Bias Current
-
Product
Handheld 2-D EM current meter with temperature and depth sensor
AEM213-D
-
AEM213-D electro-magnetic current meter with a display unit can provide the 2-D current speeds in real time. The instrument has a depth and a temperature sensor as well as the current sensor, enabling reliable current measurements at the desired depths. The compact and light-weight unit is easily portable, allowing you to use the instrument in a variety of situations.
-
Product
Analog AC Leakage Current Clamp Tester
MCL-350
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High accuracy analog display with strong taut band meter.*3 years long battery life.*Meter lock function and data output for recorder.*Filter rejection for high frequency noise
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1Z-10-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXI/PXIe Wide Current Range Matrix Module, 6x4, 2-Pole, X & Y Loop-thru
40-514-002
Matrix Switch Module
The 40-514-002 (PXI) and 42-514-002 (PXIe) are low density matrices in 6x4 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Current Probes
-
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
Product
Low TCR High Power Current Sensing Resistors, Wide Terminal Type
-
Panasonic Industrial Devices Sales Company of America
Panasonic's ERJ-D1 and ERJ-D2 Series, Low TCR High Power Current Sensing Chip Resistors, achieve high power and low TCR (±100×10–6/°C) using a wide terminal electrode structure and original materials.These Resistors are suitable for small size/high power current detection and their low TCR enables high accuracy of current detection. The ERJ-D1 Series features higher rated power at 2W in a 1020 case size while the ERJ-D2 Series features 1W in a 0612 case size. These Resistors are AEC-Q200 Compliant and offer IEC 60115-8, JIS C 5201-8 and EIAJ RC-2134B Reference Standards ensuring optimal quality and reliability.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1T24-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Inrush Current Generators for Zno Production Line
-
Shanghai Guantu Technology Co., Ltd.
Inrush Current Generator Standard: IEC61008, IEC61009, I61051/61643, ANSI C62.31, C62.33, C62.35, TU K20, K21, K44, K45, UL943Inrush Current Generator Features1. LCD screen display, built-in computer control, man-machine dialogue, easy to operate.2. Program-controlled high-voltage power supply, high voltage stability and precision3. Imported non-inductive high-power resistors are used to ensure the consistency of surge waveforms4. The main switch adopts electronic switch discharge mode, and the output polarity is automatically switched
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1L-7-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
PXI/PXIe Battery Simulator Module, 2-Channel, Simplified Current Sink, 750 V Isolation
43-752A-903
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
Split type Pulse Current Sensor
CTF-05
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
High accurate AC pulse current sensor for power demand meter.
-
Product
16 SE Or 8 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-16-4C
-
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
Product
Profiling Current Meter and Wave
SeaGuardII DCP Wave
-
The SeaGuardII DCP Wave is a 600kHz Doppler Current Profiler able to measure directional wave parameters and currents from a bottom mounted installation.The Acoustic Wave software 5759 used by the DCPS implements unique features to improve the wave measurement accuracy by optimizing the signal to noise ratio.Maximum deployment depth is 40m in normal scatter conditions. The Profiling Current Meter and Waveis available as a self-recording instrument. It can be easily integrated into a real-time system offering reliable two-way communication.
-
Product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-80
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Big CT window*AC 1A~1800A*Current measurements of main cable
-
Product
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse
T3CP30-100
-
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse.
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1B-7-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Leakage Current Tester
-
Premier's Leakage Current Tester (also known as Hipot Tester) simulates the effect of a person touching exposed metal parts of a product and detects whether or not the leakage current that would flow through the person's body remains below a safe level.
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Earth Leakage Breaker And Residual Current Device
IGR Series
-
IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62I8-4-S
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1J-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
DC Current Bias Supply
DC1000A
-
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1UN-10-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
4 (High Current) D/A Outputs (±40 VDC or +100 mA)
DA3
-
The DA3 module features 4 high-current D/A output channels with a full-scale range of ±40 VDC or ±100 mA (max). The DA3 provides either voltage or current control loop modes that are programmable for the particular application.
-
Product
ECT / ECA Eddy Current Flaw Detector
EVi
-
United Western Technologies Corp
The EVi works directly with the EddyView Family of probes and accessories. UniWest’s unmatched selection of standard and advanced display features set a new standard for flexibility of applications, ease of use, interpretation of data and overall operator accuracy. The key to the EVi’s ground-breaking performance is the display of a visual image of the surface area under inspection alongside the customary and selectable eddy current signal displays (impedance plane, A-scan or strip charts). The EVi provides a high precision, easily readable display of surface conditions enabling improved interpretation of data while giving more accurate discernment of cracks, pits, gouges and fretting.
-
Product
Device Current Waveform Analyzer, 1 GSa/s, 14/16-bit, 4 Channel
CX3324A
-
The CX3324A is a 4-channel model for engineers and researchers who need more than two channels for current waveform measurements at one time. Using a passive prove interface (CX1151A) with a current sensor (CX1101A, CX1102A, CX1103A) enables power measurements. The bandwidth and the memory depth per channel are option and can be selected from 50 MHz, 100 MHz and 200 MHz, and 16 Mpts, 64 Mpts and 256 Mpts, respectively. Upgrade products for both bandwidth and memory depth options are also available for customers who need more performance after purchasing the product. 8-channel digital channel (CX1152A) can be used with this 4-channel model so that you have more flexibility of triggering.
-
Product
Current Injectors / Relay Testing
RTS series & SC-10
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Ranges: 1A to 200A AC, Auxiliary output AC / AC+ DC, TRMS Digital metering.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1I35-2-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0300-UM
-
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.





























