Thermocouple Calibrators
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
Electronic Calibration Module
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Thermocouple
-
This sensor uses a K-type Chromel/Alumel thermocouple and is intended for use in high-temperature, high-vibration environments. Control units and data loggers support K-type thermocouples. The sensor is short and compact to minimise its susceptibility to vibration.
-
Product
Diagonal Measurement Kit
10768A
Mechanical Calibration Kit
The Keysight 10768A Diagonal Measurement Kit is designed for use with the Keysight 5530 Laser Calibration System. It allows linear measurements to be made on the four body diagonals of a machine tool's working volume. These measurements document the machine's capability and quickly perform a complete check of volumetric positioning performance. In addition, long-term drift tests can be performed over hours or days, showing possible effects of temperature on geometry.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Thermocouple Contact, Receiver, Constantan, Type T (°C)
610113148
Thermocouple Contact (Receiver)
Primary mating contact 610113149.
-
Product
Thermocouples
-
A thermoelectric device for measuring temperature, consisting of two wires of different metals connected at two points, a voltage being developed between the two junctions in proportion to the temperature difference.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Thermocouple Contacts
-
Thermocouple contacts are manufactured from chromel or alumel alloys and are color-coded for easy identification. They are crimp terminated and easily inserted into connector modules and readily removed using a special removal tool.
-
Product
Calibration
-
Get the precision calibration tools you need to maintain the accuracy of your process, electrical, temperature, pressure, and flow measuring instruments and equipment. In addition, our in-house metrology lab will precalibrate an instrument at time of order or recalibrate equipment already owned. Our NIST-traceable calibration services and repairs help you meet your quality, regulatory, and compliance needs.
-
Product
Calibration
-
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
Product
Calibrators
-
A calibrator or process calibrator is used for basic measuring, testing and regulation techniques for setting and verifying test installations and instrumentation. PCE Instruments' calibrator products are lightweight yet made of durable materials. Our calibrator devices are easy to use and primarily handheld, though fixed installations are possible. A calibrator is valued by technicians due to its high level of accuracy and its universal range of applications.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Thermocouple Interface Amplifiers
-
Analog Devices offers specialized precision thermocouple interface amplifiers that provide a simple and effective solution for measuring thermocouple temperatures. With features such as integrated cold junction compensation and a high gain precision instrumentation amplifier, these thermocouple amplifiers provide a complete signal conditioning system in one IC package. ADI’s thermocouple amplifiers are suitable for use in diverse environments to measure a wide range of temperatures. These products will save you in cost, space, and unnecessary circuit design across a broad range of applications and industries.
-
Product
Calibrators
-
Electronic Development Labs, Inc.
Your equipment and sensors must function at optimal levels to achieve the results you want—no matter your industry. Engineered by skilled craftsmen to maximum reliability accuracy, EDL calibrators are trusted around the globe—and have been for decades. Your business relies on predictable results that consistently meet quality standards. And EDL has set the standard for calibration.
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Calibration Software
-
Calibration software is available to automate all or part of many calibration processes, manage calibration and asset data, and perform other useful tasks as well. Fluke Calibration offers a variety of market leading software applications in each of its product disciplines.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
Electronic Calibration Module
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
Product
Calibration With Traceability
-
SKF Condition Monitoring Center
SKF Quality Technology has an established global calibration network for waviness, form and vibration measurements. The QT vibration calibration system complies with the international DANAK and DPLA standards.
-
Product
Calibration Kit
N611
-
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
Product
Calibration services
-
Transcat Calibration Services offers the widest scope of ISO/IEC 17025 accreditation in the industries we serve. In fact, we are accredited for over 99% of our capabilities, and more than 95% of the calibrations we perform are accredited.
-
Product
Calibration
RF Test Equipment
-
We calibrate following types of RF test equipment:EMF test systems (frequency selective)EMF test systems (broadband)Field strength transfer standards (e.g. RefRad)Line Impedance Stabilisation Network (LISN)Cable, attenuator, couplerAntennaField Probe
-
Product
Speedometer Calibrator
-
Hypertech’s Speedometer Calibrator can correct the speedometer and odometer for tires up to 54 inches (depending on the application), and/or non-stock rear gear ratios. This new device is engineered for consumers that want the speedometer recalibration functions of the Speedometer Calibrator without the additional expense of the other tuning features. The Speedometer Calibrator comes with a USB cable and a CD containing software to enable quick updates and upgrades over the internet. For an additional charge, the Speedometer Calibrator can be upgraded to a Speedometer Calibrator via the internet to include all the Speedometer Calibrator features available for that vehicle.
-
Product
Thermocouple Kit
34307A
-
The Keysight 34307A is compatible with the Keysight 34970A Data Acquistion/Switch Unit. The 34307A can also be used with the Keysight 34401A, 34460A or 34461A, however, an external program is required to convert the voltage measurements to temperature and an ice bath or electronic reference junction must be used.
-
Product
Thermocouple Power Sensors
N8482H
Power Sensor
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.





























