Electrodes
-
Product
Starter Electrodes
-
Backed by our commitment to accurate and precise measurement, the OHAUS Starter Series of electrodes are designed to produce exact results time and time again.
-
Product
IDA Electrodes
-
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
Product
Electrodes
-
EGL electrodes have consistently raised the industry standards for reliability and performance since their introduction in 1930.To ensure rigid quality control, all phases of manufacturing are performed in-house, including emission coating, inverter welding shells with lead wires, and sealing and centering the mounts in glass envelopes.
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
Counter Electrodes
-
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
Resistivity Cell
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
Electrodes Sensor
6013
-
When selecting electrode sensors an important factor is to consider the specific characteristics of the liquid involved, the lengths required to obtain the desired control of levels, and the physical nature of the container.B/W Controls' line of electrodes has been developed to provide a practical, economical solution to almost every conceivable application and installation problem.Our electrode sensors are available in several varieties: solid rod (rigid), wire suspension, and standard gland plugs for high vibration applications. In addition, we offer custom options made per customer’s requirements.
-
Product
Electrodes, Sensors And Measurement Cells
-
Our electrodes are used for important tasks in worldwide laboratories with high demands. What began back then with the patent for pH electrodes now includes a range of several hundred different sensors: whether ultra-pure water, jam, wine, creams or drinking water – we offer the right electrode for every conceivable application. Our extensive electrode program is as diverse as the applications.
-
Product
Water Analysis Meters & Electrodes
-
Ideal for Accurate Everyday Measurements in the Laboratory
-
Product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
Resistivity Cell
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
Product
Working Electrodes for Flow Cell
-
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
Product
High-Temperature and High-PressurepH Electrodes
UltraDeg
-
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
Product
Dissolved Oxygen Meter with 3m Cable Electrode
DO 6+
-
User Customisation for user's flexibility like toggling of various modes from ppm, mg/l to % saturation, view electrode diagnosis, etc.
-
Product
Portable Conductivity/TDS Meter with Conductivity electrode
CyberScan CON 11
-
User Customizable Functions for options: Normalization Temperature, Temperature Coefficient, TDS (Total Dissolved Solids) factor, Cell constant and many more
-
Product
Dielectric Loss Tangent Testing Instruments
-
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
Product
BOMBARDING A.C. MILLIAMPERES METER
-
A Bombarding A.C. Milliamperes Meter is one of the four instruments essential for proper luminous tube processing. This instrument monitors the level of bombarder current in milliamperes that is generated by the bombarder, through the tube being processed. It is necessary to accurately monitor the current for the tubing and electrode sizes used to ensure that the right amount is applied at the appropriate time. To do otherwise may cause damage to the electrodes, fluorescent coating inside the tube and adversely affect the glass structure.
-
Product
Anti-Sulfurated Thick Film Type Resistors, Precision Type
ERJ-U2R/ERJ-U3R/ERJ-U6R Series
-
Panasonic Industrial Devices Sales Company of America
High Precision And High Resistance To Sulfurization In One Resistor!Panasonic's ERJ-U2R, ERJ-U3R, ERJ-U6R (ERJ-U*R Series) offers high precision and also provides anti-sulfurization characteristics that avoid an open circuit caused by a sulfide disconnection. High resistance to sulfurization is achieved through the use of an anti-sulfurated electrode structure and material in the manufacture of ERJ-U*R Series Resistors. AEC-Q200 Compliance and IEC 60115-8, JIS C 5201-8 and JEITA RC-2134C Reference Standards for the entire ERJ-U*R Series of High Precision, Thick Film Chip Resistors from Panasonic ensures optimal quality and reliability.
-
Product
Walking Test System Kit
PGA-710
-
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.
-
Product
Parallel systems
-
Did you know you can couple several Gill AC, Gill 12 and Weld Testers together or any combination of Gill AC, Gill 12 or Weld Tester, to give you a parallel logging multiple Potentiostat / Galvanostat / ZRA / FRA system, capable of recording from each working electrode at up to 60 readings per second. Coupling several Gill ACs or Gill 12s together gives the added abilities of the Weld tester and the ability to perform fast sweeps. Using our latest software, it has never been easier to couple instruments together to provide a Parallel System. In fact up to 32 instruments can be controlled at the same time. These instruments can either have individually enclosures or be rack mounted.
-
Product
Double Sheet / Splice Inspection
-
Leuze electronic GmbH + Co. KG
Double-sheet control sensors enable the reliable differentiation between one or more layers of very thin objects made of different materials. This allows, for example, single-layer paper sheets to be reliably pulled in or individual electrodes to be stacked for the production of a battery cell. Different operating principles, based on ultrasonics and capacitive sensors, cover the range of materials for different applications. Sensors for splice inspection detect desired and random splices in paper webs independent of the surface color and material properties.
-
Product
Pin Moisture Meter
-
Pin meters can measure all thicknesses from veneer to logs, flat boards or round and oddly shaped pieces, obtain surface and core measurements. Adding electrodes, pins (up to 7″) optimizes usage. For green, air-dried and kiln-dried lumber.
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
Bench pH/Conductivity/TDS Meter
CyberScan PC 510
-
Multi-parameter meters measures pH, Conductivity and TDS in single meter User-Customization for more accurate measurements with programmable functions like stability, electrode diagnosis - pH slope/offset/mV base value, etc.
-
Product
PH Meters
-
Shenzhen Graigar Technology Co.,Ltd.
A pH Meter is a device used for potentiometrically measuring the pH, which is either the concentration or the activity of hydrogen ions, of an aqueous solution. It usually has a glass electrode plus a calomel reference electrode, or a combination electrode.
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
Pocket Water Quality Meters
LAQUAtwin Ca-11
-
HORIBA's unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.
-
Product
Handheld Water Quality Meters
LAQUA PD220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Portable pH/mV Meter with pH electrode, temperature probe
CyberScan pH 11
-
5-point Push-Button Calibration with Auto-Buffer Recognition for quick calibration with no calibration mistakes
-
Product
Salinity Meter with Electrode
Salt 6+
-
Automatic Temperature Compensation (ATC) for the optimum accuracy under fluctuating temperatures :: Hold Function momentarily freezes reading for easy viewing and recording
-
Product
Resistivity Cell For N1413 (50 Mm Electrodes)
N1424A
Resistivity Cell
The N1424A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424A to the B2985B/87B.





























