Thermocouple Calibrators
-
Product
M0710 CALIBRATED LEAK
-
M0710 is the new ForTest® leak –certificated series for verifying leaks during automated tests. The instrument has been patented european wide.
-
Product
Thermocouple Data Logger
IM2000 Series
-
We have been offering IM2000 Series Thermocouple Data Logger with direct interfaces for various types like J / K / R / S / T / B / E etc. Loggers have built in ambient compensation. The thermocouples are most commonly used sensors for measuring temperature in process industries. These can take any form and are available in various mechanical shapes. The temperature ranges are varied.
-
Product
Torque Calibrators
-
Torque calibrators offer the ability to check torque on a manual torque wrenches, electric and impact driven torque tools.
-
Product
Calibration Software
-
EasyCal is a complete software package with features covering all aspects of calibration work and management. It is designed to reduce workload, improve efficiency, and provide the essential platform for companies looking to create and sustain an effective calibration program. The comprehensive features simplify the administration process from reminder reports through to despatch. With a familiar and intuitive user interface all operators can quickly learn and navigate through the applications. This allows fast, straightforward implementation and integration of this calibration management software.
-
Product
Temperature Calibration Equipment
-
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.
-
Product
Dose Calibrator
CRC®-55tR
-
As a combination of the new CRC®-55tR Dose Calibrator and Well Counter, the CRC-55tW dose calibrators provide advanced features with the speed and accuracy you need to measure activity and prepare doses.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Calibrated Pocket Magnetometer
M 25
-
Instruments available in 8 different, Full Scale, Gauss Ranges.
-
Product
Thermocouple (J-Type) And Temperature Probe Adapter
U1185A
-
The U1185A consists of a thermocouple bead (J-type) and a mini connector to dual banana plugs.
-
Product
High-Performance Multifunction Calibrator
5730A
-
The new 50 MHz wideband option for the 5730A High-Performance Multifunction Calibrator provides expanded wideband capabilities to self-maintaining laboratories by providing a method to calibrate the 50 MHz input of the 5790B AC Meaasurement Standard. This is accomplished by characterizing the 5730A's 50 MHz output using a precision thermal voltage converter (TVC), thus reducing uncertainties to calibrate the 5790B.
-
Product
AC Calibration Standard
1U647-001
-
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
Product
K Thermocouple Penetration Probe
TP751
-
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
Product
Multiport Calibration Assistant
S95552B
-
The S95552B software application flexibly creates and manages calibration sets for multiport measurements. This software enables you to combine multiple calibration sets with independent test ports as one calibration set with a greater number of test ports. The software also offers a way to re-calibrate using a certain set of test ports to refresh the calibration set.
-
Product
VNA Calibration Kits
-
Vector Network Analyzers are commonly used to accurately determine the RF Characteristics of microwave components. Accurate Testing of microwave circuits means eliminating measurement errors and ensuring repeatable results. This is only possible when the network analyzers can be calibrated with known and true calibration standards.
-
Product
Force Calibrating Machines
-
Morehouse Instrument Company Inc.
Morehouse Universal Calibrating Machines (UCM) are an easy to use, cost-effective, hydraulic force calibration system that lasts for generations. UCMs built in the 1950s are still operating today! The UCM can be used to calibrate both tension and compression instruments in accordance with ASTM E74, ISO 376, and other internationally recognized force standards.
-
Product
Eight-channel USB Voltage and Thermocouple DAQ
Model DI-2008
-
Includes DI-2008 instrument, WinDaq software, calibration certificate, terminal screwdriver, and USB cable (6-feet). Eight differential and isolated analog input channels. Seven bi-directional digital input ports, including: Counter input for totalizing applications, Rate input for frequency/flow/rpm applications. ChannelStretch™ channel expansion to 128 analog and 112 digital channels. Programmable voltage and thermocouple measurements per channel. 10 mV to 50 V programmable range per channel in 12 steps.
-
Product
Electromechanical Calibration for Transducer
ELCS-500
-
Jinan Testing Equipment IE Corporation
The electromechanical calibration system is specially designed for the calibration of transducers. The calibration for transducer can calibrate the load cell accuracy within +/- 0.5%.
-
Product
RTD Calibrators
-
Practical Instrument Electronics, Inc.
PIE has an RTD calibrator to fit your needs from the PIE 510B single type RTD simulator to the advanced troubleshooting capabilities of the PIE 311Plus. Have you had issues in the past where your RTD calibrator wouldn’t work with some of the instruments in your plant? Our RTD calibrators are guaranteed to be compatible with all process RTD inputs including all brands of smart temperature and multivariable transmitters, PLC input cards, DCS systems and multichannel recorders.
-
Product
Pressure Calibrators
-
Wherever you need to work and whatever pressure range you need to work with, our broad selection of tools will meet your needs. From pneumatic or hydraulic deadweight testers and test pumps to electronic deadweight testers, bench controllers, and precise analog pressure gauges, we have you covered at the bench. Going into the field? Fluke’s portable pressure calibrators – with or without pumps and intrinsically safe or not – work with gases or liquids, source and measure, power transmitters, and cover a wide range. With individually available pressure modules, our portable and bench solutions cover pressures from vacuum to 10,000 psi.
-
Product
Transducer Calibrator Systems
-
Unholtz-Dickie Calibration Systems have earned their place in industry as the standard for calibrating accelerometers and velocity transducers. The Models 660C & 680C are UD''s latest generation of automatic calibration systems, both utilizing the expanded features of the i5 based APEX SL Windows vibration control system.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
-
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30003-J
-
Breakout board for the MAX31855J digital thermocouple interface ICs by Maxim. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws. The SEN-30003 is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance (many other level shifters reduce data rates to below 500 kHz).
-
Product
Medical Device Calibration
-
Trescal provides full Medical Device Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Medical Device Calibration services can be delivered at your site or at our lab. Accreditations for our medical device calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Reference Temperature Calibrator
JOFRA™ RTC-187
-
AMETEK Sensors, Test & Calibration
RTC-187 provides high-quality temperature measurement from -45 to 180°C. The 180°C is a 25° expansion over the range of the RTC-157, and it’s now the hottest temperature available for a calibrator that also supplies cold temperatures.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Thermocouple Cable / Wire
-
Labfacility offer a wide range of thermocouple, PRT and extension cable / wire in stock for immediate despatch. Thermocouple cables are available in IEC or ANSI colour codes. Insulation types include PFA, PTFE, PVC & Fibreglass.
-
Product
Digital Load Calibrator
HS 2000
-
Jinan Testing Equipment IE Corporation
The load cell calibrator is used to calibrate the load of testing machine and hardness tester, and also can be used for force measuring. It is digital display type with high accuracy of less than +0.3%, and easy to operate
-
Product
Isolated Thermocouple Input Module
ADAM-3011
-
1000 VDC, fully isolatedConfigurable thermocouple typeFlexible DIN-rail mountingLinearized thermocouple measurementOperates from a single +24VDCTemperature range of 0 to 50°C
-
Product
Thermocouple Vacuum Gauge Tubes for Medium Vacuum
DV-6 Series
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-ST
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.