Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
PXI/PXIe RF Switch, Quad SPDT, Terminated, 8GHz, 50Ω, SMA
40-880B-002
Switch Module
The 40-880B-002 (PXI) and 42-880B-002 (PXIe) are quad SPDT 50Ω RF switches with 8GHz bandwidth. The 40/42-880B range has automatic termination of unused signals and are available as a dual switch in 1 slot, a quad switch in two slots or hex and octal switches in three slots.
-
Product
PXI Remote Mount Dual SP6T Multiplexer 40GHz 50, SMA-2.9, Terminated
40-785B-542-TE
Multiplexer Module
The 40-785B-542-TE is a remote mount dual 6-channel 40GHz terminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
TB-2630B , Screw Terminal, Ribbon, PXI Module Multiplexer Terminal Block
781687-01
Terminal Block
The TB-2630B provides the necessary routing to configure the PXI-2630B PXI Multiplexer Switch Module as a single, dual, or quad 1-, 2, or 4-wire multiplexer. You can directly connect the TB-2630B to the front panel I/O connectors of the PXI-2630B. The NI TB-2630B features ribbon cable headers to connect signals to the PXI Multiplexer Switch Module as well as screw terminals for trigger input and trigger output signals.
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
42-782B-541-E
Switch Module
The 40-782B-541-E (PXI) and 42-782B-541-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
Product
PXI Dual 4 to 1 RF Multiplexer 3GHz 50 Ohm MCX Terminated
40-876-102
Multiplexer Module
The 40-876-102 is a 50 Ohm 4 to 1 RF multiplexer with 2 banks in a single PXI slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-876 has been minimized by careful attention to the mechanical and electrical design.
-
Product
LXI Microwave Multiplexer, SP6T, 5-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-705
Microwave Multiplexer
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
Product
LXI Microwave Matrix, 20GHz, Single 3x3, Terminated
60-751-133-B
Matrix Switch Module
The 60-751-133-B is a single 3x3 20GHz microwave matrix with internal termination. It is part of the 60-750/751 range of LXI Microwave Switches controlled through an LXI compliant Ethernet connection. It is available in a variety of configurations and frequencies up to 20GHz (60-751). The matrix is characterized for 50 ohm applications, for 75 ohm versions please consult your local sales representative.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
42-876A-002
Multiplexer Module
The 40-876A-002 (PXI) and 42-876A-002 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
LiDAR Remote Sensing Payload Instrument
RESEPI™
-
Engineered for partners and resellers in the remote sensing industry, the Remote Sensing Payload Instrument, or RESEPI™, is a combined Dual Antenna GNSS-Aided Inertial Navigation System, datalogger, LiDAR, camera, and communications system that allows for the real-time and post-processed generation of point cloud solutions. The processing platform contains a WiFi interface, an embedded cellular modem to support RTCM corrections, data logging software, and gigabit ethernet. RESEPI™ can be used with commercially available LiDARs like Velodyne, Quanergy, Ouster, RIEGL, LIVOX, and Hesai. The device was built with the purpose of white labeling.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 40GHz, 50Ω, SMA-2.9, Remote Mount
40-785C-442-E
Multiplexer Module
The 40-785C-442-E (PXI) and 42-785C-442-E (PXIe) are dual SP4T 40GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI Remote Mount Dual SP6T Multiplexer 26.5GHz 50, SMA-2.9
40-785B-532-E
Multiplexer Module
The 40-785B-532-E is a remote mount dual 6-channel 26.5GHz unterminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
Eddy Current Data Acquisition Unit
MIZ-80iD
-
The MIZ-80iD is an all-in-one integrated eddy current instrument, probe pusher, and control system that has transformed the way eddy current data is obtained.
