Cross Correlator
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
Product
Radar Cross Section (RCS) Measurement and Evaluation System
XRC
-
KEYCOM develops various radars for versatile applications based on its knowledge and expertise on millimeter wave and microwave technologies. KEYCOM’s product line of radars includes Radar Test Systems (RTS) to evaluate distance accuracy or output, Radar Alignment Systems (RAS) to help you adjust the alignment of radars, and Radar Cross Section (RCS) measurement systems to measure RCS of such radar targets as aircraft, ships and automobiles.
-
Product
Cross Domain Security Solutions
-
Stratign’s Cross Domain Security Solutions are highly trusted, government-accredited network security components that control and, if necessary, block the flow of data between two security domains at all layers.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model T360M
-
Teledyne Advanced Pollution Instrumentation
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.
-
Product
Crossing Type Panel Meter
ST-70W II
-
Standard Electric Works Co., Ltd
● Sensitivity Full Scale : 100 uA DC● Internal Resistance : 1100 ohm● Accuracy : Class 2.5● Case and Composition : Acrylic resin front and ABS resin case.● Color:Black case, white scale plate or yellow.● Dimension:70(L) × 70(W) × 30(D)mm● Pointer Shape:Knife or Tube-type, color in black or red.
-
Product
Crossed Roller Rail Sets
-
Del-Tron’s crossed roller rail sets (or crossed roller bearings) are compact, precision rail sets that can support and guide high loads with high accuracy, excellent repeatability, and low friction. A complete range of profiles are offered with roller diameters ranging from 1.5mm up to 6 millimeters, providing load carrying capacities to 2800 lbs. For vertical applications or applications involving high acceleration or deceleration forces you may want to consider our Anti-Creep crossed roller rail sets.
-
Product
Digital Image Correlation System for Complete 3D Warpage, Thermal Expansion, and Strain Analysis of Materials and Components in the Heating and Cooling Phase
Q-400 TCT
-
The Q-400 TCT system is designed for complete three-dimensional and highly sensitive warpage, thermal expansion measurement and strain analysis of materials and components in the heating and cooling phase. Areas from 50 mm x 70 mm down to 2 mm x 3 mm can be investigated. Measurements can be done from room temperature up to 300°C and down to -40°C. The system is specially suited for thermal expansion measurement of electronic components and is frequently used in the development and testing of complex anisotropic materials, components, and structures in electronic applications.
-
Product
Gas Filter Correlation CO2 Analyzer
Model N360
-
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
ABex Matrix Module with 86x4 or 43x8 Cross Points
ABex TM-404 Matrix
Matrix Switch Module
The ABex TM-404 is a 86×4 matrix designed as a universal connection between the test points and the measuring instrument. This can be done locally or via the ABex. The ABex TM-404 can be configured as a matrix with 4 or 8 busses. The internal matrix busses can be switched to the analog bus. The back connector allows to connect the TM-404 to the front of a Konrad PXI-501 ICT card to build a very compact ICT instrument. In addition, this combination can be used as an ABex system controller
-
Product
Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer
Model T360M
-
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
-
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
High-Speed Digital Image Correlation System
Q-450
-
The 3D High-Speed Image Correlation System Q-450 allows the full-field, non-contact and three-dimensional dynamic measurement of shape, displacements and strains on components and structures made from almost any material. Based on the digital image correlation technique, the Q-450 system is designed for full-field vibration analysis and high speed transient events. This makes it ideal for ballistics testing, fracture mechanics, shock excitations, the Hopkinson Bar test, or Impact Testing.
-
Product
Video Cross Line Generator
CL5410
-
The CL5410 can generate up to 4 lines at once and each line may be on a horizontal or vertical axis. This allows the CL5410 to replace the CL5400C, CL5404C and CL5405C and retain all of the functionality of each unit and more. The CL5410 is built on a new platform and allows a wide variety of options to be selected in the menu system. However, even with the enhanced menus, the CL5410 still has the same legendary ease of use like our previous models. That means enough buttons to change commonly used setting easily without the hassle of a menu..
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
-
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
Product
Cross Sections and Metallography
-
Rocky Mountain Laboratories, Inc.
