Optical Fault Locators
-
Product
Optical Visual Fault Locator
SAT-3C01
-
Shaanxi Aitelong Technology Co., Ltd
SAT-3C01 Optical Visual Fault Locator is used for optical identification, fault locating of SM fiber or MM fiber, which is a basic maintenance tool of optical network, LAN, FDDI, ATM optical system, and telecom network system, suitable for field working.
-
Product
Tool, Locator, Micro Coax, Receiver
910101135
Locator Tool
Included with Crimp tool kit p/n 910101132 and kit p/n 910101131.
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
Locator Tool
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
Tool, Locator, TriPaddle, Receiver
910104146
Locator Tool
Tool, Locator, TriPaddle, Receiver (only for contact p/n #'s 610110128 Rev C+ and 610110177)
-
Product
Automated Optical Switch - PXI
Optical Switch
Add optical switching capability to your test system with Quantifi Photonics’ automated optical switches. The fast and reliable optical switch will enable automated sequential testing, saving time and streamlining your test procedures.
-
Product
Tool, Locator, Micro Power, Receiver
910104145
Locator Tool
Tool, Locator, Micro Power, Receiver.
-
Product
Broadband Optical Source - PXI
SLED 1000 Series
Optical Source
The SLED 1000 Series is a super-luminescent LED light source with high output power, large bandwidth and low spectral ripple. It comes in various wavelength models to address applications in the telecom and datacom markets.The SLED is a single-slot PXIe module and is ideal for building a customized optical testing platform that delivers reliable and repeatable results in manufacturing or R&D environments.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Hardened SFP+LR/10G-ED, SM1310/LC 20Km
SFP-XSM-LCI-20K
Optical Transceiver
Provides digital diagnostics monitoring (DDM) functionality, Wide specifications and fiber types available, Industrial standard small form-factor pluggable (SFP) package. Comes with metal enclosure for EMI, The Class 1 laser product complies with EN 60825-1, Supports plug-n-play operation.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
1x4 Optical Switch Module
81595B
Optical Switch
The plug-in module for Keysight's Lightwave Solution Platform 8163B, 8164B, 8166B is ideal for flexible system configuration in applications such as transceiver/receiver test with small foot-print or multiple passive component test with complex cascade.
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A, Hardware Interlock
40-192A-012-HI
Fault Insertion Unit
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
Product
Mini Fiber Optic, Patchcord, ITA, 36", Polymer Optic Fiber, to SMA Plug
7-413845516-036
Fiber Optic Patchcord
Mini Fiber Optic, Patchcord, ITA, 36", Polymer Optic Fiber, to SMA Plug.
-
Product
Mini Fiber Optic, Patchcord, ITA, 36", Polymer Optic Fiber, to SC
7-413845510-036
Fiber Optic Patchcord
Mini Fiber Optic, Patchcord, ITA, 36", Polymer Optic Fiber, to SC.
-
Product
Variable Optical Attenuator Module with Angled Interface
81571A
Optical Attenuator
The Keysight 81571A variable optical attenuator features lowest insertion loss and excellent wavelength flatness over a complete attenuation range of 60 dB, for characterizing optical network components for telecommunication and data communication in systems.
-
Product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
Fault Insertion Unit
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
Product
High-Power InGaAs Optical Head
81626C
Optical Power Sensor
The new 81626C high-power optical head provides a 5 mm detector area and allows flexible placement of the remote optical power meter, which is then connected to the N7749C. The 81626C accepts parallel beams with up to 4 mm diameter, standard SM fiber and MM fiber with max. 100 μm core diameter, NA ≤ 0.3. A wide choice of adapters allows input from popular fiber connector types, bare fibers or open beams. The magnetic D-shaped adapters allow rapid removal and replacement without twisting attached fibers.
-
Product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Optical Switches
Optical Source
Fast and reliable optical switches to streamline your test procedures. Can be customized with a wide range of switch configurations, fiber types and connectors.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI Single 8 Channel Optic Mux FC/PC
40-852-118
Fiber Optic Switch
The 40-852-118 8-channel multiplexer is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Product
Dual 2 Channel Fibre Optic Mux SC/PC
40-815-222
Fiber Optic Switch
Pickering PXI Fiber Optic Multiplexers connect a single channel to one of two or four channels. They are available in single or dual multiplexer configurations supporting single-mode or multi-mode fiber. A wide choice of connectors types is available. The 40-810 multiplexer connects the optical channel by redirecting the optical signal into a selected output fiber.
-
Product
PXI Dual 2x2 Insert/Bypass Switch ST
40-860-522-M
Fiber Optic Switch
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.