-
Product
Battery Extra Load Units
-
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
Product
Load Monitoring Units (LMUs)
-
Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability
-
Product
PXIe Microwave Multiplexer, Triple SP4T, 26.5 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-785C-433-E
Multiplexer Module
The 40-785C-433-E (PXI) and 42-785C-433-E (PXIe) are triple failsafe SP4T 26.5 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI Microwave Multiplexer, SP6T, 5-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-505
Microwave Multiplexer
Our 60-800-505 is a 5 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Source / Measure Unit (SMU) Modules, N6700 Power System
System
The Keysight N6780 family of source/measure units (SMUs) provide advanced features and precise control and measurements of voltage and current down to the microampere and nanoampere regions. They provide stable, glitch-free output voltage and current during high-speed load changes, fast output modulation, and high-speed measurements of both voltage and current simultaneous.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 6 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-103-E
Multiplexer Module
The 40-784B-103-E (PXI) and 42-784B-103-E (PXIe) are triple failsafe SP4T 6 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
Vibration Control, Monitoring and Diagnostics System for Hydraulic Units
-
Stationary system for vibration control, monitoring and diagnostics of hydraulic units is used for constant technological and safety control, diagnostics of vibrational and mechanical parameters of hydraulic units and auxiliary equipment of hydroelectric power stations in accordance with the applicable requirements.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-785C-473-E
Multiplexer Module
The 40-785C-473-E (PXI) and 42-785C-473-E (PXIe) are triple failsafe SP4T 67 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Remote Plasma Sources
-
Equip your manufacturing and abatement processes with high functionality and exceptional reliability. Customize your chemistry. Expand your operating range. Deliver higher process rates. Advanced Energy’s remote plasma sources offer sophisticated options in streamlined designs.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 26.5GHz, 50Ω, SMA, Remote Mount
40-785C-433-E
Multiplexer Module
The 40-785C-433-E (PXI) and 42-785C-433-E (PXIe) are triple SP4T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
LXI Microwave Multiplexer, SP6T, 10-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-510
Multiplexer Module
Our 60-800-510 is a 10 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Terminal Test Kit (92 Pcs)
3601C
-
Peaceful Thriving Enterprise Co Ltd
*Total: 92 pcs*Alligator clip x 2 pcs*Testing probe x 2 pcs*Flat terminal x 48 pcs*Testing needle x 4 pcs*1 to 2 connector x 2 pcs*Round terminal x 24 pcs*5K variable resistor x 2 pcs*Polarity tester/stroboscope x 2 pcs*SRS air bag replacement connector x 2 pcs*Male / Female to Male / Female Extension Wire x 4 pcs
-
Product
PPID-2000 Photosynthetic Photon Intensity Distribution Test Unit
-
Hangzhou Everfine Photo-E-Info Co., LTD
It is mainly used for testing plant lighting products. With the EVERFINE GO-R5000 goniophotometer system, it can realize the measurement of plant photosynthetic photon intensity distribution (μmol/s/sr) in the whole space. In addition, the device can also realize the test of photosynthetic photon flux, far red light photon flux, photosynthetic radiation efficiency and other parameters, referring to DLC, ASABE, DIN, GB, CQC and CSA related international plant lighting standards .
-
Product
PXI/PXIe Microwave Relay, Dual SPDT, 2.5 GHz, 75 Ω, 1.6/5.6, Remote Mount, Failsafe
42-780B-752-E
Relay
The 40-780B-752-E (PXI) and 42-780B-752-E (PXIe) are dual failsafe SPDT 2.5 GHz 75 Ω unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP10T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-122-TE
Multiplexer Module
The 40-788-122-TE (PXI) and 42-788-122-TE (PXIe) are dual failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
LXI Microwave Multiplexer, SP4T, 3-Bank, 26.5GHz, 50Ω, SMA, Terminated
60-803-303
Multiplexer Module
High performance RF multiplexer suitable for switching microwave signals up to 26.5GHz with automatic termination of unused signals
-
Product
NI-9970, 2-Position, Spring Terminal Connector Plug, 3.5 mm Pitch (Qty 4)
787005-01
-
2-Position, Spring Terminal Connector Plug, 3.5 mm Pitch (Qty 4)
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 18GHz, 50Ω, SMA, Remote Mount
40-784B-023-E
Multiplexer Module
The 40-784B-023-E (PXI) and 42-784B-023-E (PXIe) are triple SP6T 18GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.




