Cross sections are prepared by mounting samples in epoxy and then grinding and polishing the mount for imaging in the optical microscope or Scanning Electron Microscopy (SEM). Valuable information from cross sectioning can include: film thicknesses, inclusions, corrosion thickness, dimensional verification, and subsurface defects. Metallographic cross sections are typically etched to reveal the microstructure. Microstructural analysis can provide information about heat treatment history, corrosion susceptibility, as well as undesirable microconstituents.
-
Product
ABex High Voltage Matrix Module with 12x4 Cross Points
ABex AM-305 HV-Matrix
Matrix Switch Module
The ABex AM-305 is a 12×4 channel high voltage switching matrix module for the Konrad ABex System. The matrix module is designed to switch voltages up to 1000 V with a current of up to 1 A.
-
Product
Live Interactive Cross Browser Testing on Real browsers
-
Perform live interactive testing of your public or local websites and web apps on real mobile and desktop browsers running on real operating system. With LambdaTest cloud platform you can accelerate your testing and make sure that your customers get pixel perfect experience across all devices, browsers, operating systems, and resolutions.
-
Product
Crossing Control Bypass Switch
XCBS-DL
-
The XCBS-DL is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the track connection harness to the designated track connection terminals. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. When in the "bypass" position, a Dummy Track Load is connected to the track wire connections in parallel with the rails and the crossing approaches are shorted, preventing unnecessary activation when track equipment is working in the crossing approach circuit. The opening of one track lead may be desired to prevent unnecessary activation with intermittent shunting on the crossing approaches close to the crossing.
-
Product
Cross Needle Meter. 1.8 - 60/144/440
MFJ-864
-
This new MFJ Cross Needle SWR/Wattmeter covers HF thru VHF 1.8 - 60MHz, 144 MHz and 440 Mhz bands. It features separate HF and VHF / UHF directional couplers, each with its own SO-239 connectors. This lets you connect your HF and VHF/UHF transceivers at the same time.
-
Product
Crossed Roller Tables(Aluminum & Steel)
-
Del-Tron’s crossed roller tables are known for their high accuracy and exceptional load carrying capabilities. Our crossed roller bearings are available in both aluminum and steel, and the perfect choice for applications where these criteria must be met. Accuracies range from 0.0001” per inch of travel straight line accuracy on our aluminum tables to 0.00008” of parallelism on our steel crossed roller tables and are capable of carrying loads in excess of 2600 lbs.
-
Product
Cross Hole Energizer P/S
CHE
-
Specially designed for small-scale cross-hole surveys, this compact hammer can be used to generate both P and S waves.The hammer can be downloaded using the steel cable and clamped to the requested depth by a pneumatic clamping system manually controlled by a lever from the surface; simply pushing up the steel cable to execute the first shot, the trigger installed on the energizer will start the acquisition for the “P/S”. After that you will have to drop the mass to make the acquisition with inverse polarity.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Green Cross Line and Point Laser
Lino L2P5G
-
The Leica Lino L2P5G uses the latest green laser technology which projects clearer and crisper laser lines at exact right angles to one another. This allows for the highest accuracy of detailed interior tasks. The working range is up to 35 meters depending on the lighting conditions, and can easily be extended up to 80 meters using the laser receiver Leica RGR 200.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Cross Domain, Vendor Neutral, Integrated Service Offerings for Smarter Operations
-
Enable better than web-scale economies at a fraction of the cost.
-
Product
Cross Cut Adhesion Tester
1540
-
The Elcometer 1540 Cross Cut Adhesion Tester is a simple instrument for quickly determining the coating adhesion of a large variety of paints up to 50µm (2 mils) thickness.
-
Product
Gas Filter Correlation Carbon Monoxide Analyzer
Model T300
-
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
ABex Matrix Module with 172x4 or 86x8 Cross Points
ABex AM-301 Matrix
Matrix Switch Module
The ABex AM-301 is a 172×4 matrix designed as a universal connection between the test points and the measuring instrument. This can be done locally or via the ABex. The ABex AM-301 can be configured as a matrix with 4 or 8 busses. The internal matrix busses can be switched to the analog bus.