire.
-
Product
Cross-Correlator Pulse Profiling Systems
Rincon
-
The third order cross-correlator is ideal for looking at the full range of output from amplified femtosecond laser systems. High temporal resolution over a long (close to 1 ns) window shows pulse features that are usually missed, giving the user a detailed and complete picture of the quality and stability of the output pulse parameters of their femtosecond lasersystem.
-
Product
Phase Noise Analyzer
NXA-26
-
This new NXA-26 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 26.5 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range. The NXA-26 combines over 25 years of Phase Noise Measurement Technology with an easy to navigate user interface. System operation requires minimal training that will have you making measurements in minutes.
-
Product
Phase Noise Analyzer
NXA-50
-
This new NXA-50 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 50 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
Phase Noise Analyzer
NXA-6
-
This new NXA-6 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 6 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
Phase Noise Analyzers
-
The phase noise analyzer portfolio from Rohde & Schwarz offers an affordable, mid-range solution with high sensitivity and fast measurements as well as high-end ultra-high-sensitivity solutions with advanced measurements modes. Ideal for phase noise analysis and VCO tests, the industry-leading solutions enable two-path phase noise analysis with real-time cross correlation and fast VCO characterization with built-in low-noise DC sources. Additionally, high-end signal and spectrum analysis can be added into a single box.
-
Product
STEREO PERFORMANCE METER
SPM-1
-
The SPM-1 measures the stereo content present in any left and right audio program material. It measures 0-50 dB separation on live program material by cross correlating the right and left base-band audio information.
-
Product
Collaborative Correlative Microscopy
nanoGPS navYX
-
Correlative microscopy is the combination of multiple modalities performed on the same sample. The results produced emphasize the strengths of each modality while offsetting their individual limitations.nanoGPS navYX™ is an open solution which makes SEM-Raman correlative microscopy seamless regardless of the electron and optical microscopes used. Simply stick the Coordinates Transfer System to the sample!
-
Product
Data Record Adaptor and Correlator
Joiner
-
nTh Network Technologies to Help
Joiner is a data record adaptor and correlator for mobile and core networks management. The ideal partner for big data architectures with data lakes and analytic applications. Distributed as Docker component, it may be orchestrated in line with the network virtualization function concepts.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Cross Hole Energizer P/S
CHE
-
Specially designed for small-scale cross-hole surveys, this compact hammer can be used to generate both P and S waves.The hammer can be downloaded using the steel cable and clamped to the requested depth by a pneumatic clamping system manually controlled by a lever from the surface; simply pushing up the steel cable to execute the first shot, the trigger installed on the energizer will start the acquisition for the “P/S”. After that you will have to drop the mass to make the acquisition with inverse polarity.
-
Product
In-Situ Cross- Stack Laser Analyzer
-
LS25 is an in-situ analyzer for non-contact measurement of the concentration of gases. The measuring principle of the LS25 is based on the principle of single line spectroscopy (Tunable diode laser absorption spectroscopy, TDLAS). A single cross-sensitivity-free absorption line of the gas to be measured is selected in the near infrared range. A single-mode diode laser operating at room temperature scans the respective absorption line. By using an opposite receiver, the absorption caused by the sample gas is measured and from this the concentration is calculated. An automatic correction for pressure and temperature changes is possible. In addition, the transmission is displayed respectively output as a signal for preventive maintenance.
-
Product
Cross Development Tools
S12Z
-
Cosmic's tool chain for the S12Z family is part of a complete and uniform product line incorporating over 20 years of innovative design and development. Cosmic's familiar and easy to use software interface is available for all Freescale microcontrollers to simplify the migration between targets. All Cosmic products include one year of technical support and updates.
-
Product
Radar Cross Section (RCS) Measurement and Evaluation System
XRC
-
KEYCOM develops various radars for versatile applications based on its knowledge and expertise on millimeter wave and microwave technologies. KEYCOM’s product line of radars includes Radar Test Systems (RTS) to evaluate distance accuracy or output, Radar Alignment Systems (RAS) to help you adjust the alignment of radars, and Radar Cross Section (RCS) measurement systems to measure RCS of such radar targets as aircraft, ships and automobiles.
-
Product
Gas Filter Correlation CO2 Analyzer
Model N360
-
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Cross Development Tools
S12X and XGATE
-
Cosmic Software's S12X and XGATE Development Tool Suite delivers the features and performance needed to create cutting edge applications. These tools are focused on leveraging the unique benefits of the S12X microcontroller family and XGATE module, while maintaining a standardized easy to use programming environment.
-
Product
Slides (Ball & Crossed Roller)
-
Del-Tron’s linear ball slides and linear crossed roller slides offer engineers and designers the flexibility to choose the right linear slide technology for their application. Our ball slides and crossed roller slides offer several levels of precision ranging from a straight line accuracy of 0.0005” per inch of travel in our standard precision ball slides to 0.0000040” per inch of travel straight line accuracy in our high precision ball slides and crossed roller slides.
-
Product
Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer
Model T360M
-
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Correlation Analysis
-
EDM Modal Correlation Analysis allows the user to correlate two modal models; EMA and/or FEA models. Comparing the experimental data with that acquired through finite element analysis helps in validating the test results. Users can import the geometry model and mode shape data from FEA or EMA software.
-
Product
Cross Sections and Metallography
-
Rocky Mountain Laboratories, Inc.
Cross sections are prepared by mounting samples in epoxy and then grinding and polishing the mount for imaging in the optical microscope or Scanning Electron Microscopy (SEM). Valuable information from cross sectioning can include: film thicknesses, inclusions, corrosion thickness, dimensional verification, and subsurface defects. Metallographic cross sections are typically etched to reveal the microstructure. Microstructural analysis can provide information about heat treatment history, corrosion susceptibility, as well as undesirable microconstituents.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
-
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
-
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Cross Domain Security Solutions
-
Stratign’s Cross Domain Security Solutions are highly trusted, government-accredited network security components that control and, if necessary, block the flow of data between two security domains at all layers.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Cross Domain, Vendor Neutral, Integrated Service Offerings for Smarter Operations
-
Enable better than web-scale economies at a fraction of the cost.
-
Product
Crossed Roller Rail Sets
-
Del-Tron’s crossed roller rail sets (or crossed roller bearings) are compact, precision rail sets that can support and guide high loads with high accuracy, excellent repeatability, and low friction. A complete range of profiles are offered with roller diameters ranging from 1.5mm up to 6 millimeters, providing load carrying capacities to 2800 lbs. For vertical applications or applications involving high acceleration or deceleration forces you may want to consider our Anti-Creep crossed roller rail sets.
-
Product
Green Cross Line and Point Laser
Lino L2P5G
-
The Leica Lino L2P5G uses the latest green laser technology which projects clearer and crisper laser lines at exact right angles to one another. This allows for the highest accuracy of detailed interior tasks. The working range is up to 35 meters depending on the lighting conditions, and can easily be extended up to 80 meters using the laser receiver Leica RGR 200.





























